Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values

被引:19
作者
Bartolotta, Tommaso Vincenzo [1 ,2 ]
Orlando, Alessia Angela Maria [1 ]
Dimarco, Mariangela [2 ]
Zarcaro, Calogero [1 ]
Ferraro, Fabiola [1 ]
Cirino, Alessandra [1 ]
Matranga, Domenica [3 ]
Vieni, Salvatore [4 ]
Cabibi, Daniela [5 ]
机构
[1] Univ Hosp Policlin P Giaccone, Dept Biomed Neurosci & Adv Diagnost BiND, Via Vespro 129, I-90127 Palermo, Italy
[2] Fdn Ist G Giglio, Cefalu, PA, Italy
[3] Univ Hosp Policlin P Giaccone, Dept Hlth Promot & Mother & Child Care Internal M, Palermo, Italy
[4] Univ Hosp Policlin P Giaccone, Dept Surg Oncol & Oral Sci, Div Gen & Oncol Surg, Palermo, Italy
[5] Univ Hosp Policlin P Giaccone, Dept Hlth Promot Mother & Child Care Internal Med, Anat Pathol Unit, Palermo, Italy
来源
RADIOLOGIA MEDICA | 2022年 / 127卷 / 11期
关键词
Breast; Ultrasonography; Elasticity imaging techniques; Shear wave imaging; ULTRASOUND ELASTOGRAPHY; QUANTITATIVE PARAMETERS; DIFFERENTIAL-DIAGNOSIS; EFSUMB GUIDELINES; SHEAR; LESIONS; RECOMMENDATIONS; BENIGN; STRAIN; ULTRASONOGRAPHY;
D O I
10.1007/s11547-022-01546-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the role of 2D-shear wave elastography (2D-SWE) in differentiating benign from malignant focal breast lesions (FBLs), providing new vendor-specific cutoff values. Methods 158 FBLs (size: 3.5-50 mm) detected in 151 women (age: 21-87 years) were prospectively evaluated by means 2D-SWE. For each lesion, an expert radiologist assessed US BI-RADS category and calculated the following four 2D-SWE parameters: (1) elasticity maximum (E-max); (2) mean elasticity (E-mean); (3) minimum elasticity (E-min); (4) elasticity ratio (E-ratio). US-guided core-biopsy was considered as standard of reference for all the FBLs classified as BI-RADS 4 or 5. For each 2D-SWE parameter, the optimal cutoff value for a diagnostic test was calculated using the Youden method. Diagnostic performance of the US BI-RADS and 2D-SWE parameters was calculated accordingly. Results 83/158 (52.5%) FBLs were benign and 75/158 (47.5%) were malignant. Statistically significant higher stiffness values were observed in malignant FBLs for all 2D-SWE parameters than in benign ones (p < 0.001). 2D-SWE cutoff values were 82.6 kPa, 66.0 kPa and 53.6 kPa, respectively, for E-max, E-mean, E-min and 330.8% for E-ratio. The 2D-SWE parameter showing the best diagnostic accuracy was E-max (85.44%). Considering US BI-RADS 3 (n = 60) and 4a (n = 32) FBLs, E-max and E-mean showed the best diagnostic accuracy (85.87% for both), without a statistically significant decrease in sensitivity (p = 0.7003 and p = 1, respectively). Conclusion Our study provides new vendor-specific cutoff values for 2D-SWE, suggesting its possible clinical use in the adjunctive assessment of category US-BI-RADS 3 and 4a breast masses.
引用
收藏
页码:1209 / 1220
页数:12
相关论文
共 41 条
[21]   Potential role of shear-wave ultrasound elastography for the differential diagnosis of breast non-mass lesions: preliminary report [J].
Ko, Kyung Hee ;
Jung, Hae Kyoung ;
Kim, So Joong ;
Kim, Hyerin ;
Yoon, Jung Hyun .
EUROPEAN RADIOLOGY, 2014, 24 (02) :305-311
[22]  
Krouskop T A, 1987, J Rehabil Res Dev, V24, P1
[23]   Role of shear-wave elastography (SWE) in complex cystic and solid breast lesions in comparison with conventional ultrasound [J].
Lee, Bo Eun ;
Chung, Jin ;
Cha, Eun-Suk ;
Lee, Jee Eun ;
Kim, Jeoung Hyun .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) :1236-1241
[24]   Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses [J].
Lee, Eun Ji ;
Chang, Yun-Woo .
KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (09) :1045-1054
[25]   Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses? [J].
Lee, Eun Jung ;
Jung, Hae Kyoung ;
Ko, Kyung Hee ;
Lee, Jong Tae ;
Yoon, Jung Hyun .
EUROPEAN RADIOLOGY, 2013, 23 (07) :1803-1811
[26]   Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements [J].
Lee, Jihyuk ;
Kang, Hyo-Jin ;
Yoon, Jeong Hee ;
Lee, Jeong Min .
ULTRASONOGRAPHY, 2021, 40 (02) :217-227
[27]  
Mendelson EB, 2013, ACR BI-RADS atlas, Breast Imaging Reporting and Data System
[28]   Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass [J].
Park, Jiyoon ;
Woo, Ok Hee ;
Shin, Hye Seon ;
Cho, Kyu Ran ;
Seo, Bo Kyoung ;
Kang, Eun Young .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) :1943-1948
[29]   Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis [J].
Park, Sun-young ;
Kang, Bong Joo .
ULTRASONOGRAPHY, 2021, 40 (03) :318-332
[30]   Diagnostic performance of shear wave elastography in discriminating malignant and benign breast lesions Our experience with QelaXtoTM software [J].
Pesce, Karina ;
Binder, Fernando ;
Chico, Maria Jose ;
Swiecicki, Maria Paz ;
Galindo, Diana Herbas ;
Terrasa, Sergio .
JOURNAL OF ULTRASOUND, 2020, 23 (04) :575-583