Projection-based motion compensation for gated coronary artery reconstruction from rotational x-ray angiograms

被引:49
作者
Hansis, E. [1 ,2 ]
Schaefer, D. [1 ]
Doessel, O. [2 ]
Grass, M. [1 ]
机构
[1] Philips Res Europe Hamburg, Sector Med Imaging Syst, D-22335 Hamburg, Germany
[2] Univ Karlsruhe, Inst Biomed Engn, D-76131 Karlsruhe, Germany
关键词
D O I
10.1088/0031-9155/53/14/007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional reconstruction of coronary arteries can be performed during x-ray-guided interventions by gated reconstruction from a rotational coronary angiography sequence. Due to imperfect gating and cardiac or breathing motion, the heart's motion state might not be the same in all projections used for the reconstruction of one cardiac phase. The motion state inconsistency causes motion artefacts and degrades the reconstruction quality. These effects can be reduced by a projection-based 2D motion compensation method. Using maximum-intensity forward projections of an initial uncompensated reconstruction as reference, the projection data are transformed elastically to improve the consistency with respect to the heart's motion state. A fast iterative closest-point algorithm working on vessel centrelines is employed for estimating the optimum transformation. Motion compensation is carried out prior to and independently from a final reconstruction. The motion compensation improves the accuracy of reconstructed vessel radii and the image contrast in a software phantom study. Reconstructions of human clinical cases are presented, in which the motion compensation substantially reduces motion blur and improves contrast and visibility of the coronary arteries.
引用
收藏
页码:3807 / 3820
页数:14
相关论文
共 21 条
[1]  
[Anonymous], 2001, Proc. British Machine Vision Conference
[2]   Reconstruction of coronary arteries from a single rotational X-ray projection sequence [J].
Blondel, C ;
Malandain, G ;
Vaillant, R ;
Ayache, N .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (05) :653-663
[3]   HIERARCHICAL CHAMFER MATCHING - A PARAMETRIC EDGE MATCHING ALGORITHM [J].
BORGEFORS, G .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1988, 10 (06) :849-865
[4]  
Bovik AC., 2000, HDB IMAGE VIDEO PROC
[6]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[7]  
García-Alvarez J, 2006, SARCOIDOSIS VASC DIF, V23, P13
[8]  
HANSIS E, 2007, P SPIE MED IMAGING P, V6510
[9]  
JANDT U, 2007, P SPIE MED IMAGING P, V6510
[10]   A quantitative evaluation of the three dimensional reconstruction of patients' coronary arteries [J].
Klein, JL ;
Hoff, JG ;
Peifer, JW ;
Folks, R ;
Cooke, CD ;
King, SB ;
Garcia, EV .
INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 1998, 14 (02) :75-87