The Likelihood Evaluation of the Heat Exchanger Unit Model Design Method in the Ground Source Heat Pump System Utilizing Heat Exchanger Piles

被引:0
作者
Oguma, Masahito [1 ]
Funabiki, Ayako [1 ]
Satoh, Takashi [1 ]
Kakizaki, Takao [1 ]
机构
[1] Nihon Univ, Coll Engn, Dept Mech Engn, Koriyama, Fukushima 963, Japan
来源
2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA) | 2013年
关键词
Renewable Enegy; Ground Source Heat Pump; Heat Exchanger Piles; Thermal Performance; PERFORMANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A ground source heat pump system (GSHP) utilizing the foundation piles as heat exchangers is expected to reduce the initial cost compared with the borehole type of the conventional system because the heat exchanger piles is not needed to install anew. However, the arrangement of the piles is depend on the floor layout of a residence. Therefore, the thermal performance prediction of heat exchange piles has to strictly conduct three-dimensional analysis for every residence. Conducting such analysis, it is a heavy burden for a designer to perform performance prediction of the GSHP with satisfaction of the annual heating and cooling demand. Then, the two-dimensional heat unit model was proposed in order to ease a designer's burden. This model has the characteristic of originally not using the soil portion where the ground heat source is available. And if it is seemed to be the design likelihood, it makes the designer's load reduce. The introductory possibility of the GSHP, which uses the foundation pile in the semi-cold district of our country, is shown by the numerical analysis using this model. It is necessary to show clearly how much the analytical results calculated by use of this model has likelihood. Then, as compared with the higher-dimensional analysis results, the same heating demand conditions are employed at the thermal prediction. The rectangular and triangle arrangements of piles are inquired for the evaluations. The finite difference method is employed for the numerical analysis. It is shown that the evaluation using the proposed model has an average of 10 - 50% of likelihood compared with the higher dimensional analysis evaluation when single layer of piles surrounds the center piles. In the case of the arrangements in which multi layers of piles surround the center piles, the proposed thermal unit model leads the same analytical results by use of higher dimensional coordinates model.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 50 条
  • [31] Performance optimization of a hybrid ground source heat pump with the parallel configuration of a ground heat exchanger and a supplemental heat rejecter in the cooling mode
    Park, Honghee
    Lee, Joo Seoung
    Kim, Wonuk
    Kim, Yongchan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (06): : 1537 - 1546
  • [32] A numerical study on the sustainability and efficiency of borehole heat exchanger coupled ground source heat pump systems
    Hein, Philipp
    Kolditz, Olaf
    Goerke, Uwe-Jens
    Bucher, Anke
    Shao, Haibing
    APPLIED THERMAL ENGINEERING, 2016, 100 : 421 - 433
  • [33] Working mechanism and application of heat exchanger piles
    Yu Chuang
    Pan Lin-you
    Liu Song-yu
    Cai Yuan-qiang
    ROCK AND SOIL MECHANICS, 2009, 30 (04) : 933 - +
  • [34] Influence of ground source heat exchanger operation modes on multi-borehole mid-deep ground source heat pump system performance
    Wang, Zuohai
    Ding, Jian
    Yu, Mingzhi
    Mao, Yudong
    Zhu, Ke
    Zhang, Wenke
    Cui, Ping
    Zhuang, Zhaoyi
    Zhou, Shiyu
    GEOTHERMICS, 2025, 125
  • [35] Analysis of Groundwater Advection and Ground-Heat Exchanger Spacing on Intermittent Ground-Source Heat Pump Operation
    Lines, Scott Harold
    Llano-Serna, Marcelo A.
    Williams, David J.
    ENERGY GEOTECHNICS, SEG-2018, 2019, : 19 - 26
  • [36] Experimental evaluation of ground heat exchanger in UAE
    Atwany, Hanin
    Hamdan, Mohammad O.
    Abu-Nabah, Bassam A.
    Alami, Abdul Hai
    Attom, Mousa
    RENEWABLE ENERGY, 2020, 159 : 538 - 546
  • [37] A Model of a Diaphragm Wall Ground Heat Exchanger
    Shafagh, Ida
    Rees, Simon
    Urra Mardaras, Inigo
    Curto Jano, Marina
    Polo Carbayo, Merche
    ENERGIES, 2020, 13 (02)
  • [38] Evaluation of estimation method of ground properties for the ground source heat pump system
    Hwang, Suckho
    Ooka, Ryozo
    Nam, Yujin
    RENEWABLE ENERGY, 2010, 35 (09) : 2123 - 2130
  • [39] On the sizing of a novel Flat-Panel ground heat exchanger in coupling with a dual-source heat pump
    Bottarelli, M.
    Bortoloni, M.
    Su, Y.
    RENEWABLE ENERGY, 2019, 142 : 552 - 560
  • [40] An investigation of the heat pump performance and ground temperature of a piled foundation heat exchanger system for a residential building
    Wood, Christopher J.
    Liu, Hao
    Riffat, Saffa B.
    ENERGY, 2010, 35 (12) : 4932 - 4940