Endosteal Strut Augment Reduces Complications Associated With Proximal Humeral Locking Plates

被引:79
作者
Neviaser, Andrew S. [1 ]
Hettrich, Carolyn M. [1 ]
Beamer, Brandon S. [3 ]
Dines, Joshua S. [2 ]
Lorich, Dean G. [1 ]
机构
[1] Hosp Special Surg, Orthopaed Trauma Serv, New York, NY 10021 USA
[2] Hosp Special Surg, Sports Med & Shoulder Serv, New York, NY 10021 USA
[3] Weill Cornell Med Coll, New York, NY USA
关键词
AVASCULAR NECROSIS; INTERNAL-FIXATION; COMPLEX FRACTURES; OPEN REDUCTION; LOCKED PLATE; HEMIARTHROPLASTY; SHOULDER; HEAD; CLASSIFICATION; IMPLANT;
D O I
10.1007/s11999-011-1949-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Locking-plate technology has renewed interest in plate fixation for treating proximal humerus fractures. Complications associated with these devices, including loss of reduction, screw cutout, and intra-articular penetration, are frequent. Establishing a second column of support may reduce complications and improve clinical outcome scores. We asked whether addition of an endosteal cortical allograft strut, used as an augment to locking-plate fixation for displaced proximal humerus fractures, would reduce complications and improve clinical outcome scores. We retrospectively reviewed the charts and radiographs of 38 patients treated by this method. All patients were evaluated with serial radiographs, as well as the Disabilities of the Arm, Shoulder, and Hand and Constant-Murley scores. There were seven two-part, 19 three-part, and 12 four-part fractures. The minimum followup was 49 weeks (average, 75 weeks; range, 49-155 weeks). No patient had intra-articular screw penetration or cutout. No patient had complete osteonecrosis, but one had partial osteonecrosis. The reduction was lost in one patient. The mean Disabilities of the Arm, Shoulder, and Hand score was 15 (range, 0-66.4). The mean Constant-Murley score was 87 (range, 51-95). Low rates of complication and high clinical outcome scores can be achieved when treating complex proximal humerus fractures with locking-plate fixation and an endosteal strut augment. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:3300 / 3306
页数:7
相关论文
共 36 条
  • [31] Cement augmentation of humeral head screws reduces early implant-related complications after locked plating of proximal humeral fractures
    Katthagen, J. Christoph
    Lutz, O.
    Voigt, C.
    Lill, H.
    Ellwein, A.
    OBERE EXTREMITAET-SCHULTER-ELLENBOGEN-HAND-UPPER EXTREMITY-SHOULDER ELBOW HAND, 2018, 13 (02): : 123 - 129
  • [32] Calcaneal fracture fixation using a new interlocking nail reduces complications compared to standard locking plates - Prelimeinary results after 1.6 years
    Herlyn, Anica
    Brakelmann, Anna
    Herlyn, Philipp K. E.
    Gradl, Georg
    Mittlmeier, Thomas
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 : 63 - 68
  • [33] Early locking plate removal following open reduction and internal fixation of proximal humeral fractures could prevent secondary implant-related complications
    Dimitriou, Dimitris
    Waldmann, Soeren
    Antoniadis, Alexander
    Liebhauser, Martin
    Helmy, Naeder
    Riede, Ulf
    JOURNAL OF ORTHOPAEDICS, 2020, 17 : 106 - 109
  • [34] Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures-results of an international multicentre study
    Konrad, Gerhard
    Hirschmueller, Anja
    Audige, Laurent
    Lambert, Simon
    Hertel, Ralf
    Suedkamp, Norbert P.
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (05) : 1051 - 1058
  • [35] Complications and morbidity of the extended delto-pectoral approach in treating complex humeral shaft fractures with proximal metaphyseal extension using a long locking plate for internal fixation
    Rechsteiner, Jan
    Grieb, Maximilian
    Zdravkovic, Vilijam
    Spross, Christian
    Jost, Bernhard
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [36] Cement augmentation of humeral head screws reduces early implant-related complications after locked plating of proximal humeral fractures; [Zementaugmentation der Humeruskopfschrauben reduziert frühe, implantatassoziierte Komplikationen nach winkelstabiler Plattenosteosynthese dislozierter proximaler Humerusfrakturen]
    Katthagen J.C.
    Lutz O.
    Voigt C.
    Lill H.
    Ellwein A.
    Obere Extremität, 2018, 13 (2) : 123 - 129