Endosteal Strut Augment Reduces Complications Associated With Proximal Humeral Locking Plates

被引:79
|
作者
Neviaser, Andrew S. [1 ]
Hettrich, Carolyn M. [1 ]
Beamer, Brandon S. [3 ]
Dines, Joshua S. [2 ]
Lorich, Dean G. [1 ]
机构
[1] Hosp Special Surg, Orthopaed Trauma Serv, New York, NY 10021 USA
[2] Hosp Special Surg, Sports Med & Shoulder Serv, New York, NY 10021 USA
[3] Weill Cornell Med Coll, New York, NY USA
关键词
AVASCULAR NECROSIS; INTERNAL-FIXATION; COMPLEX FRACTURES; OPEN REDUCTION; LOCKED PLATE; HEMIARTHROPLASTY; SHOULDER; HEAD; CLASSIFICATION; IMPLANT;
D O I
10.1007/s11999-011-1949-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Locking-plate technology has renewed interest in plate fixation for treating proximal humerus fractures. Complications associated with these devices, including loss of reduction, screw cutout, and intra-articular penetration, are frequent. Establishing a second column of support may reduce complications and improve clinical outcome scores. We asked whether addition of an endosteal cortical allograft strut, used as an augment to locking-plate fixation for displaced proximal humerus fractures, would reduce complications and improve clinical outcome scores. We retrospectively reviewed the charts and radiographs of 38 patients treated by this method. All patients were evaluated with serial radiographs, as well as the Disabilities of the Arm, Shoulder, and Hand and Constant-Murley scores. There were seven two-part, 19 three-part, and 12 four-part fractures. The minimum followup was 49 weeks (average, 75 weeks; range, 49-155 weeks). No patient had intra-articular screw penetration or cutout. No patient had complete osteonecrosis, but one had partial osteonecrosis. The reduction was lost in one patient. The mean Disabilities of the Arm, Shoulder, and Hand score was 15 (range, 0-66.4). The mean Constant-Murley score was 87 (range, 51-95). Low rates of complication and high clinical outcome scores can be achieved when treating complex proximal humerus fractures with locking-plate fixation and an endosteal strut augment. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:3300 / 3306
页数:7
相关论文
共 36 条
  • [21] Geriatric proximal humeral fracture patients show similar clinical outcomes to non-geriatric patients after osteosynthesis with endosteal fibular strut allograft augmentation
    Hinds, Richard M.
    Garner, Matthew R.
    Tran, Wesley H.
    Lazaro, Lionel E.
    Dines, Joshua S.
    Lorich, Dean G.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (06) : 889 - 896
  • [22] INTERNAL FIXATION WITH LOCKING PLATE OF 3-AND 4-PART PROXIMAL HUMERAL FRACTURES IN ELDERLY PATIENTS: COMPLICATIONS AND FUNCTIONAL OUTCOME
    Matejcic, Aljosa
    Vidovic, Dinko
    Ivica, Mihovil
    Durdevic, Dragan
    Tomljenovic, Mladen
    Bekavac-Beslin, Miroslav
    Mijic, August
    Punda, Marija
    Bakota, Bore
    Misir, Zvonimir
    ACTA CLINICA CROATICA, 2013, 52 (01) : 17 - 22
  • [23] A practical guide for the use of contour locking plates for the repair of humeral diaphyseal fractures with proximal extension
    Zamboni, Caio
    Carmo, Bruno L.
    Moraes, Leonardo V. M.
    Hungria, Jose O. S.
    Mercadante, Marcelo T.
    Fucs, Patricia M. M. B.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (12): : 2247 - 2251
  • [24] A Standardized Operative Protocol for Fixation of Proximal Humeral Fractures Using a Locking Plate to Minimize Surgery-Related Complications
    Kwisda, Sebastian
    Imiolczyk, Jan-Philipp
    Imiolczyk, Tankred
    Werth, Magdalena
    Scheibel, Markus
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (03)
  • [25] Relationship between the Axillary Nerve and Accompanying Vessels and Proximal Humeral Locking Plates in Japanese: An MRI Study
    Sakoma, Yoshimasa
    Hirooka, Takahiko
    ACTA MEDICA OKAYAMA, 2017, 71 (06) : 525 - 529
  • [26] Efficacy comparison of intramedullary nails, locking plates and conservative treatment for displaced proximal humeral fractures in the elderly
    Ge, Wei
    Sun, Qi
    Li, Gen
    Lu, Guanghua
    Cai, Ming
    Li, Shaohua
    CLINICAL INTERVENTIONS IN AGING, 2017, 12 : 2047 - 2054
  • [27] Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures
    Schliemann, Benedikt
    Seifert, Robert
    Rosslenbroich, Steffen B.
    Theisen, Christina
    Waehnert, Dirk
    Raschke, Michael J.
    Weimann, Andre
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (12) : 1968 - 1973
  • [28] Cross-elements to enhance fixation in osteoporotic bone with application to proximal humeral locking plates: a biomechanical study
    Gonzalez-Hernandez, Eduardo
    Pietrzak, William S.
    Jain, Saaransh
    Lapica, Hans E.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (08) : 1606 - 1614
  • [29] Serial changes in the head-shaft angle of proximal humeral fractures treated by placing locking plates: a retrospective study
    Wang, Ji-Qi
    Jiang, Bing-Jie
    Guo, Wei-Jun
    Zhao, You-Ming
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [30] Straight and helical plating with locking plates for proximal humeral shaft fractures - a biomechanical comparison under physiological load conditions
    Halbauer, Christian
    Capanni, Felix
    Paech, Andreas
    Knop, Christian
    Merkle, Tobias
    Da Silva, Tomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024,