A Monte Carlo Study on the Spatial Resolution of Uncollimated β Particles with Silicon-based Detectors for Autoradiography

被引:1
|
作者
Cabello, J. [1 ]
Wells, K. [1 ]
机构
[1] Univ Surrey, Fac Engn & Phys Sci, Ctr Vis Speech & Signal Proc, Guildford GU2 7XH, Surrey, England
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
Digital Autoradiography; Spatial Resolution; CMOS; CCD; Geant4; CHARGE DIFFUSION; DIGITAL AUTORADIOGRAPHY; CCD;
D O I
10.1109/NSSMIC.2009.5401625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional Autoradiography is an imaging modality used in life sciences where thin ex-vivo tissue sections are placed in direct contact with autoradiographic film. High resolution autoradiograms can be obtained using low energy radioisotopes, such as 3 H where an intrinsic 0.1-1 mu m spatial resolution can be achieved due to limited beta- path length. Several digital alternatives have been presented in recent years to replace conventional film as the imaging medium, but the spatial resolution of film remains unmatched. Although silicon-based imaging technologies have demonstrated higher sensitivity compared to conventional film, the main issue that remains is spatial resolution. We address this here with an investigation into the design parameters that impact on spatial resolution when imaging uncollimated beta- found in Autoradiography. The study considers Monte Carlo simulation of the energy deposition process, the charge diffusion process in silicon and the detector noise, and this is applied to a range of radioisotope beta energies typically used in Autoradiography. Finally an optimal detector geometry to obtain the best possible spatial resolution for a specific technology and a specific radioisotope is suggested.
引用
收藏
页码:2877 / +
页数:2
相关论文
共 40 条
  • [21] Monte Carlo simulation of the system performance of a long axial field-of-view PET based on monolithic LYSO detectors
    Abi-Akl, Maya
    Dadgar, Meysam
    Toufique, Yassine
    Bouhali, Othmane
    Vandenberghe, Stefaan
    EJNMMI PHYSICS, 2023, 10 (01)
  • [22] A MONTE-CARLO CODE TO SIMULATE THE EFFECT OF FAST SECONDARY ELECTRONS ON K(AB) FACTORS AND SPATIAL-RESOLUTION IN THE TEM
    GAUVIN, R
    LESPERANCE, G
    JOURNAL OF MICROSCOPY-OXFORD, 1992, 168 : 153 - 167
  • [23] Low-temperature electron transport in [110] and [100] silicon nanowires: a DFT-Monte Carlo study
    Shiri, Daryoush
    Nekovei, Reza
    Verma, Amit
    FRONTIERS IN NANOTECHNOLOGY, 2024, 6
  • [24] Polaroid-PET: a PET scanner with detectors fitted with Polaroid for filtering unpolarized optical photons-a Monte Carlo simulation study
    Sanaat, Amirhossein
    Ashrafi-Belgabad, Aydin
    Zaidi, Habib
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [25] Improving the spatial resolution in CZT detectors using charge sharing effect and transient signal analysis: Simulation study
    Zheng, Xiaoqing
    Cheng, Zeng
    Deen, M. Jamal
    Peng, Hao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 808 : 60 - 70
  • [26] A Novel Iterative Image Reconstruction Method for High-Resolution PET Imaging with a Monte Carlo Based Positron Range Model
    Fu, Lin
    Qi, Jinyi
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2884 - 2887
  • [27] Monte Carlo simulation of spatial resolution of lens-coupled LYSO scintillator for intense pulsed gamma-ray imaging system with large field of view
    Li, Guoguang
    Sheng, Liang
    Duan, Baojun
    Li, Yang
    Hei, Dongwei
    Xing, Qingzi
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (07) : 2650 - 2658
  • [28] Coronary atherosclerotic plaque characterization with silicon-based photon-counting computed tomography (CT): A simulation-based feasibility study
    Li, Mengzhou
    Wu, Mingye
    Pack, Jed
    Wu, Pengwei
    Yan, Pingkun
    De Man, Bruno
    Wang, Adam
    Nieman, Koen
    Wang, Ge
    MEDICAL PHYSICS, 2024, : 8725 - 8741
  • [29] Evaluation of Improved Imaging Properties with Tungsten-Based Parallel-Hole Collimators: A Monte Carlo Study
    Islamian, Jalil Pirayesh
    Ljungberg, Michael
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2024, 23 (02) : 95 - 102
  • [30] High-resolution liquid-crystal-based spatial light modulator with a thin crystalline silicon photosubstrate structure
    Sayyah, K
    Au, A
    Efron, U
    Yamazaki, T
    APPLIED OPTICS, 1996, 35 (29): : 5761 - 5764