The Likelihood Evaluation of the Heat Exchanger Unit Model Design Method in the Ground Source Heat Pump System Utilizing Heat Exchanger Piles

被引:0
作者
Oguma, Masahito [1 ]
Funabiki, Ayako [1 ]
Satoh, Takashi [1 ]
Kakizaki, Takao [1 ]
机构
[1] Nihon Univ, Coll Engn, Dept Mech Engn, Koriyama, Fukushima 963, Japan
来源
2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA) | 2013年
关键词
Renewable Enegy; Ground Source Heat Pump; Heat Exchanger Piles; Thermal Performance; PERFORMANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A ground source heat pump system (GSHP) utilizing the foundation piles as heat exchangers is expected to reduce the initial cost compared with the borehole type of the conventional system because the heat exchanger piles is not needed to install anew. However, the arrangement of the piles is depend on the floor layout of a residence. Therefore, the thermal performance prediction of heat exchange piles has to strictly conduct three-dimensional analysis for every residence. Conducting such analysis, it is a heavy burden for a designer to perform performance prediction of the GSHP with satisfaction of the annual heating and cooling demand. Then, the two-dimensional heat unit model was proposed in order to ease a designer's burden. This model has the characteristic of originally not using the soil portion where the ground heat source is available. And if it is seemed to be the design likelihood, it makes the designer's load reduce. The introductory possibility of the GSHP, which uses the foundation pile in the semi-cold district of our country, is shown by the numerical analysis using this model. It is necessary to show clearly how much the analytical results calculated by use of this model has likelihood. Then, as compared with the higher-dimensional analysis results, the same heating demand conditions are employed at the thermal prediction. The rectangular and triangle arrangements of piles are inquired for the evaluations. The finite difference method is employed for the numerical analysis. It is shown that the evaluation using the proposed model has an average of 10 - 50% of likelihood compared with the higher dimensional analysis evaluation when single layer of piles surrounds the center piles. In the case of the arrangements in which multi layers of piles surround the center piles, the proposed thermal unit model leads the same analytical results by use of higher dimensional coordinates model.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 50 条
  • [21] Experimental Study Of Heating-cooling Combined Ground Source Heat Pump System with Horizontal Ground Heat Exchanger
    Hu, Ying-Ning
    Peng, Ban-Jun
    Hu, Shan-Shan
    Lin, Jun
    SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 398 - 404
  • [22] Optimization of ground heat exchanger of the ground source heat pump system based on exergetic analysis using Taguchi technique
    Ahmad, Saif Nawaz
    Prakash, Om
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2021, 235 (21) : 5892 - 5901
  • [23] A novel shallow bore ground heat exchanger for ground source heat pump applications-Model development and validation
    Warner, Joseph
    Liu, Xiaobing
    Shi, Liang
    Qu, Ming
    Zhang, Mingkan
    APPLIED THERMAL ENGINEERING, 2020, 164
  • [24] Simulation of a domestic ground source heat pump system using a three-dimensional numerical borehole heat exchanger model
    He, Miaomiao
    Rees, Simon
    Shao, Li
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2011, 4 (02) : 141 - 155
  • [25] Applicability of the pipe structure and flow velocity of vertical ground heat exchanger for ground source heat pump
    Zhou, Hong
    Lv, Jian
    Li, Tailu
    ENERGY AND BUILDINGS, 2016, 117 : 109 - 119
  • [26] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717
  • [27] Efficiency and economic analysis of utilizing latent heat from groundwater freezing in the context of borehole heat exchanger coupled ground source heat pump systems
    Zheng, Tianyuan
    Shao, Haibing
    Schelenz, Sophie
    Hein, Philipp
    Vienken, Thomas
    Pang, Zhonghe
    Kolditz, Olaf
    Nagel, Thomas
    APPLIED THERMAL ENGINEERING, 2016, 105 : 314 - 326
  • [28] Optimal design of a hybrid ground source heat pump for an official building with thermal load imbalance and limited space for the ground heat exchanger
    Cruz-Peragon, F.
    Cruz, F. J. Gomez-de la
    Palomar-Carnicero, J. M.
    Lopez-Garcia, R.
    RENEWABLE ENERGY, 2022, 195 : 381 - 394
  • [29] Efficiency analysis of utilizing phase change materials as grout for a vertical U-tube heat exchanger coupled ground source heat pump system
    Chen, Fei
    Mao, Jinfeng
    Chen, Shangyuan
    Li, Chaofeng
    Hou, Pumin
    Liao, Lu
    APPLIED THERMAL ENGINEERING, 2018, 130 : 698 - 709
  • [30] A NEW-STYLE GROUND-SOURCE HEAT EXCHANGER AND THE HEAT TRANSFER MODEL
    Zhou, You
    Gong, Guangcai