Remote Photoplethysmography Is an Accurate Method to Remotely Measure Respiratory Rate: A Hospital-Based Trial

被引:11
作者
Allado, Edem [1 ,2 ,3 ]
Poussel, Mathias [1 ,2 ]
Renno, Justine [3 ]
Moussu, Anthony [1 ,3 ]
Hily, Oriane [1 ]
Temperelli, Margaux [1 ]
Albuisson, Eliane [4 ,5 ,6 ]
Chenuel, Bruno [1 ,2 ]
机构
[1] Ctr Univ Med Sport & Act Phys Adaptees, Explorat Fonct Resp, CHRU Nancy, F-54000 Nancy, France
[2] Univ Lorraine, DevAH, F-54000 Nancy, France
[3] OMEOS, F-54000 Nancy, France
[4] CHRU Nancy, Direct Rech Clin & Innovat, F-54000 Nancy, France
[5] Univ Lorraine, IECL, CNRS, F-54000 Nancy, France
[6] Univ Lorraine, Dept Grand Est Rech Soins Primaires DEGERESP, F-54000 Nancy, France
关键词
respiratory rate; Remote photoplethysmography; vital signs; EARLY WARNING SCORE; HEART-RATE; EMERGENCY-DEPARTMENT; RELIABILITY; EXERCISE; VALIDITY;
D O I
10.3390/jcm11133647
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Remote photoplethysmography imaging (rPPG) is a new solution proposed to measure vital signs, such as respiratory rate (RR) in teleconsultation, by using a webcam. The results, presented here, aim at evaluating the accuracy of such remote measurement methods, compared with existing measurement methods, in a real-life clinical setting. For each patient, measurement of RR, using the standard system (control), has been carried out concomitantly with the experimental system. A 60-s time frame was used for the measurements made by our rPPG system. Age, gender, BMI, and skin phototype were collected. We performed the intraclass correlation coefficient and Bland-Altman plot to analyze the accuracy and precision of the rPPG algorithm readings. Measurements of RR, using the two methods, have been realized on 963 patients. Comparison of the two techniques showed excellent agreement (96.0%), with most of the patients (n = 924-standard patients) being in the confidence interval of 95% in Bland-Altman plotting. There were no significant differences between standard patients and outlier patients for demographic and clinical characteristics. This study indicates a good agreement between the rPPG system and the control, thus allowing clinical use of this remote assessment of the respiratory rate.
引用
收藏
页数:8
相关论文
共 37 条
[1]   Cardiopulmonary signal acquisition from different regions using video imaging analysis [J].
Al-Naji, Ali ;
Chahl, Javaan ;
Lee, Sang-Heon .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2019, 7 (02) :119-133
[2]   Innovative measurement of routine physiological variables (heart rate, respiratory rate and oxygen saturation) using a remote photoplethysmography imaging system: a prospective comparative trial protocol [J].
Allado, Edem ;
Poussel, Mathias ;
Moussu, Anthony ;
Saunier, Veronique ;
Bernard, Yohann ;
Albuisson, Eliane ;
Chenuel, Bruno .
BMJ OPEN, 2021, 11 (08)
[3]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[4]   Admission respiratory status predicts mortality in COVID-19 [J].
Chatterjee, Neal A. ;
Jensen, Paul N. ;
Harris, Andrew W. ;
Nguyen, Daniel D. ;
Huang, Henry D. ;
Cheng, Richard K. ;
Savla, Jainy J. ;
Larsen, Timothy R. ;
Gomez, Joanne Michelle D. ;
Du-Fay-de-Lavallaz, Jeanne M. ;
Lemaitre, Rozenn N. ;
McKnight, Barbara ;
Gharib, Sina A. ;
Sotoodehnia, Nona .
INFLUENZA AND OTHER RESPIRATORY VIRUSES, 2021, 15 (05) :569-572
[5]  
Chourpiliadis C., 2022, STATPEARLS
[6]   Accuracy of smartphone apps for heart rate measurement [J].
Coppetti, Thomas ;
Brauchlin, Andreas ;
Mueggler, Simon ;
Attinger-Toller, Adrian ;
Templin, Christian ;
Schoenrath, Felix ;
Hellermann, Jens ;
Luescher, Thomas F. ;
Biaggi, Patric ;
Wyss, Christophe A. .
EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2017, 24 (12) :1287-1293
[7]   Detection of atrial fibrillation using contactless facial video monitoring [J].
Couderc, Jean-Philippe ;
Kyal, Survi ;
Mestha, Lalit K. ;
Xu, Beilei ;
Peterson, Derick R. ;
Xia, Xiaojuan ;
Hall, Burr .
HEART RHYTHM, 2015, 12 (01) :195-201
[8]  
Cretikos MA, 2008, MED J AUSTRALIA, V188, P657
[9]   Current clinical methods of measurement of respiratory rate give imprecise values [J].
Drummond, Gordon B. ;
Fischer, Darius ;
Arvind, D. K. .
ERJ OPEN RESEARCH, 2020, 6 (03) :1-8
[10]   THE VALIDITY AND PRACTICALITY OF SUN-REACTIVE SKIN TYPE-I THROUGH TYPE-VI [J].
FITZPATRICK, TB .
ARCHIVES OF DERMATOLOGY, 1988, 124 (06) :869-871