A Low-Cost Approach to the Skin Effect Compensation in Cylindrical Shunts

被引:3
作者
Faifer, Marco [1 ]
Ferrero, Roberto [2 ]
Laurano, Christian [1 ]
Ottoboni, Roberto [1 ]
Toscani, Sergio [1 ]
Zanoni, Michele [1 ]
机构
[1] Politecn Milan, Dipartimento Elettron Informaz & Bioingn, I-20133 Milan, Italy
[2] Univ Liverpool, Dept Elect Engn & Elect, Liverpool L69 3GJ, Merseyside, England
关键词
Calibration; current measurement; frequency response; frequency-domain analysis; inductance; measurement techniques; mutual coupling; shunts; skin effect; IMPULSE;
D O I
10.1109/TIM.2017.2668498
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper the development of a new design solution for high-current shunt resistors is presented, which allows achieving very good accuracy while requiring a simple and low-cost manufacturing process. It is based on a solid cylinder having the voltage measurement circuit which runs through two holes drilled in the cylinder itself. Starting from the well-known expression of the current density in a cylindrical conductor, the frequency response of the shunt is obtained in closed form as a function of the geometric parameters. In turn, the positions of the voltage measurement terminals are chosen by optimizing the frequency response function over a specified range. A shunt prototype has been manufactured and its measurement performance has been evaluated. The experimental results confirm the validity of the approach and highlight the significant improvement with respect to the single-hole cylindrical shunt which has been recently proposed by the authors. The obtained measurement accuracy is noticeable when compared with the ease of manufacturing.
引用
收藏
页码:2266 / 2273
页数:8
相关论文
共 50 条
  • [21] A game-theoretic approach for calibration of low-cost magnetometers under noise uncertainty
    Siddharth, S.
    Ali, A. S.
    El-Sheimy, N.
    Goodall, C. L.
    Syed, Z. F.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (02)
  • [22] The calibration and deployment of a low-cost methane sensor
    Riddick, Stuart N.
    Mauzerall, Denise L.
    Celia, Michael
    Allen, Grant
    Pitt, Joseph
    Kang, Mary
    Riddick, John C.
    ATMOSPHERIC ENVIRONMENT, 2020, 230
  • [23] Laboratory assessment of low-cost PM monitors
    Manikonda, Abhisek
    Zikova, Nadezda
    Hopke, Philip K.
    Ferro, Andrea R.
    JOURNAL OF AEROSOL SCIENCE, 2016, 102 : 29 - 40
  • [24] A Low-Cost Optoacoustic Sensor for Environmental Monitoring
    Stylogiannis, Antonios
    Kousias, Nikolaos
    Kontses, Anastasios
    Ntziachristos, Leonidas
    Ntziachristos, Vasilis
    SENSORS, 2021, 21 (04) : 1 - 14
  • [25] GNSS Based Low-Cost Magnetometer Calibration
    Andel, Jan
    Simak, Vojtech
    Kanalikova, Alzbeta
    Pirnik, Rastislav
    SENSORS, 2022, 22 (21)
  • [26] Skin effect in a thin cylindrical metallic wire
    E. V. Zavitaev
    O. V. Rusakov
    A. A. Yushkanov
    Physics of the Solid State, 2012, 54 : 1109 - 1116
  • [27] Skin effect in a thin cylindrical metallic wire
    Zavitaev, E. V.
    Rusakov, O. V.
    Yushkanov, A. A.
    PHYSICS OF THE SOLID STATE, 2012, 54 (06) : 1109 - 1116
  • [28] A low-cost, flexible and portable volumetric capturing system
    Sterzentsenko, Vladimiros
    Karakottas, Antonis
    Papachristou, Alexandros
    Zioulis, Nikolaos
    Doumanoglou, Alexandros
    Zarpalas, Dimitrios
    Daras, Petros
    2018 14TH INTERNATIONAL CONFERENCE ON SIGNAL IMAGE TECHNOLOGY & INTERNET BASED SYSTEMS (SITIS), 2018, : 200 - 207
  • [29] Calibration verification of a low-cost method for MEMS accelerometers
    Parsi, B.
    Bahrami, M.
    Esfahani, A. Monemian
    Sany, B. Seyedzadeh
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2014, 36 (05) : 579 - 587
  • [30] The syringe potentiometer: a low-cost device for pneumotachograph calibration
    Cross, Troy J.
    Kelley, Eli F.
    Hardy, Tim A.
    Isautier, Jennifer M. J.
    Johnson, Bruce D.
    JOURNAL OF APPLIED PHYSIOLOGY, 2019, 127 (04) : 1150 - 1162