Fully automated multianalyte determination of different classes of pesticides, at picogram per litre levels in water, by on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry

被引:63
作者
Kampioti, AA
da Cunha, ACB
de Alda, ML
Barceló, D
机构
[1] CSIC, Dept Environm Chem, IIQAB, ES-08034 Barcelona, Spain
[2] La Salle Univ Ctr, Canoas, RS, Brazil
[3] Univ Patras, Dept Chem Engn, Lab Biochem Engn & Environm Technol, Patras 26500, Greece
关键词
pesticides; water; analysis; on-line solid-phase extraction; tandem mass spectrometry; automation;
D O I
10.1007/s00216-005-3332-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper reports the development of a fully automated method for the multianalyte determination of twenty pesticides belonging to different classes (triazines, phenylureas, organophosphates, anilines, acidic, propanil, and molinate) in natural and treated waters. The method, based on on-line solid-phase extraction-liquid chromatography-electrospray-tandem mass spectrometry, is highly sensitive (limits of detection between 0.004 and 2.8 ng L-1), precise (relative standard deviations between 2.0 and 12.1%), reliable (two selected reaction-monitoring transitions are monitored per compound), rapid (45 min per sample), and simple. The application of this method to the monitoring of the target compounds in a waterworks revealed the presence of the pesticides investigated at concentrations up to 516 and 82 ng L-1 (total pesticide concentration) in river water and ground water, respectively, used as sources, and their gradual removal through the purification process.
引用
收藏
页码:1815 / 1825
页数:11
相关论文
共 30 条