In-Situ X-Ray Diffraction Study of the Evolution of NiO Microstructure Under 120 MeV Au Ion Irradiation

被引:2
|
作者
Mallick, P. [1 ]
Dash, B. N. [2 ,4 ]
Kulriya, P. K. [3 ]
Agarwal, D. C. [3 ]
Avasthi, D. K. [3 ]
Kanjilal, D. [3 ]
Mishra, N. C. [4 ]
机构
[1] North Orissa Univ, Dept Phys, Baripada 757003, India
[2] Salipur Coll, Dept Phys, Salipur 754202, India
[3] Interuniv Accelerator Ctr, New Delhi 110067, India
[4] Utkal Univ, Dept Phys, Bhubaneswar 751004, Orissa, India
关键词
Ion Irradiation; Nanoparticles; Electronic Excitation; Thermal Spike Model; In-Situ XRD; NiO; SWIFT HEAVY-IONS; THIN-FILMS; TRACK FORMATION; SPIKE MECHANISM; LATENT TRACKS; GRAIN-GROWTH; SOLIDS;
D O I
10.1166/asl.2014.5371
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Modification of the microstructure of 300 nm thick NiO thin film deposited by pulsed laser deposition method under 120 MeV Au ion irradiation was studied by in-situ X-ray diffraction(XRD) at 300 K. Irradiation led to different effects on the crystallinity of the films at different ion fluences. In the low fluence regime, crystalline quality of the films improved with consequent increase in the XRD peak intensity and decrease of the full width at half maximum (FWHM) of the XRD peaks with increasing ion fluence up to 3 x 10(11) ions cm(-2). At higher ion fluences, the crystalline quality decreased. Thermal spike model with a transient temperature profile exceeding the melting temperature inside the track explains the second effect and a temperature radially decreasing away from the track region, but still high enough to anneal out the pre-existing defects in the region surrounding the ion tracks explains the first effect. Radius of the ion tracks (similar to 1.9 nm) calculated by fitting the fluence dependence of XRD peak intensity agrees with the value (2 nm) predicted by the inelastic thermal spike model. Low density of the disordered material in the track region created due to the electronic energy loss of the energetic ions exceeding the threshold value for track formation was found to produce radial compressive strain on the crystalline matrix around the ion tracks leading to shifting of XRD peaks towards higher angles with increasing ion fluence. Fitting the variation of the strain with ion fluence to Poisson relation yielded radius of the strained region as 6.9 nm. Our study thus suggests three modes of materials modification under the attendant ion beam: (i) annealing of defects in regions surrounding the ion tracks, (ii) creation of columnar defects along the ion path and (iii) a strained matrix around each ion track.
引用
收藏
页码:607 / 611
页数:5
相关论文
共 50 条
  • [41] Microstructure evolution during cold rolling in a nanocrystalline Ni-Fe alloy determined by synchrotron X-ray diffraction
    Li, L.
    Ungar, T.
    Wang, Y. D.
    Morris, J. R.
    Tichy, G.
    Lendvai, J.
    Yang, Y. L.
    Ren, Y.
    Choo, H.
    Liaw, P. K.
    ACTA MATERIALIA, 2009, 57 (17) : 4988 - 5000
  • [42] Using In-Situ Laboratory and Synchrotron-Based X-ray Diffraction for Lithium-Ion Batteries Characterization: A Review on Recent Developments
    Llewellyn, Alice V.
    Matruglio, Alessia
    Brett, Dan J. L.
    Jervis, Rhodri
    Shearing, Paul R.
    CONDENSED MATTER, 2020, 5 (04): : 1 - 28
  • [43] Origin of swift heavy ion induced stress in textured ZnO thin films: An in situ X-ray diffraction study
    Singh, Fouran
    Kulriya, P. K.
    Pivin, J. C.
    SOLID STATE COMMUNICATIONS, 2010, 150 (37-38) : 1751 - 1754
  • [44] In-situ X-ray diffraction analysis of hydrogen-induced LaMg12 phase decomposition
    Jiang, JJ
    Sun, DL
    ACTA METALLURGICA SINICA, 2002, 38 (03) : 288 - 290
  • [45] DEVICE DEGRADATION STUDIES OF CIGS SOLAR CELLS USING IN-SITU HIGH TEMPERATURE X-RAY DIFFRACTION
    Krishnan, R.
    Tong, G.
    Kaczynski, R.
    Schoop, U.
    Payzant, E. A.
    Anderson, T. J.
    Kim, W. K.
    2012 38TH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2012, : 1970 - 1973
  • [46] In-Situ X-Ray Diffraction Measurement During Deformation of Austenite Above the Ae3 Temperature
    Aranas, Clodualdo, Jr.
    Rodrigues, Samuel
    Siciliano, Fulvio
    Jonas, John J.
    TMS 2020 149TH ANNUAL MEETING & EXHIBITION SUPPLEMENTAL PROCEEDINGS, 2020, : 1789 - 1798
  • [47] Chemical and Structural In-Situ Characterization of Model Electrocatalysts by Combined Infrared Spectroscopy and Surface X-ray Diffraction
    Brummel, Olaf
    Jacobse, Leon
    Simanenko, Alexander
    Deng, Xin
    Geile, Simon
    Gutowski, Olof
    Vonk, Vedran
    Lykhach, Yaroslava
    Stierle, Andreas
    Libuda, Jorg
    JOURNAL OF PHYSICAL CHEMISTRY LETTERS, 2023, 14 (39) : 8820 - 8827
  • [48] In-situ X-ray micro-diffraction study of the metal-insulator phase transition in VO2 particles
    Faiyaz, Mohd
    Ha, Sung Soo
    Oh, Hojun
    Choi, Sukjune
    Noh, Do Young
    Kang, Hyon Chol
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 79 (03) : 315 - 320
  • [49] Reactor for nano-focused x-ray diffraction and imaging under catalytic in situ conditions
    Richard, M. -I.
    Fernandez, S.
    Hofmann, J. P.
    Gao, L.
    Chahine, G. A.
    Leake, S. J.
    Djazouli, H.
    De Bortoli, Y.
    Petit, L.
    Boesecke, P.
    Labat, S.
    Hensen, E. J. M.
    Thomas, O.
    Schulli, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (09)
  • [50] In Situ X-ray Diffraction as a Basic Tool to Study Oxide and Metal Oxide Catalysts
    Bulavchenko, Olga A.
    Vinokurov, Zakhar S.
    CATALYSTS, 2023, 13 (11)