Intelligent Analysis of Samples by Semiquantitative Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) Technique: A Review

被引:17
作者
Krzciuk, Karina [1 ]
机构
[1] Jan Kochanowski Univ, Inst Chem, Geochem & Environm Div, 15G Swietokrzyska St, PL-25406 Kielce, Poland
关键词
ICP-MS; screening; semiquantitative analysis; trace elements; RARE-EARTH-ELEMENTS; TRACE-ELEMENTS; MULTIELEMENTAL ANALYSIS; PANORAMIC ANALYSIS; NATURAL-WATERS; WINE; QUALITY; MODE;
D O I
10.1080/10408347.2015.1053106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Inductively coupled plasma-mass spectrometry (ICP-MS) is a popular and routine analytical method that has been used for determination of trace elements since the 1980s. It provides fast quantitative analysis and allows the determination of more than 70 elements with good accuracy and very low detection limits, but requires an intricate calibration procedure. In analyses of samples for which very low detection limits are not required a semiquantitative ICP-MS analysis mode can be used. This approach is more time- and cost-effective, and it uses a simple calibration procedure. This article presents a critical review of the semiquantitative (SQ) mode of ICP-MS and describes current and future applications of SQ analysis.
引用
收藏
页码:284 / 290
页数:7
相关论文
共 50 条
[1]   Advantages and limitations of the semi-quantitative operation mode of an inductively coupled plasma-mass spectrometer for multi-element analysis of wines [J].
Almeida, CM ;
Teresa, M ;
Vasconcelos, SD .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :165-175
[2]   UV-irradiation and MW-digestion pre-treatment of Port wine suitable for the determination of lead isotope ratios by inductively coupled plasma mass spectrometry [J].
Almeida, CMR ;
Vasconcelos, MTSD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (12) :1815-1821
[3]   SEMIQUANTITATIVE ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
AMARASIRIWARDENA, CJ ;
GERCKEN, B ;
ARGENTINE, MD ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) :457-462
[4]   Semiquantitative analysis of biological materials by inductively coupled plasma-mass spectrometry [J].
Amarasiriwardena, D ;
Durrant, SF ;
Lasztity, A ;
Krushevska, A ;
Argentine, MD ;
Barnes, RM .
MICROCHEMICAL JOURNAL, 1997, 56 (03) :352-372
[5]   Diagnosing the traffic impact on roadside soils through a multianalytical data analysis of the concentration profiles of traffic-related elements [J].
Antonio Carrero, Jose ;
Arrizabalaga, Iker ;
Bustamante, Julen ;
Goienaga, Naiara ;
Arana, Gorka ;
Manuel Madariaga, Juan .
SCIENCE OF THE TOTAL ENVIRONMENT, 2013, 458 :427-434
[6]   Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer [J].
Augagneur, S ;
Medina, B ;
Szpunar, J ;
Lobinski, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :713-721
[7]  
Balaram V, 2004, ATOM SPECTROSC, V24, P206
[8]  
Baxter MJ, 1997, FOOD CHEM, V60, P443, DOI 10.1016/S0308-8146(96)00365-2
[9]   Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS [J].
Castiñeira, MM ;
Brandt, R ;
von Bohlen, A ;
Jakubowski, N .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) :553-558
[10]   Room temperature acid sonication ICP-MS multielemental analysis of milk [J].
Cava-Montesinos, P ;
Cervera, ML ;
Pastor, A ;
de la Guardia, M .
ANALYTICA CHIMICA ACTA, 2005, 531 (01) :111-123