A new potentiometric sensor for the determination of ketamine hydrochloride in ampoules and urine

被引:18
|
作者
Abu Shawish, Hazem M. [1 ]
Saadeh, Salman M. [2 ]
Tamos, Hassan [3 ]
Abed-Almonem, Khalid I. [4 ]
Al Khalili, Osama [5 ]
机构
[1] Al Aqsa Univ, Coll Sci, Dept Chem, Gaza, Israel
[2] Islamic Univ, Fac Sci, Dept Chem, Gaza, Israel
[3] Al Azhar Univ, Dept Chem, Gaza, Israel
[4] Minist Educ, Gaza, Israel
[5] Minist Hlth, Publ Hlth Lab, Gaza, Israel
关键词
ION-SELECTIVE ELECTRODES; FLOW-INJECTION ANALYSIS; CARBON-PASTE; GAS-CHROMATOGRAPHY; MEMBRANE; NORKETAMINE; PLASMA; DEHYDRONORKETAMINE; ENANTIOMERS; PERFORMANCE;
D O I
10.1039/c4ay01986e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ketamine drug in urine and pharmaceutical preparations was determined by a new chemically modified carbon paste electrode (CMCPE) based on an ion-exchanger of ketamine hydrochloride with sodium tetraphenylborate (KT-TPB) as a chemical modifier. The best performance was exhibited by the electrode having a paste containing 0.5 wt% ion-exchanger (KT-TPB), 54.3 wt% graphite, 45.0 wt% tris(2-ethylhexyl) phosphate (TEPh) and 0.2 wt% sodium tetraphenylborate (Na-TPB). The prepared electrode showed a Nernstian slope of 58.9 +/- 0.3 mV per decade for ketamine ions in the concentration range of 9.0 x 10(-6) M to 1.0 x 10(-2) M with a limit of detection of 7.3 x 10(-6) M. The electrode has a short and stable response time of 8 s and good reproducibility, and it can be used in a pH range of 3.7-6.6. The selective coefficients were determined in relation to several inorganic and organic ions, sugars and some common drug excipients. Ketamine is determined successfully in ampoule and urine using the standard addition and the calibration curve methods.
引用
收藏
页码:301 / 308
页数:8
相关论文
共 50 条
  • [1] Development of new potentiometric sensors for the determination of proguanil hydrochloride in serum and urine
    Fatehy M.Abdel-Haleem
    Mohamed Saad
    Mohamed S.Rizk
    ChineseChemicalLetters, 2016, 27 (06) : 857 - 863
  • [2] Development of new potentiometric sensors for the determination of proguanil hydrochloride in serum and urine
    Abdel-Haleem, Fatehy M.
    Saad, Mohamed
    Rizk, Mohamed S.
    CHINESE CHEMICAL LETTERS, 2016, 27 (06) : 857 - 863
  • [3] Potentiometric sensor for the high throughput determination of Tetramisole hydrochloride
    Gupta, Vinod Kumar
    Singh, Ashok Kumar
    Gupta, Barkha
    COMBINATORIAL CHEMISTRY & HIGH THROUGHPUT SCREENING, 2007, 10 (07) : 583 - 594
  • [4] Flow injection potentiometric sensor for determination of phenylpropanolamine hydrochloride
    Issa, Y. M.
    Khalil, M. M.
    Zayed, S. I. M.
    Hussein, Ahmed
    ARABIAN JOURNAL OF CHEMISTRY, 2009, 2 (01) : 41 - 46
  • [5] Quantitative Determination of Duloxetine Hydrochloride in Biological Samples of Blood Serum and Urine Using a Novel Potentiometric Sensor
    Pourhakkkaka, Parvin
    Karimi, Mohammad Ali
    Tavallali, Hossein
    Ardakani, Mohammad Mazloum
    Pourhakkak, Pouran
    Rahimi, Eisa
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (03): : 229 - 239
  • [6] Determination of haloperidol drug in ampoules and in urine samples using a potentiometric modified carbon paste electrode
    Abu Shawish, Hazem M.
    Almonem, Khaled I. Abed
    Saadeh, Salman M.
    Al-Iham, Wael S.
    MEASUREMENT, 2016, 78 : 180 - 186
  • [7] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    El-Attar, Rehab O.
    Hendawy, Hassan A. M.
    Khaled, Elmorsy
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2020, 17 (11) : 3019 - 3029
  • [8] A Novel Potentiometric Sensor for Determination of Tramadol Hydrochloride in Biological Samples
    Pourhakkak, Parvin
    Karimi, Mohammad Ali
    Pourhakkak, Pouran
    Ardakani, Mohammad Mazloum
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (02): : 191 - 200
  • [9] Potentiometric screen-printed sensor for determination of oxybutynin hydrochloride
    Rehab O. El-Attar
    Hassan A. M. Hendawy
    Elmorsy Khaled
    Journal of the Iranian Chemical Society, 2020, 17 : 3019 - 3029
  • [10] New Potentiometric Sensor for Determination of Metformin
    Zh. Kormosh
    N. Kormosh
    S. Golub
    Yu. Pachenko
    O. Yurchenko
    T. Savchuk
    S. Korolchuk
    S. Borkova
    S. Suprunovich
    Pharmaceutical Chemistry Journal, 2022, 56 : 1140 - 1143