iPhone-based Pupillometry: A Novel Approach for Assessing the Pupillary Light Reflex

被引:45
作者
McAnany, J. Jason [1 ,2 ]
Smith, Brandon M. [3 ]
Garland, Amy [4 ]
Kagen, Steven L. [4 ]
机构
[1] Univ Illinois, Dept Ophthalmol & Visual Sci, Chicago, IL USA
[2] Univ Illinois, Dept Bioengn, Chicago, IL USA
[3] Univ Wisconsin, Dept Comp Sci, 1210 W Dayton St, Madison, WI 53706 USA
[4] KagenAir LLC, Appleton, WI 54911 USA
基金
美国国家卫生研究院;
关键词
AUTONOMIC NERVOUS-SYSTEM; INFRARED PUPILLOMETRY; DIABETIC-RETINOPATHY; ALZHEIMERS-DISEASE; RESPONSES; NEUROPATHY; AGREEMENT; STIMULUS; CONE;
D O I
10.1097/OPX.0000000000001289
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE: The response of the pupil to a flash of light, the pupillary light reflex (PLR), is an important measure in optometry and in other fields of medicine that is typically evaluated by qualitative observation. Here we describe a simple, portable, iPhone-based pupillometer that quantifies the PLR in real time. PURPOSES: The purposes of this study were to describe a novel application that records the PLR and to compare its technical capabilities with a laboratory-based infrared (IR) camera system. METHODS: Pupil sizes were measured from 15 visually normal subjects (age, 19 to 65 years) using an IR camera system and the Sensitometer test. This test elicits pupillary constriction using the iPhone flash, records pupil size using the camera, and provides measurements in real time. Simultaneous recordings were obtained with the Sensitometer test and IR camera, and two measures were calculated: (1) dark-adapted steady-state pupil size and (2) minimum pupil size after the flash. The PLR was defined as the difference between these two measures. Pupil size was also recorded during the redilation phase after the flash. Bland-Altman analysis was used to assess the limits of agreement between the two methods. RESULTS: Statistically significant correlations between the IR and Sensitometer test measures were found for the PLR (r= 0.91, P< .001) and redilation size (r= 0.65, P= .03). Bland-Altman analysis indicated a mean PLR difference of 6% between these two methods. The PLR limit of agreement was 14%, indicating that 95% of subjects are expected to have IR and Sensitometer test measurements that differ by 14% or less. Bland-Altman analysis indicated a mean redilation size difference of 1% between the two methods; the limit of agreement was 5%. CONCLUSIONS: There is excellent agreement between pupil responses recorded using the Sensitometer test and IR camera. The Sensitometer test provides a highly promising approach for simple, portable, inexpensive pupillary measurements. Copyright (C) 2018 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the American Academy of Optometry.
引用
收藏
页码:953 / 958
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 2000, J NEUROTRAUM, V17, P583, DOI 10.1089/neu.2000.17.583
[2]   Latency of the pupil light reflex: Sample rate, stimulus intensity, and variation in normal subjects [J].
Bergamin, O ;
Kardon, RH .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (04) :1546-1554
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Pupillometric Evaluation of the Dynamics of the Pupillary Response to a Brief Light Stimulus in Healthy Subjects [J].
Bremner, Fion D. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (11) :7343-7347
[6]   Infrared Video Pupillography Coupled with Smart Phone LED for Measurement of Pupillary Light Reflex [J].
Chang, Lily Yu-Li ;
Turuwhenua, Jason ;
Qu, Tian Yuan ;
Black, Joanna M. ;
Acosta, Monica L. .
FRONTIERS IN INTEGRATIVE NEUROSCIENCE, 2017, 11
[7]   Two-color pupillometry in enhanced S-cone syndrome caused by NR2E3 mutations [J].
Collison, Frederick T. ;
Park, Jason C. ;
Fishman, Gerald A. ;
Stone, Edwin M. ;
McAnany, J. Jason .
DOCUMENTA OPHTHALMOLOGICA, 2016, 132 (03) :157-166
[8]   Full-Field Pupillary Light Responses, Luminance Thresholds, and Light Discomfort Thresholds in CEP290 Leber Congenital Amaurosis Patients [J].
Collison, Frederick T. ;
Park, Jason C. ;
Fishman, Gerald A. ;
McAnany, J. Jason ;
Stone, Edwin M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (12) :7130-7136
[9]   Monitoring depth of anesthesia: from consciousness to nociception. A window on subcortical brain activity [J].
Constant, Isabelle ;
Sabourdin, Nada .
PEDIATRIC ANESTHESIA, 2015, 25 (01) :73-82
[10]   The post-illumination pupil response of melanopsin-expressing intrinsically photosensitive retinal ganglion cells in diabetes [J].
Feigl, Beatrix ;
Zele, Andrew J. ;
Fader, Samantha M. ;
Howes, Annelisa N. ;
Hughes, Catherine E. ;
Jones, Kris A. ;
Jones, Rawlyn .
ACTA OPHTHALMOLOGICA, 2012, 90 (03) :e230-e234