Magnetoacoustic tomography with magnetic induction (MAT-MI)

被引:185
作者
Xu, Y [1 ]
He, B [1 ]
机构
[1] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN 55455 USA
关键词
D O I
10.1088/0031-9155/50/21/015
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report our theoretical and experimental investigations on a new imaging modality, magnetoacoustic tomography with magnetic induction (MAT-MI). In MAT-MI, the sample is located in a static magnetic field and a time-varying (mu s) magnetic field. The time-varying magnetic field induces an eddy current in the sample. Consequently, the sample will emit ultrasonic waves by the Lorentz force. The ultrasonic signals are collected around the object to reconstruct images related to the electrical impedance distribution in the sample. MAT-MI combines the good contrast of electrical impedance tomography with the good spatial resolution of sonography. MAT-MI has two unique features due to the solenoid nature of the induced electrical field. Firstly, MAT-MI could provide an explicit or simple quantitative reconstruction algorithm for the electrical impedance distribution. Secondly, it promises to eliminate the shielding effects of other imaging modalities in which the current is applied directly with electrodes. In the theoretical part, we provide formulae for both the forward and inverse problems of MAT-MI and estimate the signal amplitude in biological tissues. In the experimental part, the experimental setup and methods are introduced and the signals and the image of a metal object by means of MAT-MI are presented. The promising pilot experimental results suggest the feasibility of the proposed MAT-MI approach.
引用
收藏
页码:5175 / 5187
页数:13
相关论文
共 32 条
[1]  
ALZEIBAK S, 1995, P 9 INT C EL BIOIMP, P426
[2]  
BARKER AT, 1990, J PHYSIOL-LONDON, V423, P66
[3]   Magnetic stimulation coil and circuit design [J].
Davey, K ;
Epstein, CM .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (11) :1493-1499
[4]   Estimation of electrical conductivity distribution within the human head from magnetic flux density measurement [J].
Gao, N ;
Zhu, SA ;
He, B .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (11) :2675-2687
[5]  
GRIFFITHS H, 1998, P 10 INT C EL BIOIMP, P361
[6]  
He B, 2005, BIOELECTRIC ENG, P221
[7]  
He B., 2004, MODELING IMAGING BIO
[8]   STIMULATION OF CARDIAC MUSCLE BY A TIME-VARYING MAGNETIC FIELD [J].
IRWIN, DD ;
RUSH, S ;
EVERING, R ;
LEPESCHK.E ;
MONTGOME.DB ;
WEGGEL, RJ .
IEEE TRANSACTIONS ON MAGNETICS, 1970, MAG6 (02) :321-&
[9]   BIOELECTRIC CURRENT IMAGE-RECONSTRUCTION FROM MAGNETOACOUSTIC MEASUREMENTS [J].
ISLAM, MR ;
TOWE, BC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1988, 7 (04) :386-391
[10]  
Krestel E., 1990, IMAGING SYSTEMS MED