The outdoor air ventilation rate in high-rise residences employing room air conditioners

被引:34
作者
Lin, ZP [1 ]
Deng, SM [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
关键词
ventilation; CO2; level; residences; room air conditioner; sleeping environment;
D O I
10.1016/j.buildenv.2003.07.001
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ventilation is important because it affects indoor environmental conditions, including air pollutant concentrations that may modify the health of the occupants of a building, or their perceptions and comfort. This paper reports, first of all, on field studies monitoring indoor overnight CO2 levels and outdoor ventilation rates in bedrooms employing room air conditioners (RACs), so the current situation of ventilation in actual high-rise residential buildings in Hong Kong can be appreciated. This is followed by a report of the results of laboratory experiments where two typical RACs were used in an examination of outdoor air ventilation characteristics in rooms employing RACs. The results of field studies showed that the outdoor ventilation rates in the measured bedrooms equipped with RACs in high-rise residential buildings in Hong Kong could not meet the ventilation requirement specified in the ASHRAE standard 62-2001 even if there was only one occupant in a bedroom. Although the use of a window-type air conditioner (WRAC) may provide a higher outdoor ventilation rate than the use of a split-type air conditioner (SRAC), this may be ascribed to the fact there is more natural infiltration when a WRAC is used. The ventilation damper currently available in a WRAC does not significantly affect the outdoor ventilation rate. Therefore, such a damper cannot be expected to provide the ventilation rate as required by a ventilation code and its intended function of controlling ventilation is limited. In addition, the air exhausted from indoors to outdoors through the ventilation outlet in a WRAC is air that has just been cooled by the cooling coil (evaporator). This is unreasonable, because exhausting just-cooled and dehumidified air is a waste of energy. Therefore, an improved design for a WRAC has been suggested. Finally, the outdoor ventilation requirement for bedrooms at nighttime, when occupants are asleep, is discussed. A new ventilation rate of 3.01/s per person for the sleeping environment in high-rise residential buildings is proposed. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1389 / 1399
页数:11
相关论文
共 23 条
[1]  
ACGIH, 1995, AM C GOV IND HYG CIN
[2]  
American Society for Testing and Materials ASTM G32, 1998, ANN BOOK ASTM STAND
[3]  
[Anonymous], 2010, Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials, P1
[4]  
ASHRAE, 2001, 622001 ASHRAE
[5]  
*ASHRAE, 1999, 622P ASHRAE
[6]  
*ASHRAE, 2001, 551992R ANSI ASHRAE
[7]  
BERG-MUNCH B, 1986, Environment International, V12, P195, DOI 10.1016/0160-4120(86)90030-9
[8]   VENTILATION REQUIREMENTS IN BUILDINGS .1. CONTROL OF OCCUPANCY ODOR AND TOBACCO-SMOKE ODOR [J].
CAIN, WS ;
LEADERER, BP ;
ISSEROFF, R ;
BERGLUND, LG ;
HUEY, RJ ;
LIPSITT, ED ;
PERLMAN, D .
ATMOSPHERIC ENVIRONMENT, 1983, 17 (06) :1183-1197
[9]  
CHOW TT, 2001, INT J HOUSING SCI IT, V25, P13
[10]  
Fanger P.O., 1983, P ENG FDN C MAN ATM, P45