Objective: The value of sperm morphology as a predictor of a man's fertilizing potential has often been challenged because of different classification systems used to distinguish between normal and abnormal spermatozoa. The study aimed to monitor the reading skills of 53 laboratory technologists who are enrolled in a continuous quality control program for sperm morphology assessment. Design: Prospective analytical study. Setting: Academic hospital and academic institution setting. Patient(s): Sperm samples from the sperm donor program and andrology technicians from sub-Saharan Africa. Intervention(s): Papanicolaou-stained sperm slides were prepared and shipped on a quarterly basis to participating laboratories. Papanicolaou-prestained sperm morphology slides were used as test material for 21 months. Main Outcome Measure(s): Percentage normal spermatozoa. Result(s): A new statistical model was developed to record reading skills of the participating technicians. Reading skills were classified as marginal (5.7% of cases), good (11.3% of cases), and excellent (83% of cases). Participants maintained their morphological reading skills and agreed with the reference laboratory by not exceeding a SD limit of 0.2 to set stringent standards for the program. Conclusion(s): Technician proficiency can be monitored using the results of a quality control program. A continuous quality control program can be initiated only after intensive training, because baseline values at the onset of the quality control program serves as an internal reference value.
引用
收藏
页码:1637 / 1643
页数:7
相关论文
共 50 条
  • [21] A QUALITY-CONTROL SYSTEM FOR THE OPTIMIZED SPERM PENETRATION ASSAY
    JOHNSON, A
    BASSHAM, B
    LIPSHULTZ, LI
    LAMB, DJ
    FERTILITY AND STERILITY, 1995, 64 (04) : 832 - 837
  • [22] A harmonized quality control program for digital mammography
    Yaffe, Martin
    Mawdsley, Gordon
    Bloomquist, Aili
    DIGITAL MAMOGRAPHY, PROCEEDINGS, 2006, 4046 : 585 - 592
  • [23] Post swim-up versus original sperm quality, and strict criteria morphology, it's influence on fertilization rate in in vitro fertilization program: a pilot study
    Michaeli, M
    Peer, S
    Anderman, S
    Ballas, S
    Ellenbogen, A
    RESEARCH PAPERS IN FERTILITY AND REPRODUCTIVE MEDICINE, 2004, 1271 : 181 - 184
  • [24] Applying quality control to traffic condition monitoring
    Turochy, RE
    Smith, BL
    2000 IEEE INTELLIGENT TRANSPORTATION SYSTEMS PROCEEDINGS, 2000, : 15 - 20
  • [25] Quality Control of Monitoring Glycemia in Patients with Diabetes
    Solnica, Bogdan
    Naskalski, Jerzy W.
    Hebda-Szydlo, Alicja
    Sieradzki, Jacek
    POINT OF CARE, 2005, 4 (01): : 45 - 48
  • [26] An Analysis of Multirules for Monitoring Assay Quality Control
    Walker, Brandon S.
    Pearson, Lauren N.
    Schmidt, Robert L.
    LABORATORY MEDICINE, 2020, 51 (01) : 94 - 98
  • [27] Quality control in aerobiology: comparison different slide reading methods
    T. R. Cotos-Yáñez
    F. J. Rodríguez-Rajo
    A. Pérez-González
    M. J. Aira
    V. Jato
    Aerobiologia, 2013, 29 : 1 - 11
  • [28] Quality control in aerobiology: comparison different slide reading methods
    Cotos-Yanez, T. R.
    Rodriguez-Rajo, F. J.
    Perez-Gonzalez, A.
    Aira, M. J.
    Jato, V.
    AEROBIOLOGIA, 2013, 29 (01) : 1 - 11
  • [29] Human sperm morphology assessment since 2010: experience of an Australian external quality assurance programme
    Matson, Phillip
    Kitson, Michelle
    Zuvela, Emily
    REPRODUCTIVE BIOMEDICINE ONLINE, 2022, 44 (02) : 340 - 348
  • [30] Establishing a quality control program for an automated dosimetry system
    Li, SL
    O'Dea, TJ
    Geise, RA
    MEDICAL PHYSICS, 1999, 26 (08) : 1732 - 1737