Comparison of Postoperative Sore Throat and Hoarseness Between Two Types of Double-Lumen Endobronchial Tubes: A Randomized Controlled Trial

被引:24
|
作者
Jeon, Joonpyo [1 ]
Lee, Kusang [1 ]
Ahn, Guyeon [1 ]
Lee, Jingyoung [1 ]
Hwang, Wonjung [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Dept Anesthesiol, Seoul 137701, South Korea
关键词
intubation; postoperative complications; sore throat; hoarseness; double lumen tubes; thoracic anesthesia; TRACHEAL INTUBATION; SURGERY; COMPLAINTS; SIZE;
D O I
10.1053/j.jvca.2014.05.028
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: Two types of material are used to manufacture double-lumen endobronchial tubes (DLTs): Polyvinylchloride (PVC) and silicon. PVC DLTs (Broncho-Cath) and silicon DLTs (Silbroncho) not only differ in material, but also subtly differ in structure. The goal of this study was to determine whether the incidences of postoperative sore throat and hoarseness differed between PVC DLTs and silicon DLTs. Design: Prospective, single-blind, balanced (1:1), randomized, controlled trial. Setting: Single university hospital. Participants: Sixty ASA I-II patients, aged 20 to 65 years, scheduled for thoracoscopic pulmonary lobectomy. Interventions: Patients were randomized into the Broncho-cath group (group B, n = 30) and the Silbroncho group (group S. n = 30). Intubation was performed with DLT according to the allocated group by an anesthesiologist. Measurements and Main Results: The incidence of sore throat and hoarseness was evaluated at 1 hour and 24 hours after DLT extubation. The intensity of sore throat was assessed by visual analog scale (VAS < 0-10) at 1, 2, 4, 12, and 24 hours after DLT extubation. The incidence of sore throat was significantly lower in group S compared with that in group B at 1 h (30% v 66.7%, p = 0.018) and 24 hours (10% v 43.3%, p = 0.014). No significant difference was observed in the incidence of hoarseness between the 2 groups. The VAS scores for sore throat in group B were significantly higher than those in group S throughout the study (p < 0.05). Conclusions: The use of silicon DLTs resulted in a lower incidence of postoperative sore throat than did the use of PVC DLTs. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:121 / 125
页数:5
相关论文
共 50 条
  • [21] A randomised controlled trial comparing the GlideScope® and the Macintosh laryngoscope for double-lumen endobronchial intubation
    Russell, T.
    Slinger, P.
    Roscoe, A.
    McRae, K.
    Van Rensburg, A.
    ANAESTHESIA, 2013, 68 (12) : 1253 - 1258
  • [22] The effect of benzydamine hydrochloride on preventing postoperative sore throat after total thyroidectomy: a randomized-controlled trial
    Kim, Doyeon
    Jeong, Heejoon
    Kwon, Jihye
    Kang, Sehee
    Han, Bobae
    Lee, Eun Kyung
    Lee, Sangmin M.
    Choi, Ji Won
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (08): : 934 - 942
  • [23] Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial
    Seo, Jeong-Hwa
    Yoon, Susie
    Min, Se-Hee
    Row, Hyung Sang
    Bahk, Jae-Hyon
    PLOS ONE, 2019, 14 (01):
  • [24] Preoperative ketamine nebulization attenuates the incidence and severity of postoperative sore throat: A randomized controlled clinical trial
    Thomas, Derlin
    Bejoy, Revathy
    Zabrin, Nimeeliya
    Beevi, Suhura
    SAUDI JOURNAL OF ANAESTHESIA, 2018, 12 (03) : 440 - 445
  • [25] Application of triamcinolone acetonide paste to the endotracheal tube reduces postoperative sore throat: a randomized controlled trial
    Park, Sun Young
    Kim, Sang Hyun
    Lee, Se Jin
    Chae, Won Seok
    Jin, Hee Cheol
    Lee, Jeong Seok
    Kim, Soon Im
    Hwang, Kyung Ho
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (05): : 436 - 442
  • [26] Comparison between I-gel® and endotracheal intubation in terms of the incidence of postoperative sore throat following thyroid surgery: a randomized observational trial
    Ning, Meng
    Zhong, Weiwei
    Li, Jin
    Wang, Tingting
    Lu, Yao
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2022, 14 (01): : 373 - 380
  • [27] Comparison of conventional and fibreoptic-guided advance of left-sided double-lumen tube during endobronchial intubation A randomised controlled trial
    Park, Jin-Woo
    Jo, Ji H.
    Park, Jin H.
    Bae, Yu K.
    Park, Seong-Joo
    Cho, Sung-Woo
    Han, Sung-Hee
    Kim, Jin-Hee
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (06) : 466 - 473
  • [28] Controlled comparison between betamethasone gel and lidocaine jelly applied over endotracheal tube in reducing postoperative sore throat, cough, and hoarseness of voice
    Upadhyay, Nitish
    Gupta, Radha
    Prakash, Sukirti
    Bhalla, Swaran
    INDIAN ANAESTHETISTS FORUM, 2018, 19 (02): : 65 - 72
  • [29] The Flex-Tip™ tracheal tube does not reduce the incidence of postoperative sore throat: a randomized controlled trial
    Turkstra, Timothy P.
    Smitheram, Amanda K.
    Alabdulhadi, Osama
    Youssef, Hesham
    Jones, Philip M.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2011, 58 (12): : 1090 - 1096
  • [30] Effects of benzydamine hydrochloride on postoperative sore throat after extubation in children: a randomized controlled trial
    Yhim, Hyung-Been
    Yoon, Soo-Hyuk
    Jang, Young-Eun
    Lee, Ji-Hyun
    Kim, Eun-Hee
    Kim, Jin-Tae
    Kim, Hee-Soo
    BMC ANESTHESIOLOGY, 2020, 20 (01)