Evaluation of potential factors affecting the measurement of cerebrovascular reactivity by near-infrared spectroscopy

被引:27
作者
Totaro, R
Barattelli, G
Quaresima, V [1 ]
Carolei, A
Ferrari, M
机构
[1] Univ Aquila, Dipartimento Sci & Tecnol Biomed, I-67100 Laquila, Italy
[2] Univ Aquila, Dipartimento Med Interna & Sanita Pubbl, I-67100 Laquila, Italy
关键词
carbon dioxide; cerebrovascular reactivity; near-infrared spectroscopy; transcranial Doppler sonography;
D O I
10.1042/CS19980122
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
1. Near-infrared (IR) spectroscopy is based on the relative transparency of skin, skull and brain to the light in the near-IR region (700-1100 nm) and on the oxygen-dependent tissue absorption changes of haemoglobin. 2. We evaluated the most relevant factors (reproducibility, venous return, age and sex) that might affect reliability of near-IR spectroscopy to test CO2 cerebrovascular reactivity. 3. Thirty-four healthy volunteers were enrolled in the study. The protocol consisted of a 3-min baseline, a 3-min hypercapnia (5% CO2 in air) and a 2-min recovery. Transcranial Doppler sonography measurements were simultaneously performed. The CO2 reactivity test was repeated on 27 subjects after 1 h to assess reproducibility. CO2 reactivity was also evaluated at different body positions (supine, 35 degrees Trendelenburg and 35 degrees reverse Trendelenburg), and over a gradual increase of the inspired CO2. 4. Changes in near-IR spectroscopy and transcranial Doppler sonography parameters were significantly correlated with variations of end-tidal CO2 (P < 0.005). A significant correlation between the reactivity indexes of near-IR spectroscopy parameters and flow velocity was also found (P < 0.01). A high reproducibility was also found for deoxyhaemoglobin (r(i) = 0.76), oxyhaemoglobin (r(i) = 0.68) and flow velocity (r(i) = 0.60) reactivity indexes. No significant differences between the reactivity indexes of different body positions were found (P > 0.05). The reactivity index of oxyhaemoglobin and deoxyhaemoglobin decreased (P < 0.05) and increased (P < 0.01) with age respectively. 5. We found that near-IR spectroscopy is a reliable and reproducible method for the evaluation of cerebrovascular reactivity and might be considered, after appropriate validation, for the assessment of patients with cerebrovascular disease.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 39 条
[11]  
Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
[12]   PATTERNS OF CEREBROVASCULAR REACTIVITY IN PATIENTS WITH UNILATERAL ASYMPTOMATIC CAROTID-ARTERY STENOSIS [J].
FURST, H ;
HARTL, WH ;
JANSSEN, I .
STROKE, 1994, 25 (06) :1193-1200
[13]   NEAR-INFRARED SPECTROSCOPY IN ADULTS - EFFECTS OF EXTRACRANIAL ISCHEMIA AND INTRACRANIAL HYPOXIA ON ESTIMATION OF CEREBRAL OXYGENATION [J].
GERMON, TJ ;
KANE, NM ;
MANARA, AR ;
NELSON, RJ .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (04) :503-506
[14]  
Grolimund P, 1986, TRANSCRANIAL DOPPLER, P10
[15]   NEAR-INFRARED SPECTROSCOPY IN ADULTS - DOES THE INVOS 3100 REALLY MEASURE INTRACEREBRAL OXYGENATION [J].
HARRIS, DNF ;
BAILEY, SM .
ANAESTHESIA, 1993, 48 (08) :694-696
[16]   AGE DEPENDENCY OF CHANGES IN CEREBRAL HEMOGLOBIN OXYGENATION DURING BRAIN ACTIVATION - A NEAR-INFRARED SPECTROSCOPY STUDY [J].
HOCK, C ;
MULLERSPAHN, F ;
SCHUHHOFER, S ;
HOFMANN, M ;
DIRNAGL, U ;
VILLRINGER, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1995, 15 (06) :1103-1108
[17]   INDUCED RESPONSE TO HYPERCAPNIA IN THE 2-COMPARTMENT TOTAL CEREBRAL BLOOD-VOLUME - INFLUENCE ON BRAIN VASCULAR RESERVE AND FLOW EFFICIENCY [J].
KEYEUX, A ;
OCHRYMOWICZBEMELMANS, D ;
CHARLIER, AA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1995, 15 (06) :1121-1131
[18]   Use of near-infrared spectroscopy in the adult [J].
Kirkpatrick, PJ .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES B-BIOLOGICAL SCIENCES, 1997, 352 (1354) :701-705
[19]   COURSE OF CAROTID-ARTERY OCCLUSIONS WITH IMPAIRED CEREBROVASCULAR REACTIVITY [J].
KLEISER, B ;
WIDDER, B .
STROKE, 1992, 23 (02) :171-174
[20]   Internal and external carotid contributions to near-infrared spectroscopy during carotid endarterectomy [J].
Lam, JMK ;
Smielewski, P ;
AlRawi, P ;
Griffiths, P ;
Pickard, JD ;
Kirkpatrick, PJ .
STROKE, 1997, 28 (05) :906-911