Capillary ion electrophoresis of inorganic anions and uric acid in human saliva using a polyvinyl alcohol coated capillary column and hexamethonium chloride as additive of background electrolyte

被引:19
|
作者
Mori, Masanobu [1 ]
Yamamoto, Tsukasa [1 ]
Kaseda, Maid [1 ]
Yamada, Sachiko [1 ]
Itabashi, Hideyuki [1 ]
机构
[1] Gunma Univ, Grad Sch Engn, Dept Chem & Chem Biol, Kiryu, Gunma 3768515, Japan
基金
日本学术振兴会;
关键词
Capillary ion electrophoresis; PVA capillary; Hexamethonium dichloride; Human saliva; Inorganic anions; Uric acid; ZONE-ELECTROPHORESIS; HUMAN SERUM; NITRATE; NITRITE; FLOW; CHROMATOGRAPHY; THIOCYANATE; STRESS;
D O I
10.1016/j.jchromb.2011.12.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A combination of polyvinyl alcohol chemically coated capillary (PVA capillary) and background electrolyte (BGE)with ion-pair reagent (hexamethonium dichloride, HMC) was used on capillary ion electrophoresis-UV detection (CIE-UV) for analysis of Br-, I-, NO2-, NO3-, SCN- and uric acid in human saliva. The PVA capillary prepared in our laboratory minimized electro-osmotic flow (EOF) at the BGE in pH 3-10, and did not affect the UV detection at 210 nm by the PVA-layer on capillary wall. Therefore, use of the PVA capillary was suitable for sensitive UV detection for analyte anions, as well as suppression of protein adsorption. In this study, we optimized the BGE of 10 mM phosphate plus 10 mM HMC with applying a voltage of -15 kV. HMC as an additive to BGE could manipulate the electrophoretic mobility of anions, without electrostatic adsorption to the PVA capillary. The CIE-UV could separate and determine analyte anions in human saliva containing proteins by the direct injection without pretreatments such as dilution or deproteinization within 13 min. The relative standard deviations (n = 10) were ranged of 0.5-1.6% in migration times, 2.2-6.8% in peak heights and 2.8-8.4% in peak areas. The limits of detection (S/N =3) were ranged of 3.42-6.87 mu M. The peak height of anions in this system was gradually decreased through the successive injections of saliva samples, but the problem was successfully solved by periodically conditioning the PVA capillary. The quantifiability of anions in human saliva samples by the CIE-UV was evaluated through the recoveries by standard addition methods and comparison of other representative analytical methods, as well as identification by ion chromatography (IC). From the anion analyses in 12 different saliva samples, the CIE-UV demonstrated that can obtain obvious differences in concentrations of SCN- between of smoker and non-smoker and those of uric acid between male and female with satisfactory results. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 11 条
  • [1] Capillary ion electrophoresis–capacitively coupled contactless conductivity detection of inorganic cations in human saliva on a polyvinyl alcohol-coated capillary
    Masanobu Mori
    Maki Kaseda
    Tsukasa Yamamoto
    Sachiko Yamada
    Hideyuki Itabashi
    Analytical and Bioanalytical Chemistry, 2012, 402 : 2425 - 2430
  • [2] Capillary ion electrophoresis-capacitively coupled contactless conductivity detection of inorganic cations in human saliva on a polyvinyl alcohol-coated capillary
    Mori, Masanobu
    Kaseda, Maki
    Yamamoto, Tsukasa
    Yamada, Sachiko
    Itabashi, Hideyuki
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (07) : 2425 - 2430
  • [3] Determination of Uric Acid in Human Saliva and Urine Using Miniaturized Capillary Electrophoresis with Amperometric Detection
    Q. C. Chu
    M. Lin
    C. H. Geng
    J. N. Ye
    Chromatographia, 2007, 65 : 179 - 184
  • [4] Determination of uric acid in human saliva and urine using miniaturized capillary electrophoresis with amperometric detection
    Chu, Q. C.
    Lin, M.
    Geng, C. H.
    Ye, J. N.
    CHROMATOGRAPHIA, 2007, 65 (3-4) : 179 - 184
  • [5] Orotic acid in clinical urine specimens by capillary zone electrophoresis using polyvinyl alcohol coated capillaries
    Franke, DR
    Nuttall, KL
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1996, 3 (06) : 309 - 312
  • [6] Orotic acid in clinical urine specimens by capillary zone electrophoresis using polyvinyl alcohol coated capillaries.
    Franke, DR
    Nuttall, KL
    CLINICAL CHEMISTRY, 1997, 43 : 440 - 440
  • [7] Determination of Chloride, Inorganic Phosphate, and Citric Acid in Human Serum Using Capillary Zone Electrophoresis
    Kita, Kenji
    Fukushi, Keiichi
    Hiraoka, Atsushi
    Suzuki, Yoshifumi
    Soejima, Akinori
    Miyado, Takashi
    BUNSEKI KAGAKU, 2011, 60 (08) : 671 - 674
  • [8] Performance of a simple UV LED light source in the capillary electrophoresis of inorganic anions with indirect detection using a chromate background electrolyte
    King, M
    Paull, B
    Haddad, PR
    Macka, M
    ANALYST, 2002, 127 (12) : 1564 - 1567
  • [9] DETERMINATION OF MONOVALENT INORGANIC ANIONS IN HUMAN SALIVA BY ION CHROMATOGRAPHY USING MICROCOLUMN COATED WITH MICELLAR ZWITTERIONIC BILE-ACID DERIVATIVE
    HU, WZ
    HARAGUCHI, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1993, 66 (05) : 1420 - 1423
  • [10] Determination of uric acid and p-aminohippuric acid in human saliva and urine using capillary electrophoresis with electrochemical detection -: Potential application in fast diagnosis of renal disease
    Guan, YQ
    Wu, T
    Ye, JN
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 821 (02): : 229 - 234