The Likelihood Evaluation of the Heat Exchanger Unit Model Design Method in the Ground Source Heat Pump System Utilizing Heat Exchanger Piles

被引:0
作者
Oguma, Masahito [1 ]
Funabiki, Ayako [1 ]
Satoh, Takashi [1 ]
Kakizaki, Takao [1 ]
机构
[1] Nihon Univ, Coll Engn, Dept Mech Engn, Koriyama, Fukushima 963, Japan
来源
2013 INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA) | 2013年
关键词
Renewable Enegy; Ground Source Heat Pump; Heat Exchanger Piles; Thermal Performance; PERFORMANCE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A ground source heat pump system (GSHP) utilizing the foundation piles as heat exchangers is expected to reduce the initial cost compared with the borehole type of the conventional system because the heat exchanger piles is not needed to install anew. However, the arrangement of the piles is depend on the floor layout of a residence. Therefore, the thermal performance prediction of heat exchange piles has to strictly conduct three-dimensional analysis for every residence. Conducting such analysis, it is a heavy burden for a designer to perform performance prediction of the GSHP with satisfaction of the annual heating and cooling demand. Then, the two-dimensional heat unit model was proposed in order to ease a designer's burden. This model has the characteristic of originally not using the soil portion where the ground heat source is available. And if it is seemed to be the design likelihood, it makes the designer's load reduce. The introductory possibility of the GSHP, which uses the foundation pile in the semi-cold district of our country, is shown by the numerical analysis using this model. It is necessary to show clearly how much the analytical results calculated by use of this model has likelihood. Then, as compared with the higher-dimensional analysis results, the same heating demand conditions are employed at the thermal prediction. The rectangular and triangle arrangements of piles are inquired for the evaluations. The finite difference method is employed for the numerical analysis. It is shown that the evaluation using the proposed model has an average of 10 - 50% of likelihood compared with the higher dimensional analysis evaluation when single layer of piles surrounds the center piles. In the case of the arrangements in which multi layers of piles surround the center piles, the proposed thermal unit model leads the same analytical results by use of higher dimensional coordinates model.
引用
收藏
页码:680 / 685
页数:6
相关论文
共 50 条
  • [1] Optimized Design of Ground-Source Heat Pump System Heat Exchanger
    Shi, Zhigang
    Song, Shangping
    Hu, Songtao
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 723 - 730
  • [2] Evaluation of a transient borehole heat exchanger model in dynamic simulation of a ground source heat pump system
    Biglarian, Hassan
    Abbaspour, Madjid
    Saidi, Mohammad Hassan
    ENERGY, 2018, 147 : 81 - 93
  • [3] Operation characteristics and experience of a ground source heat pump system with a vertical ground heat exchanger
    Michopoulos, A.
    Zachariadis, T.
    Kyriakis, N.
    ENERGY, 2013, 51 : 349 - 357
  • [4] Using a capillary mat as a shallow heat exchanger for a ground source heat pump system
    Widiatmojo, Arif
    Gaurav, Shrestha
    Ishihara, Takeshi
    Yasukawa, Kasumi
    Uchida, Youhei
    Yoshioka, Mayumi
    Tomigashi, Akira
    ENERGY AND BUILDINGS, 2020, 209
  • [6] Optimization of ground heat exchanger parameters of ground source heat pump system for space heating applications
    Sivasakthivel, T.
    Murugesan, K.
    Sahoo, P. K.
    ENERGY, 2014, 78 : 573 - 586
  • [7] Experimental and numerical investigation on a new type of heat exchanger in ground source heat pump system
    Liu, Xichen
    Xiao, Yimin
    Inthavong, Kiao
    Tu, Jiyuan
    ENERGY EFFICIENCY, 2015, 8 (05) : 845 - 857
  • [8] Evaluation of stainless steel pipe performance as a ground heat exchanger in ground-source heat-pump system
    Yoon, Seok
    Lee, Seung-Rae
    Kim, Min-Jun
    Kim, Woo-Jin
    Kim, Geon-Young
    Kim, Kyungsu
    ENERGY, 2016, 113 : 328 - 337
  • [9] Effect of a superheating and sub-cooling heat exchanger to the performance of a ground source heat pump system
    Bakirci, Kadir
    Colak, Derya
    ENERGY, 2012, 44 (01) : 996 - 1004
  • [10] Influence of hydration heat on heat transfer effect of ground heat exchanger of ground source heat pump in summer
    Xia, Caichu
    Liu, Zhifang
    Xiao, Suguang
    Huang, Man
    Tongji Daxue Xuebao/Journal of Tongji University, 2015, 43 (09): : 1332 - 1338