Closing the Wearable Gap-Part V: Development of a Pressure-Sensitive Sock Utilizing Soft Sensors

被引:18
作者
Luczak, Tony [1 ]
Burch, Reuben F. [1 ]
Smith, Brian K. [1 ]
Carruth, Daniel W. [2 ]
Lamberth, John [3 ]
Chander, Harish [3 ]
Knight, Adam [3 ]
Ball, J. E. [4 ]
Prabhu, R. K. [5 ]
机构
[1] Mississippi State Univ, Dept Ind & Syst Engn, Mississippi State, MS 39762 USA
[2] Mississippi State Univ, Ctr Adv Vehicular Syst, Mississippi State, MS 39762 USA
[3] Mississippi State Univ, Dept Kinesiol, Mississippi State, MS 39762 USA
[4] Mississippi State Univ, Dept Elect & Comp Engn, Mississippi State, MS 39762 USA
[5] Mississippi State Univ, Dept Agr & Biol Engn, Mississippi State, MS 39762 USA
基金
美国国家科学基金会;
关键词
wearables; pressure; soft robotic sensors; ground reaction force; root mean square error; INSOLES; FORCE;
D O I
10.3390/s20010208
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The purpose of this study was to evaluate the use of compressible soft robotic sensors (C-SRS) in determining plantar pressure to infer vertical and shear forces in wearable technology: A ground reaction pressure sock (GRPS). To assess pressure relationships between C-SRS, pressure cells on a BodiTrak (TM) Vector Plate, and Kistler (TM) Force Plates, thirteen volunteers performed three repetitions of three different movements: squats, shifting center-of-pressure right to left foot, and shifting toes to heels with C-SRS in both anterior-posterior (A/P) and medial-lateral (M/L) sensor orientations. Pearson correlation coefficient of C-SRS to BodiTrak (TM) Vector Plate resulted in an average R-value greater than 0.70 in 618/780 (79%) of sensor to cell comparisons. An average R-value greater than 0.90 was seen in C-SRS comparison to Kistler (TM) Force Plates during shifting right to left. An autoregressive integrated moving average (ARIMA) was conducted to identify and estimate future C-SRS data. No significant differences were seen in sensor orientation. Sensors in the A/P orientation reported a mean R-2 value of 0.952 and 0.945 in the M/L sensor orientation, reducing the effectiveness to infer shear forces. Given the high R values, the use of C-SRSs to infer normal pressures appears to make the development of the GRPS feasible.
引用
收藏
页数:15
相关论文
共 33 条
[1]   Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review [J].
Amjadi, Morteza ;
Kyung, Ki-Uk ;
Park, Inkyu ;
Sitti, Metin .
ADVANCED FUNCTIONAL MATERIALS, 2016, 26 (11) :1678-1698
[2]  
[Anonymous], 2009, BIOMECHANICS MOTOR C
[3]   Batch Fabrication of Customizable Silicone-Textile Composite Capacitive Strain Sensors for Human Motion Tracking [J].
Atalay, Asli ;
Sanchez, Vanessa ;
Atalay, Ozgur ;
Vogt, Daniel M. ;
Haufe, Florian ;
Wood, Robert J. ;
Walsh, Conor J. .
ADVANCED MATERIALS TECHNOLOGIES, 2017, 2 (09)
[4]  
Beckham G., 2014, NEW STUDIES ATHLETIC, V29, P25
[5]  
Bunton Edwin E., 1993, Journal of Athletic Training, V28, P10
[6]   Super-stretchable, Transparent Carbon Nanotube-Based Capacitive Strain Sensors for Human Motion Detection [J].
Cai, Le ;
Song, Li ;
Luan, Pingshan ;
Zhang, Qiang ;
Zhang, Nan ;
Gao, Qingqing ;
Zhao, Duan ;
Zhang, Xiao ;
Tu, Min ;
Yang, Feng ;
Zhou, Wenbin ;
Fan, Qingxia ;
Luo, Jun ;
Zhou, Weiya ;
Ajayan, Pulickel M. ;
Xie, Sishen .
SCIENTIFIC REPORTS, 2013, 3
[7]   Closing the Wearable Gap-Part III: Use of Stretch Sensors in Detecting Ankle Joint Kinematics During Unexpected and Expected Slip and Trip Perturbations [J].
Chander, Harish ;
Stewart, Ethan ;
Saucier, David ;
Phuoc Nguyen ;
Luczak, Tony ;
Ball, John E. ;
Knight, Adam C. ;
Smith, Brian K. ;
Burch, Reuben F. ;
Prabhu, R. K. .
ELECTRONICS, 2019, 8 (10)
[8]   Comparison of an in-shoe pressure measurement device to a force plate: concurrent validity of center of pressure measurements [J].
Chesnin, KJ ;
Selby-Silverstein, L ;
Besser, MP .
GAIT & POSTURE, 2000, 12 (02) :128-133
[9]   RECURRENT NEURAL NETWORKS AND ROBUST TIME-SERIES PREDICTION [J].
CONNOR, JT ;
MARTIN, RD ;
ATLAS, LE .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1994, 5 (02) :240-254
[10]   Time-Series Analysis of Continuously Monitored Blood Glucose: The Impacts of Geographic and Daily Lifestyle Factors [J].
Doherty, Sean T. ;
Greaves, Stephen P. .
JOURNAL OF DIABETES RESEARCH, 2015, 2015