Focused ultrasound transducer for thermal treatment

被引:8
作者
Umemura, Shin-ichiro [1 ]
机构
[1] Tohoku Univ, Grad Sch Biomed Engn, Sendai, Miyagi 9808579, Japan
关键词
Air-backed transducer; focused array transducer; matching layer; ultrasound; VORTEX PHASED-ARRAY; PROSTATE-CANCER; SURGERY; HYPERTHERMIA; DESIGN; TISSUE; SYSTEM;
D O I
10.3109/02656736.2015.1008059
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Air-backed transducers have been employed for thermal ultrasonic treatment including both ablation and hyperthermia because the power efficiency rather than the bandwidth is a main concern, unlike a typical imaging transducer working in a pulse mode. The characteristic of an air-backed piezoelectric transducer with a matching layer is analysed, and the role and choice of the matching layer is discussed. An element size of a focused array transducer, appropriate for such thermal treatment, is then estimated, and the characteristic of a piezoceramic transducer element of such a size was numerically analysed using a finite element code. The characteristic of a piezocomposite transducer element is also numerically analysed and its suitability to such a therapeutic array transducer is discussed.
引用
收藏
页码:216 / 221
页数:6
相关论文
共 20 条
[1]   CONCENTRIC-RING AND SECTOR-VORTEX PHASED-ARRAY APPLICATORS FOR ULTRASOUND HYPERTHERMIA [J].
CAIN, CA ;
UMEMURA, S .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :542-551
[2]   A hemisphere array for non-invasive ultrasound brain therapy and surgery [J].
Clement, GT ;
Sun, J ;
Giesecke, T ;
Hynynen, K .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12) :3707-3719
[3]   FOCUSED US SYSTEM FOR MR IMAGING-GUIDED TUMOR ABLATION [J].
CLINE, HE ;
HYNYNEN, K ;
WATKINS, RD ;
ADAMS, WJ ;
SCHENCK, JF ;
ETTINGER, RH ;
FREUND, WR ;
VETRO, JP ;
JOLESZ, FA .
RADIOLOGY, 1995, 194 (03) :731-737
[4]   A 256-element ultrasonic phased array system for the treatment of large volumes of deep seated tissue [J].
Daum, DR ;
Hynynen, K .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (05) :1254-1268
[5]  
De Jong N., 1985, Ultrasonics, V23, P176, DOI 10.1016/0041-624X(85)90027-7
[6]   Analytical and numerical calculations of optimum design frequency for focused ultrasound therapy and acoustic radiation force [J].
Ergun, A. Sanli .
ULTRASONICS, 2011, 51 (07) :786-794
[7]  
FOSTER RS, 1993, EUR UROL, V23, P330
[8]   Mid-term outcome of magnetic resonance-guided focused ultrasound surgery for uterine myomas: From six to twelve months after volume reduction [J].
Funaki, Kaoru ;
Fukunishi, Hidenobu ;
Funaki, Tsuyoshi ;
Kawakami, Chihiro .
JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2007, 14 (05) :616-621
[9]  
GELET A, 1993, EUR UROL, V23, P44
[10]   OPTIMUM ACOUSTIC FREQUENCY FOR FOCUSED ULTRASOUND SURGERY [J].
HILL, CR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03) :271-277