Application of a liquid chromatographic/tandem mass spectrometric method to a kinetic study of derivative glucosamine in healthy human urine

被引:15
作者
Guan, Yue [1 ]
Tian, Yun [1 ]
Li, Yan [1 ]
Yang, Zhifu [1 ]
Jia, Yanyan [1 ]
Hang, Taijun [2 ]
Wen, Aidong [1 ]
机构
[1] Fourth Mil Med Univ, Dept Pharm, Xijing Hosp, Xian 710032, Shaanxi, Peoples R China
[2] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
关键词
Glucosamine; LC/MS/MS; Urine; Pharmacokinetics; HUMAN PLASMA; FLUORESCENCE DETECTION; MS/MS METHOD; VALIDATION; SULFATE; ASSAY;
D O I
10.1016/j.jpba.2011.01.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, selective and efficient liquid chromatographic/tandem mass spectrometric (LC/MS/MS) method was developed and validated for the determination of glucosamine in healthy human urine. Urine samples were extracted by acetonitrile and derivatized with o-phthalaldehyde/3-mercaptopropionic acid. Analysis was then carried out using ESI source and methanol/0.2% ammonium acetate-0.1% formic acid mobile phase gradient elution, with tolterodine tartrate as the internal standard. The linear calibration curve ranged from 0.41 mu g/ml to 82.7 mu g/ml. The intra-day and inter-day precisions were less than 3.93% and 10.0%, respectively. The extraction recoveries determined at three concentration levels were higher than 88.6%. The method was successfully applied for determining the urine concentration of glucosamine up to 24 h after oral administration of 1 g glucosamine sulfate dispersible table (containing 785.08 mg glucosamine) from a clinical pharmacokinetic study in healthy volunteers. Published by Elsevier B.V.
引用
收藏
页码:181 / 186
页数:6
相关论文
共 10 条
[1]   Glucosamine effects in humans: a review of effects on glucose metabolism, side effects, safety considerations and efficacy [J].
Anderson, JW ;
Nicolosi, RJ ;
Borzelleca, JF .
FOOD AND CHEMICAL TOXICOLOGY, 2005, 43 (02) :187-201
[2]   Liquid chromatography with electrospray ionization mass spectrometry method for the assay of glucosamine sulfate in human plasma: validation and application to a pharmacokinetic study [J].
Huang, TM ;
Cai, L ;
Yang, B ;
Zhou, MX ;
Shen, YF ;
Duan, GL .
BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (03) :251-256
[3]  
Ibrahim A, 2010, J PHARM PHARM SCI, V13, P128
[4]   Determination of underivatized glucosamine in human plasma by high-performance liquid chromatography with electrochemical detection: Application to pharmacokinetic study [J].
Pashkova, E. ;
Pirogov, A. ;
Bendryshev, A. ;
Ivanaynen, E. ;
Shpigun, O. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (04) :671-674
[5]   Development and validation of a HPLC-ES-MS/MS method for the determination of glucosamine in human synovial fluid [J].
Pastorini, E. ;
Rotini, R. ;
Guardigli, M. ;
Vecchiotti, S. ;
Persiani, S. ;
Trisolino, G. ;
Antonioli, D. ;
Rovati, L. C. ;
Roda, A. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 50 (05) :1009-1014
[6]   Application of capillary zone electrophoresis and reversed-phase high-performance liquid chromatography in the biopharmaceutical industry for the quantitative analysis of the monosaccharides released from a highly glycosylated therapeutic protein [J].
Racaityte, K ;
Kiessig, S ;
Kálmán, F .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :354-365
[7]   Development and validation of a sensitive HPLC-ESI-MS/MS method for the direct determination of glucosamine in human plasma [J].
Roda, Aldo ;
Sabatini, Laura ;
Barbieri, Anna ;
Guardigli, Massimo ;
Locatelli, Marcello ;
Saverio Violante, Francesco ;
Rovati, Lucio C. ;
Persiani, Stefano .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01) :119-126
[8]  
SETNIKAR I, 1986, ARZNEIMITTELFORSCH, V36-1, P729
[9]   An optimized reverse-phase high performance liquid chromatographic method for evaluating percutaneous absorption of glucosamine hydrochloride [J].
Tekko, Ismaiel A. ;
Bonner, Michael C. ;
Williams, Adrian C. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) :385-392
[10]   Determination of glucosamine sulfate in human plasma by precolumn derivatization using high performance liquid chromatography with fluorescence detection: Its application to a bioequivalence study [J].
Zhang, Li-jun ;
Huang, Tao-min ;
Fang, Xiao-ling ;
Li, Xue-ning ;
Wang, Qing-song ;
Zhang, Zhi-wen ;
Sha, Xian-yi .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 842 (01) :8-12