LECANDUS study (LEsion CANdidate Detection in UltraSound Data): evaluation of image analysis algorithms for breast lesion detection in volume ultrasound data

被引:4
作者
Golatta, Michael [1 ]
Zeegers, Desiree [1 ]
Filippatos, Konstantinos [2 ]
Binder, Leah-Larissa [1 ]
Scharf, Alexander [1 ]
Rauch, Geraldine [3 ]
Rom, Joachim [1 ]
Schuetz, Florian [1 ]
Sohn, Christof [1 ]
Heil, Joerg [1 ]
机构
[1] Univ Breast Unit, Neuenheimer Feld 440, D-69120 Heidelberg, Germany
[2] MeVis BreastCare Solut GmbH & Co KG, Univ Allee 29, D-28359 Bremen, Germany
[3] Heidelberg Univ, Inst Med Biometry & Informat, D-69120 Heidelberg, Germany
关键词
Ultrasound; Breast; 3D-scanning; CAD (Computer-aided diagnosis); Blob detector; ACCURACY; SCANNER; DIAGNOSIS; CANCER; MASSES;
D O I
10.1007/s00404-016-4127-5
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study aims at developing and evaluating a prototype of a lesion candidate detection algorithm for a 3D-US computer-aided diagnosis (CAD) system. Additionally, to routine imaging, automated breast volume scans (ABVS) were performed on 63 patients. All ABVS exams were analyzed and annotated before the evaluation with different algorithm blob detectors characterized by different blob-radiuses, voxel-sizes and the quantiles of blob filter responses to find lesion candidates. Lesions found in candidates were compared to the prior annotations. All histologically proven lesions were detected with at least one algorithm. The algorithm with optimal sensitivity detected all cancers (sensitivity = 100 %) with a very low positive predictive value due to a high false-positive rate. ABVS is a new technology which can be analyzed by a CAD software. Using different algorithms, lesions can be detected with a very high and accurate sensitivity. Further research for feature extraction and lesion classification is needed aiming at reducing the false-positive hits.
引用
收藏
页码:423 / 428
页数:6
相关论文
共 20 条
[1]   Evaluation of the Accuracy of a Computer-aided Diagnosis (CAD) System in Breast Ultrasound according to the Radiologist's Experience [J].
Chabi, Marie-Laure ;
Borget, Isabelle ;
Ardiles, Rosario ;
Aboud, Ghassen ;
Boussouar, Samia ;
Vilar, Vanessa ;
Dromain, Clarisse ;
Balleyguier, Corinne .
ACADEMIC RADIOLOGY, 2012, 19 (03) :311-319
[2]  
Frangi AF, 1998, LECT NOTES COMPUT SC, V1496, P130, DOI 10.1007/BFb0056195
[3]  
Friman O, 2011, GAUSSHESSIAN MLMODUL
[4]   Interobserver reliability of automated breast volume scanner (ABVS) interpretation and agreement of ABVS findings with hand held breast ultrasound (HHUS), mammography and pathology results [J].
Golatta, Michael ;
Franz, Dorothea ;
Harcos, Aba ;
Junkermann, Hans ;
Rauch, Geraldine ;
Scharf, Alexander ;
Schuetz, Florian ;
Sohn, Christof ;
Heil, Joerg .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) :E332-E336
[5]  
Hashimoto Beverly E, 2008, Ultrasound Q, V24, P31, DOI 10.1097/RUQ.0b013e31816b8cdf
[6]   Development of a fully automatic scheme for detection of masses in whole breast ultrasound images [J].
Ikedo, Yuji ;
Fukuoka, Daisuke ;
Hara, Takeshi ;
Fujita, Hiroshi ;
Takada, Etsuo ;
Endo, Tokiko ;
Morita, Takako .
MEDICAL PHYSICS, 2007, 34 (11) :4378-4388
[7]   Automated analysis of breast parenchymal patterns in whole breast ultrasound images: preliminary experience [J].
Ikedo, Yuji ;
Morita, Takako ;
Fukuoka, Daisuke ;
Hara, Takeshi ;
Lee, Gobert ;
Fujita, Hiroshi ;
Takada, Etsuo ;
Endo, Tokiko .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2009, 4 (03) :299-306
[8]   THE STRUCTURE OF IMAGES [J].
KOENDERINK, JJ .
BIOLOGICAL CYBERNETICS, 1984, 50 (05) :363-370
[9]   Selective enhancement filters for nodules, vessels, and airway walls in two- and three-dimensional CT scans [J].
Li, Q ;
Sone, S ;
Doi, K .
MEDICAL PHYSICS, 2003, 30 (08) :2040-2051
[10]   Analysis of eighty-one cases with breast lesions using automated breast volume scanner and comparison with handheld ultrasound [J].
Lin, Xi ;
Wang, Jianwei ;
Han, Feng ;
Fu, Jianhua ;
Li, Anhua .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) :873-878