Optimization of biometry for intraocular lens implantation using the Zeiss IOLMaster

被引:22
作者
Madge, SN [1 ]
Khong, CH [1 ]
Lamont, M [1 ]
Bansal, A [1 ]
Antcliff, RJ [1 ]
机构
[1] Royal United Hosp, Dept Ophthalmol, Bath BA1 3NG, Avon, England
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 2005年 / 83卷 / 04期
关键词
biometry; IOLMaster; partial coherence; interferometry; cataract;
D O I
10.1111/j.1600-0420.2005.00486.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the accuracy of biometry using conventional A-scan ultrasonography and partial coherence interferometry, and to improve the accuracy of biometry by sequential audit of postoperative refractive error. Methods: The study was performed in three phases. In phase 1, 20 consecutive patients undergoing routine phaeoemulsification underwent biometry using both A-scan ultrasonography and the Zeiss IOLMaster (ZIOLM). A single experienced optometrist refracted all patients 2 weeks after surgery. The errors between expected and achieved refraction were calculated and compared between the two methods. In phases 2 and 3, a further 22 and 20 patients, respectively, were recruited and only the ZIOLM was used for biometry. The manufacturer's suggested A-constant was refined and the error between expected and achieved refraction was calculated. Results: In phase 1, the median unexpected error for the ZIOLM was + 0.63 (interquartile range + 0.368 to + 1.015) and for A-scan biometry was - 0.24 (interquartile range - 1.335 to + 0.802). In phase 1 65% of patients' postoperative refractions were found to be within 1.0 D of emmetropia using the ZIOLM (55% using A-scan biometry). Refinements to the A-constant improved this to 95% by phase 3. Conclusion: An error was identified in IOL power estimation with the ZIOLM, when using the manufacturer's recommended A-constant (recommended and previously optimized ultrasound A-constant 118.0; ZIOLM optimized A-constant 118.6). Serial modifications to the A-constant were successful in reducing the unexpected error to well within the tolerance limits of published international standards.
引用
收藏
页码:436 / 438
页数:3
相关论文
共 4 条
[1]   Accuracy and reproducibility of biometry using partial coherence interferometry [J].
Connors, R ;
Boseman, P ;
Olson, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :235-238
[2]   THE NATIONAL CATARACT-SURGERY SURVEY .2. CLINICAL OUTCOMES [J].
DESAI, P .
EYE, 1993, 7 :489-494
[3]   National cataract surgery survey 1997-8. A report of the results of the clinical outcomes [J].
Desai, P ;
Minassian, DC ;
Reidy, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1999, 83 (12) :1336-1340
[4]   The Swedish National Cataract Register:: A 9-year review [J].
Lundström, M ;
Stenevi, U ;
Thorburn, W .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 (03) :248-257