Adaptive bulk motion exclusion for improved robustness of abdominal magnetic resonance imaging

被引:7
作者
Stemkens, Bjorn [1 ]
Benkert, Thomas [2 ,3 ]
Chandarana, Hersh [2 ,3 ]
Bittman, Mark E. [2 ,3 ]
Van den Berg, Cornelis A. T. [1 ]
Lagendijk, Jan J. W. [1 ]
Sodickson, Daniel K. [2 ,3 ]
Tijssen, Rob H. N. [1 ]
Block, Kai Tobias [2 ,3 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiotherapy, Utrecht, Netherlands
[2] NYU, Sch Med, Dept Radiol, Ctr Adv Imaging Innovat & Res CAI2R, New York, NY USA
[3] NYU, Sch Med, Bernard & Irene Schwartz Ctr Biomed Imaging, Dept Radiol, New York, NY USA
关键词
abdominal imaging; bulk motion; motion correction; prospective motion detection; real-time motion detection; RESPIRATORY MOTION; MRI; ARTIFACTS; RECONSTRUCTION; COMPENSATION; VARIANCE; SEDATION; BRAIN; RATIO;
D O I
10.1002/nbm.3830
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Non-Cartesian magnetic resonance imaging (MRI) sequences have shown great promise for abdominal examination during free breathing, but break down in the presence of bulk patient motion (i.e. voluntary or involuntary patient movement resulting in translation, rotation or elastic deformations of the body). This work describes a data-consistency-driven image stabilization technique that detects and excludes bulk movements during data acquisition. Bulk motion is identified from changes in the signal intensity distribution across different elements of a multi-channel receive coil array. A short free induction decay signal is acquired after excitation and used as a measure to determine alterations in the load distribution. The technique has been implemented on a clinical MR scanner and evaluated in the abdomen. Six volunteers were scanned and two radiologists scored the reconstructions. To show the applicability to other body areas, additional neck and knee images were acquired. Data corrupted by bulk motion were successfully detected and excluded from image reconstruction. An overall increase in image sharpness and reduction of streaking and shine-through artifacts were seen in the volunteer study, as well as in the neck and knee scans. The proposed technique enables automatic real-time detection and exclusion of bulk motion during MR examinations without user interaction. It may help to improve the reliability of pediatric MRI examinations without the use of sedation.
引用
收藏
页数:11
相关论文
共 35 条
[1]   Adaptive retrospective correction of motion artifacts in cranial MRI with multicoil three-dimensional radial acquisitions [J].
Anderson, Ashley G., III ;
Velikina, Julia ;
Block, Walter ;
Wieben, Oliver ;
Samsonov, Alexey .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (04) :1094-1103
[2]   Thermal noise variance of a receive radiofrequency coil as a respiratory motion sensor [J].
Andreychenko, A. ;
Raaijmakers, A. J. E. ;
Sbrizzi, A. ;
Crijns, S. P. M. ;
Lagendijk, J. J. W. ;
Luijten, P. R. ;
van den Berg, C. A. T. .
MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) :221-228
[3]   Rapid gridding reconstruction with a minimal oversampling ratio [J].
Beatty, PJ ;
Nishimura, DG ;
Pauly, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (06) :799-808
[4]   Free-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging [J].
Benkert, Thomas ;
Feng, Li ;
Sodickson, Daniel K. ;
Chandarana, Hersh ;
Block, Kai Tobias .
MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (02) :565-576
[5]  
block kai tobias, 2014, Investigative Magnetic Resonance Imaging, V18, P87
[6]   Generalized self-navigated motion detection technique: Preliminary investigation in abdominal imaging [J].
Brau, ACS ;
Brittain, JH .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (02) :263-270
[7]   Prospective self-gating for simultaneous compensation of cardiac and respiratory motion [J].
Buehrer, Martin ;
Curcic, Jelena ;
Boesiger, Peter ;
Kozerke, Sebastian .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :683-690
[8]   Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling [J].
Chandarana, Hersh ;
Feng, Li ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Babb, James S. ;
Sodickson, Daniel K. ;
Otazo, Ricardo .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :10-16
[9]   Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient Echo Sequence A Viable Alternative for Contrast-Enhanced Liver Imaging in Patients Unable to Suspend Respiration [J].
Chandarana, Hersh ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Kim, Danny ;
Mossa, David J. ;
Babb, James S. ;
Kiefer, Berthold ;
Lee, Vivian S. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (10) :648-653
[10]   Free-breathing pediatric MRI with nonrigid motion correction and acceleration [J].
Cheng, Joseph Y. ;
Zhang, Tao ;
Ruangwattanapaisarn, Nichanan ;
Alley, Marcus T. ;
Uecker, Martin ;
Pauly, John M. ;
Lustig, Michael ;
Vasanawala, Shreyas S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :407-420