Single-slice rebinning reconstruction in spiral cone-beam computed tomography

被引:0
作者
Bruder, H [1 ]
Kachelriess, M
Schaller, S
Stierstorfer, K
Flohr, T
机构
[1] Siemens Med Engn Grp, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
关键词
cone artifact; cone-beam CT; contrast resoltion; image noise; single-slice reconstruction; spatial resolution; spiral CT; spiral interpolation;
D O I
暂无
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
At the advent of multislice computed tomography (CT) a variety of approximate cone-beam algorithms have been proposed suited for reconstruction of small cone-angle CT data in a spiral mode of operation. The goal of this study is to identify a practical and efficient approximate cone-beam method, extend its potential for medical use, and demonstrate its performance at medium cone-angles required for area detector CT. We will investigate two different approximate single-slice rebinning algorithms for cone-beam CT: the multirow Fourier reconstruction (MFR) [1] and an extension of the advanced single-slice rebinning method (ASSR) [2], [3], which combines the idea of ASSR with a z-filtering approach. Thus, both algorithms, MFR and ASSR, are formulated in the framework of z-filtering using optimized spiral interpolation algorithms. In each view, X-ray samples to he used for reconstruction are identified, which describe an approximation to a virtual reconstruction plane. The performance of approximate reconstruction should improve as the virtual reconstruction plane better fits the spiral focus path. The image quality of the respective reconstruction will be assessed with respect to image artifacts, spatial resolution, contrast resolution, and image noise. It turns out that the ASSR method using tilted reconstruction planes is a practical and efficient algorithm, providing image quality comparable to that of a single-row scanning system even with a 46-row detector at a table feed of 64 mm, Both algorithms tolerate any table feed below the maximum value associated to the detector height. Due to the z-filter approach, all detector data sampled can be used for image reconstruction.
引用
收藏
页码:873 / 887
页数:15
相关论文
共 22 条
[1]  
BRUDER M, IN PRESS SPIE MED IA
[2]  
DANIELSSON PE, P 1997 INT M FULL 3D, P141
[3]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[4]  
HEUSCHER DJ, P 1999 INT M FULL 3, P204
[5]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[6]   Advanced single-slice rebinning in cone-beam spiral CT [J].
Kachelriess, M ;
Schaller, S ;
Kalender, WA .
MEDICAL PHYSICS, 2000, 27 (04) :754-772
[7]  
KACHELRIESS M, IN PRESS SPIE MED IM
[8]  
KACHELRIESS M, P 1999 INT M FULL 3D, P383
[9]  
KALENDER WA, 1995, MED CT ULTRASOUND CU
[10]  
KALENDER WA, IN PRESS COMPUTED TO