Automatic image analyser to assess retinal vessel calibre (ALTAIR). A new tool to evaluate the thickness, area and length of the vessels of the retina

被引:9
作者
Maderuelo-Fernandez, Jose A. [1 ]
Garcia-Garcia, Angel [1 ]
Chamoso, Pablo [2 ]
Recio-Rodriguez, Jose, I [1 ,3 ]
Rodriguez-Gonzalez, Sara [2 ]
Patino-Alonso, Maria C. [1 ,4 ]
Rodriguez-Sanchez, Emiliano [1 ,5 ]
Corchado-Rodriguez, Juan M. [2 ]
Gomez-Marcos, Manuel A. [1 ,5 ]
Garcia-Ortiz, Luis [1 ,6 ]
机构
[1] Hlth Serv Castilla & Leon SACyL, Primary Hlth Care Res Unit Salamanca APISAL, Inst Biomed Res Salamanca IBSAL, Salamanca, Spain
[2] Univ Salamanca USAL, Salamanca Inst Biomed Res IBSAL, Comp & Automat Dept, BISITE Res Grp, Salamanca, Spain
[3] Univ Salamanca USAL, Dept Nurse & Physiotherapy, Salamanca, Spain
[4] Univ Salamanca USAL, Dept Stat, Salamanca, Spain
[5] Univ Salamanca USAL, Dept Med, Salamanca, Spain
[6] Univ Salamanca USAL, Dept Biomed & Diagnost Sci, Salamanca, Spain
关键词
Reproducibility of results; Image processing; Computer-assisted; Retinal vessels; Vascular stiffness; Cardiovascular diseases; INTIMA-MEDIA THICKNESS; TARGET ORGAN DAMAGE; ATHEROSCLEROSIS RISK; CARDIOVASCULAR RISK; EUROPEAN-SOCIETY; VASCULAR CALIBER; MICROVASCULAR ABNORMALITIES; ARTERIOLAR DIAMETER; METABOLIC SYNDROME; BLOOD-PRESSURE;
D O I
10.1016/j.ijmedinf.2020.104090
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background and objectives: The examination of the fundus allows to evaluate retinal the microcirculation in vivo. We assess the reliability and validity of ALTAIR software, and to evaluate its clinical relevance by the association of thickness, area and length of the retinal vessels with other measures of vascular structure and function, target organ damage and cardiovascular risk. Methods: Cross-sectional study involving a total of 250 subjects aged 62 +/- 9 years, 51 % males. In a random subsample of 60 subjects (118 retinographies), we estimated the intraobserver, interobserver and interdevice intraclass correlation coefficients (ICC) of the measurements of retinal vascular thickness, area and length in 3 concentric circles. Concurrent validity was assessed with all 250 subjects (495 retinographies), analysing the relationship to age, blood pressure, target organ damage, vascular structure and function, and cardiovascular risk. Results: Of the sample, 69 % were diagnosed with hypertension and 17 % with diabetes. Intraobserver ICC ranged from 0.640 for venous length to 0.906 for arterial area. Interobserver ICC ranged from 0.809 for arterial length to 0.916 for venous area, and interdevice ICC for arteriovenous ratio (AVR) was 0.887, thickness of arteries 0.590 and vein thickness 0.677. We found a moderate correlation between retinal vascular parameters and vascular structure and function, and target organ damage. In multiple linear regression analysis, the association with blood pressure, albumin/creatinine ratio, carotid intima-media thickness and cardiovascular risk is maintained. Conclusion: The ALTAIR tool has been useful for analysing the thickness, area and length of retinal vessels, with adequate reliability and a concomitant association of retinal vessel measurements with other cardiovascular parameters and cardiovascular risk. Therefore, in addition to thickness, the area and length of retinal vessels could also play a role in the prediction of cardiovascular risk.
引用
收藏
页数:10
相关论文
共 1 条
  • [1] Validation of the automatic image analyser to assess retinal vessel calibre (ALTAIR): a prospective study protocol
    Garcia-Ortiz, Luis
    Gomez-Marcos, Manuel A.
    Recio-Rodriguez, Jose I.
    Maderuelo-Fernandez, Jose A.
    Chamoso-Santos, Pablo
    Rodriguez-Gonzalez, Sara
    de Paz-Santana, Juan F.
    Merchan-Cifuentes, Miguel A.
    Corchado-Rodriguez, Juan M.
    BMJ OPEN, 2014, 4 (12):