A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator

被引:97
|
作者
Iijima, T [1 ]
Korpar, S
Adachi, I
Fratina, S
Fukushima, T
Gorisek, A
Kawai, H
Konishi, H
Kozakai, Y
Krizan, P
Matsumoto, T
Mazuka, Y
Nishida, S
Ogawa, S
Ohtake, S
Pestotnik, R
Saitoh, S
Seki, T
Sumiyoshi, T
Uchida, Y
Unno, Y
Yamamoto, S
机构
[1] Univ Ljubljana, Fac Math & Phys, Ljubljana 61000, Slovenia
[2] Nagoya Univ, Nagoya, Aichi, Japan
[3] Univ Maribor, Fac Chem & Chem Engn, SLO-2000 Maribor, Slovenia
[4] Jozef Stefan Inst, Ljubljana, Slovenia
[5] High Energy Accelerator Res Org, KEK, Tsukuba, Ibaraki, Japan
[6] Chiba Univ, Chiba, Japan
[7] Tokyo Metropolitan Univ, Tokyo 158, Japan
[8] Toho Univ, Funabashi, Chiba 274, Japan
关键词
ring imaging Cherenkov counter; proximity focusing; aerogel; particle identification; Belle;
D O I
10.1016/j.nima.2005.05.030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A proximity focusing ring imaging Cherenkov detector, with the radiator consisting of two or more aerogel layers of different refractive indices, has been tested in 1-4GeV/c pion beams at KEK. Essentially, a multiple refractive index aerogel radiator allows for an increase in Cherenkov photon yield on account of the increase in overall radiator thickness, while avoiding the simultaneous degradation in single photon angular resolution associated with the increased uncertainty of the emission point. With the refractive index of consecutive layers suitably increasing in the downstream direction, one may achieve overlapping of the Cherenkov rings from a single charged particle. In the opposite case of decreasing refractive index, one may obtain well separated rings. In the former combination an approximately 40% increase in photon yield is accompanied with just a minor degradation in single photon angular resolution. The impact of this improvement on the pi/K separation at the upgraded Belle detector is discussed. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:383 / 390
页数:8
相关论文
共 17 条
  • [1] A novel type of proximity focusing RICH counter with multiple refractive index aerogel radiator
    Korpar, S.
    Adachi, I.
    Fujita, K.
    Fukushima, T.
    Gorisek, A.
    Hayashi, D.
    Iijima, T.
    Ikado, T.
    Ishikawa, T.
    Kawai, H.
    Kozakai, Y.
    Krizan, P.
    Kuratani, A.
    Mazuka, Y.
    Nakagawa, T.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Seki, T.
    Sumiyoshi, T.
    Tabata, M.
    Unno, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 572 (01) : 429 - 431
  • [2] Studies of a proximity focusing RICH with aerogel radiator
    Matsumoto, T
    Korpar, S
    Adachi, I
    Fratina, S
    Iijima, T
    Ishibashi, R
    Kawai, H
    Krizan, P
    Ogawa, S
    Pestotnik, R
    Saitoh, S
    Seki, T
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    Uchida, Y
    Unno, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2) : 582 - 585
  • [3] Tests of a proximity focusing RICH with aerogel as radiator
    Iijima, T
    Adachi, I
    Bizjak, I
    Gorisek, A
    Iwamoto, M
    Korpar, S
    Krizan, P
    Pestotnik, R
    Staric, M
    Stanovnik, A
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 502 (01) : 231 - 235
  • [4] Study of a proximity focusing RICH with a silica aerogel radiator
    Adachi, I.
    Fujita, K.
    Fukushima, T.
    Gorisek, A.
    Hayashi, D.
    Iijima, T.
    Ikado, T.
    Ishikawa, T.
    Kawai, H.
    Korpar, S.
    Kozakai, Y.
    Krizan, P.
    Kuratani, A.
    Mazuka, Y.
    Nakagawa, T.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Seki, T.
    Sumiyoshi, T.
    Tabata, M.
    Unno, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2) : 415 - 418
  • [5] A study of proximity focusing RICH with aerogel radiator
    Adachi, I.
    Fujita, K.
    Fukushima, T.
    Gorisek, A.
    Hayashi, D.
    Iijima, T.
    Ikado, T.
    Ishikawa, T.
    Kawai, H.
    Korpar, S.
    Kozakai, Y.
    Krizan, P.
    Kuratani, A.
    Mazuka, Y.
    Nakagawa, T.
    Nishida, S.
    Ogawa, S.
    Pestotnik, R.
    Seki, T.
    Sumiyoshi, T.
    Tabata, M.
    Unno, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) : 1042 - 1045
  • [6] Study of a nonhomogeneous aerogel radiator in a proximity focusing RICH detector
    Krizan, Peter
    Korpar, Samo
    Iijima, Toru
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 565 (02) : 457 - 462
  • [7] Proximity focusing RICH with flat panel PMT as photon detector and aerogel as radiator
    Krizan, P
    Adachi, I
    Fratina, S
    Fukushima, S
    Gorisek, A
    Iijima, T
    Kawai, H
    Konishi, H
    Korpar, S
    Kozakai, Y
    Matsumoto, T
    Mazuka, Y
    Nishida, S
    Ogawa, S
    Ohtake, S
    Pestotnik, R
    Saitoh, S
    Seki, T
    Sumiyoshi, T
    Uchida, Y
    Unno, Y
    Yamamoto, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 553 (1-2) : 58 - 63
  • [8] RICH with multiple aerogel layers of different refractive index
    Korpar, S
    Adachi, I
    Fratina, S
    Fukushima, T
    Gorisek, A
    Iijima, T
    Kawai, H
    Konishi, H
    Kozakai, Y
    Krizan, P
    Matsumoto, T
    Mazuka, Y
    Nishida, S
    Ogawa, S
    Ohtake, S
    Pestotnik, R
    Saitoh, S
    Seki, T
    Stanovnik, A
    Sumiyoshi, T
    Uchida, Y
    Unno, Y
    Yamamoto, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 553 (1-2) : 64 - 69
  • [9] Tests of a proximity focusing RICH with aerogel as radiator
    Adachi, I
    Bizjak, I
    Gorisek, A
    Iijima, T
    Iwamoto, M
    Korpar, S
    Krizan, P
    Pestotnik, R
    Staric, M
    Stanovnik, A
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (04) : 1142 - 1146
  • [10] Tests of a proximity focusing RICH with aerogel as radiator
    Adachi, I
    Bizjak, I
    Gorisek, A
    Iijima, T
    Iwamoto, M
    Korpar, S
    Krizan, R
    Pestotnik, R
    Staric, M
    Stanovnik, A
    Sumiyoshi, T
    Suzuki, K
    Tabata, T
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 48 - 51