Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging

被引:7
作者
Stemkens, Bjorn [1 ]
Benkert, Thomas [2 ,3 ]
Chandarana, Hersh [2 ,3 ]
Bittman, Mark E. [2 ,3 ]
Van den Berg, Cornelis A. T. [1 ]
Lagendijk, Jan J. W. [1 ]
Sodickson, Daniel K. [2 ,3 ]
Tijssen, Rob H. N. [1 ]
Block, Kai Tobias [2 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[2] NYU, Sch Med, Dept Radiol, Ctr Adv Imaging Innovat & Res CAI2R, New York, NY USA
[3] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York, NY USA
关键词
abdominal imaging; bulk motion; motion correction; prospective motion detection; real-time motion detection; RESPIRATORY MOTION; MRI; ARTIFACTS; RECONSTRUCTION; COMPENSATION; VARIANCE; SEDATION; BRAIN; RATIO;
D O I
10.1002/nbm.3830
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-Cartesian magnetic resonance imaging (MRI) sequences have shown great promise for abdominal examination during free breathing, but break down in the presence of bulk patient motion (i.e. voluntary or involuntary patient movement resulting in translation, rotation or elastic deformations of the body). This work describes a data-consistency-driven image stabilization technique that detects and excludes bulk movements during data acquisition. Bulk motion is identified from changes in the signal intensity distribution across different elements of a multi-channel receive coil array. A short free induction decay signal is acquired after excitation and used as a measure to determine alterations in the load distribution. The technique has been implemented on a clinical MR scanner and evaluated in the abdomen. Six volunteers were scanned and two radiologists scored the reconstructions. To show the applicability to other body areas, additional neck and knee images were acquired. Data corrupted by bulk motion were successfully detected and excluded from image reconstruction. An overall increase in image sharpness and reduction of streaking and shine-through artifacts were seen in the volunteer study, as well as in the neck and knee scans. The proposed technique enables automatic real-time detection and exclusion of bulk motion during MR examinations without user interaction. It may help to improve the reliability of pediatric MRI examinations without the use of sedation.
引用
收藏
页数:11
相关论文
共 35 条
[31]   An optimal radial profile order based on the golden ratio for time-resolved MRI [J].
Winkelmann, Stefanie ;
Schaeffter, Tobias ;
Koehler, Thomas ;
Eggers, Holger ;
Doessel, Olaf .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (01) :68-76
[32]   MR IMAGE ARTIFACTS FROM PERIODIC MOTION [J].
WOOD, ML ;
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :143-151
[33]   SUPPRESSION OF RESPIRATORY MOTION ARTIFACTS IN MAGNETIC-RESONANCE-IMAGING [J].
WOOD, ML ;
HENKELMAN, RM .
MEDICAL PHYSICS, 1986, 13 (06) :794-805
[34]   Motion Artifacts in MRI: A Complex Problem With Many Partial Solutions [J].
Zaitsev, Maxim ;
Maclaren, Julian ;
Herbst, Michael .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) :887-901
[35]   Fast Pediatric 3D Free-Breathing Abdominal Dynamic Contrast Enhanced MRI With High Spatiotemporal Resolution [J].
Zhang, Tao ;
Cheng, Joseph Y. ;
Potnick, Aaron G. ;
Barth, Richard A. ;
Alley, Marcus T. ;
Uecker, Martin ;
Lustig, Michael ;
Pauly, John M. ;
Vasanawala, Shreyas S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (02) :460-473