Undetectable Concentrations of a Food and Drug Administration-approved High-sensitivity Cardiac Troponin T Assay to Rule Out Acute Myocardial Infarction at Emergency Department Arrival

被引:30
作者
McRae, Andrew D. [1 ,2 ]
Innes, Grant [1 ,2 ]
Graham, Michelle [5 ]
Lang, Eddy [1 ,2 ]
Andruchow, James E. [1 ]
Ji, Yunqi [3 ]
Vatanpour, Shabnam [1 ]
Abedin, Tasnima [3 ]
Yang, Hong [2 ]
Southern, Danielle A. [2 ]
Wang, Dongmei [3 ]
Seiden-Long, Isolde [4 ]
DeKoning, Lawrence [4 ]
Kavsak, Peter [6 ]
机构
[1] Univ Calgary, Dept Emergency Med, Calgary, AB, Canada
[2] Univ Calgary, Dept Community Hlth Sci, Calgary, AB, Canada
[3] Alberta Hlth Serv, Calgary, AB, Canada
[4] Calgary Lab Serv, Calgary, AB, Canada
[5] Univ Alberta, Dept Cardiol, Edmonton, AB, Canada
[6] McMaster Univ, Dept Pathol & Mol Med, Hamilton, ON, Canada
基金
加拿大健康研究院;
关键词
ACUTE CHEST-PAIN; DISCHARGE; RISK;
D O I
10.1111/acem.13229
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The objective of this study was to quantify the sensitivity of very low concentrations of high-sensitivity cardiac troponin T (hsTnT) at ED arrival for acute myocardial infarction (AMI) in a large cohort of chest pain patients evaluated in real-world clinical practice. Methods: This retrospective study included consecutive ED patients with suspected cardiac chest pain evaluated in four urban EDs, excluding those with ST-elevation AMI, cardiac arrest or abnormal kidney function. The primary outcomes were AMI at 7, 30, and 90 days. Secondary outcomes included major adverse cardiac events (MACE; all-cause mortality, AMI, and revascularization) and the individual MACE components. Test characteristics were calculated for hsTnT values from 3 to 200ng/L . Results: A total of 7,130 patients met inclusion criteria. AMI incidences at 7, 30, and 90 days were 5.8, 6.0, and 6.2%. When the hsTnT assay was performed at ED arrival, the limit of blank of the assay (3ng/L) ruled out 7-day AMI in 15.5% of patients with 100% sensitivity and negative predictive value (NPV). The limit of detection of the assay (5ng/L) ruled out AMI in 33.6% of patients with 99.8% sensitivity and 99.95% NPV for 7-day AMI. The limit of quantification (the Food and Drug Administration [FDA]-approved cutoff for lower the reportable limit) of 6ng/L ruled out AMI in 42.2% of patients with 99.8% sensitivity and 99.95% NPV. The sensitivities of the cutoffs of <3, <5, and <6ng/L for 7-day MACE were 99.6, 97.4, and 96.6%, respectively. The NPVs of the cutoffs of <3, <5, and <6ng/L for 7-day MACE were 99.8, 99.5, and 99.4%, respectively. A secondary analysis was performed in a subgroup of 3,549 higher-risk patients who underwent serial troponin testing. In this subgroup, a cutoff of 3ng/L ruled out 7-day AMI in 9.6% of patients with 100% sensitivity and NPV, a cutoff of 5ng/L ruled out 7-day AMI in 23.3% of patients with 99.7% sensitivity and 99.9% NPV, and a cutoff of 6ng/L ruled out 7-day AMI in 29.8% of patients with 99.7 and 99.9% NPV. In the higher-risk subgroup, the sensitivities of cutoffs of <3, <5, and <6ng/L for 7-day MACE were 99.8, 97.4, and 96.6%, respectively. In this higher-risk subgroup, the NPV of cutoffs of <3, <5, and <6ng/L for 7-day MACE were 99.7, 98.5, and 98.4%, respectively. Conclusions; When used in real-world clinical practice conditions, hsTnT concentrations<6ng/L (below the lower reportable limit for an FDA-approved assay) at the time of ED arrival can rule out AMI with very high sensitivity and NPV. The sensitivity for MACE is unacceptably low, and thus a single-troponin rule-out strategy should only be used in the context of a structured risk evaluation.
引用
收藏
页码:1267 / 1277
页数:11
相关论文
共 21 条
[2]  
[Anonymous], MYOC INF AC EARL RUL
[3]  
[Anonymous], CJEM
[4]  
[Anonymous], CRIT PATHW CARDIOL
[5]  
Bhuiya Farida A, 2010, NCHS Data Brief, P1
[6]   Identifying Patients Suitable for Discharge After a Single-Presentation High-Sensitivity Troponin Result: A Comparison of Five Established Risk Scores and Two High-Sensitivity Assays [J].
Carlton, Edward W. ;
Khattab, Ahmed ;
Greaves, Kim .
ANNALS OF EMERGENCY MEDICINE, 2015, 66 (06) :635-645
[7]   The impact of high-sensitivity troponin implementation on hospital operations and patient outcomes in 3 tertiary care centers [J].
Crowder, Kathryn R. ;
Jones, Tristan D. ;
Lang, Eddy S. ;
Wang, Dongmei M. ;
Clark, Steven M. ;
Innes, Grant D. ;
McMeekin, James D. ;
Graham, Michelle M. ;
McRae, Andrew D. .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (12) :1790-1794
[8]  
Ghali WA, 2000, CAN J CARDIOL, V16, P1225
[9]   The health care burden of acute chest pain [J].
Goodacre, S ;
Cross, E ;
Arnold, J ;
Angelini, K ;
Capewell, S ;
Nicholl, J .
HEART, 2005, 91 (02) :229-230
[10]  
Kavsak Peter A, 2015, Pract Lab Med, V1, P28, DOI 10.1016/j.plabm.2015.02.001