Biomechanical Comparison of Four Different Atlantoaxial Posterior Fixation Constructs in Adults A Finite Element Study

被引:42
作者
Chun, Dong Hyun [1 ]
Yoon, Do Heum [1 ]
Kim, Keung Nyun [1 ]
Yi, Seong [1 ]
Shin, Dong Ah [1 ]
Ha, Yoon [1 ]
机构
[1] Yonsei Univ, Coll Med, Dept Neurosurg, Seoul, South Korea
关键词
biomechanics; cervical spine; finite element model; posterior fixation; spine stabilization; TRANSARTICULAR SCREW FIXATION; LATERAL MASS SCREWS; C1; PEDICLE; AGE;
D O I
10.1097/BRS.0000000000002584
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Finite element analysis. Objective. To compare the biomechanical stability imparted to the C1 and C2 vertebrae by the transarticular (TA), C1 lateral mass (LM)-C2 pedicle (PS), C1LM-C2 pars, and C1LM-C2 translaminar (TL) screw fixation techniques. Summary of Background Data. Cadaveric biomechanical studies of several atlantoaxial posterior fixation techniques have been performed, showing significant heterogeneity in biomechanical properties among the studies. Methods. From computed tomography images, a nonlinear intact three-dimensional C1-2 finite element model was developed and validated. Four finite element models were reconstructed from different C1-2 fixation techniques. The range of motion (ROM) and maximum von Misses stresses for the four screw techniques were compared under flexion, extension, lateral bending, and axial rotation. Results. C1LM-C2PS showed the greatest decrease in ROM with flexion/extension and lateral bending. C1-2TA and C1LM-C2 pars showed less ROM reduction than the other techniques, in flexion/extension. C1LM-C2TL showed the least decrease in ROM during axial rotation. For C1-2TA, the maximum stress was in the C1-2 joint region. In the C1LM-C2PS, the C1 rod head, C2 pars screw, and C2TL screw were stressed at the C2 rod head. The maximal von Mises stress on the C1-2TA at the C1-2 joint site was the highest at flexion/extension, whereas the C1LM-C2PS had the lowest stress on the screw at flexion/extension and lateral bending. The C1LM-C2TL showed the highest stress in axial rotation and lateral bending. Conclusion. In this study, C1LM-C2PS fixation was the most stable technique. If surgeons have to use other fixation methods besides the C2 pedicle screw, they need to be aware that additional fixation or postoperative immobilization may be required to achieve ROM restriction. Careful observation at the maximum stress site on the screw including screw loosening, screw-bone interface disruption or screw fracture will be necessary during follow-up imaging examinations (x-ray and computed tomography scan) after atlantoaxial fixation.
引用
收藏
页码:E891 / E897
页数:7
相关论文
共 29 条
[1]   Biomechanics of occipitocervical fixation [J].
Anderson, PA ;
Oza, AL ;
Puschak, TJ ;
Sasso, R .
SPINE, 2006, 31 (07) :755-761
[2]   A Biomechanical Study to Evaluate the Effect of PMMA Augmentation and Restoration of the Strength of Cervical Vertebral Screws Inserted in an Osteoporotic Vertebral Body [J].
Chen, Chun ;
Zhao, Weidong ;
Liu, Dongxu ;
Sun, Peidong ;
Wu, Changfu ;
Ouyang, Jun .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (04) :224-231
[3]   Seven Years of Experience With C2 Translaminar Screw Fixation: Clinical Series and Review of the Literature [J].
Dorward, Ian G. ;
Wright, Neill M. .
NEUROSURGERY, 2011, 68 (06) :1491-1499
[4]   Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis [J].
Du, Jerry Y. ;
Aichmair, Alexander ;
Kueper, Janina ;
Wright, Timothy ;
Lebl, Darren R. .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) :151-161
[5]   Finite element analysis of posterior cervical fixation [J].
Duan, Y. ;
Wang, H. H. ;
Jin, A. M. ;
Zhang, L. ;
Min, S. X. ;
Liu, C. L. ;
Qiu, S. J. ;
Shu, X. Q. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (01) :23-29
[6]   Atlantoaxial Transarticular Screw Fixation: Update on Technique and Outcomes in 269 Patients [J].
Finn, Michael A. ;
Apfelbaum, Ronald I. .
NEUROSURGERY, 2010, 66 (03) :A184-A192
[7]   Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients [J].
Gluf, WM ;
Schmidt, MH ;
Apfelbaum, RI .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) :155-163
[8]   Pediatric and Adult Three-Dimensional Cervical Spine Kinematics Effect of Age and Sex Through Overall Motion [J].
Greaves, Laura L. ;
Van Toen, Carolyn ;
Melnyk, Angela ;
Koenig, Lynn ;
Zhu, Qingan ;
Tredwell, Stephen ;
Mulpuri, Kishore ;
Cripton, Peter A. .
SPINE, 2009, 34 (16) :1650-1657
[9]   BIOMECHANICAL EVALUATION OF 4 DIFFERENT POSTERIOR ATLANTOAXIAL FIXATION TECHNIQUES [J].
GROB, D ;
CRISCO, JJ ;
PANJABI, MM ;
WANG, P ;
DVORAK, J .
SPINE, 1992, 17 (05) :480-490
[10]   Cervical Spine Instrumentation in Children [J].
Hedequist, Daniel J. ;
Emans, John B. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2016, 24 (06) :370-378