Diagnostic performance of 2D-shear wave elastography in the diagnosis of breast cancer: a clinical appraisal of cutoff values

被引:15
作者
Bartolotta, Tommaso Vincenzo [1 ,2 ]
Orlando, Alessia Angela Maria [1 ]
Dimarco, Mariangela [2 ]
Zarcaro, Calogero [1 ]
Ferraro, Fabiola [1 ]
Cirino, Alessandra [1 ]
Matranga, Domenica [3 ]
Vieni, Salvatore [4 ]
Cabibi, Daniela [5 ]
机构
[1] Univ Hosp Policlin P Giaccone, Dept Biomed Neurosci & Adv Diagnost BiND, Via Vespro 129, I-90127 Palermo, Italy
[2] Fdn Ist G Giglio, Cefalu, PA, Italy
[3] Univ Hosp Policlin P Giaccone, Dept Hlth Promot & Mother & Child Care Internal M, Palermo, Italy
[4] Univ Hosp Policlin P Giaccone, Dept Surg Oncol & Oral Sci, Div Gen & Oncol Surg, Palermo, Italy
[5] Univ Hosp Policlin P Giaccone, Dept Hlth Promot Mother & Child Care Internal Med, Anat Pathol Unit, Palermo, Italy
来源
RADIOLOGIA MEDICA | 2022年 / 127卷 / 11期
关键词
Breast; Ultrasonography; Elasticity imaging techniques; Shear wave imaging; ULTRASOUND ELASTOGRAPHY; QUANTITATIVE PARAMETERS; DIFFERENTIAL-DIAGNOSIS; EFSUMB GUIDELINES; SHEAR; LESIONS; RECOMMENDATIONS; BENIGN; STRAIN; ULTRASONOGRAPHY;
D O I
10.1007/s11547-022-01546-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To assess the role of 2D-shear wave elastography (2D-SWE) in differentiating benign from malignant focal breast lesions (FBLs), providing new vendor-specific cutoff values. Methods 158 FBLs (size: 3.5-50 mm) detected in 151 women (age: 21-87 years) were prospectively evaluated by means 2D-SWE. For each lesion, an expert radiologist assessed US BI-RADS category and calculated the following four 2D-SWE parameters: (1) elasticity maximum (E-max); (2) mean elasticity (E-mean); (3) minimum elasticity (E-min); (4) elasticity ratio (E-ratio). US-guided core-biopsy was considered as standard of reference for all the FBLs classified as BI-RADS 4 or 5. For each 2D-SWE parameter, the optimal cutoff value for a diagnostic test was calculated using the Youden method. Diagnostic performance of the US BI-RADS and 2D-SWE parameters was calculated accordingly. Results 83/158 (52.5%) FBLs were benign and 75/158 (47.5%) were malignant. Statistically significant higher stiffness values were observed in malignant FBLs for all 2D-SWE parameters than in benign ones (p < 0.001). 2D-SWE cutoff values were 82.6 kPa, 66.0 kPa and 53.6 kPa, respectively, for E-max, E-mean, E-min and 330.8% for E-ratio. The 2D-SWE parameter showing the best diagnostic accuracy was E-max (85.44%). Considering US BI-RADS 3 (n = 60) and 4a (n = 32) FBLs, E-max and E-mean showed the best diagnostic accuracy (85.87% for both), without a statistically significant decrease in sensitivity (p = 0.7003 and p = 1, respectively). Conclusion Our study provides new vendor-specific cutoff values for 2D-SWE, suggesting its possible clinical use in the adjunctive assessment of category US-BI-RADS 3 and 4a breast masses.
引用
收藏
页码:1209 / 1220
页数:12
相关论文
共 41 条
  • [21] Shear Wave Elastography: Is It a Valuable Additive Method to Conventional Ultrasound for the Diagnosis of Small (≤2 cm) Breast Cancer?
    Kim, So Jung
    Ko, Kyung Hee
    Jung, Hae Kyoung
    Kim, Hyerin
    [J]. MEDICINE, 2015, 94 (42) : e1540
  • [22] Potential role of shear-wave ultrasound elastography for the differential diagnosis of breast non-mass lesions: preliminary report
    Ko, Kyung Hee
    Jung, Hae Kyoung
    Kim, So Joong
    Kim, Hyerin
    Yoon, Jung Hyun
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (02) : 305 - 311
  • [23] Krouskop T A, 1987, J Rehabil Res Dev, V24, P1
  • [24] Role of shear-wave elastography (SWE) in complex cystic and solid breast lesions in comparison with conventional ultrasound
    Lee, Bo Eun
    Chung, Jin
    Cha, Eun-Suk
    Lee, Jee Eun
    Kim, Jeoung Hyun
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1236 - 1241
  • [25] Combination of Quantitative Parameters of Shear Wave Elastography and Superb Microvascular Imaging to Evaluate Breast Masses
    Lee, Eun Ji
    Chang, Yun-Woo
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (09) : 1045 - 1054
  • [26] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Lee, Eun Jung
    Jung, Hae Kyoung
    Ko, Kyung Hee
    Lee, Jong Tae
    Yoon, Jung Hyun
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (07) : 1803 - 1811
  • [27] Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements
    Lee, Jihyuk
    Kang, Hyo-Jin
    Yoon, Jeong Hee
    Lee, Jeong Min
    [J]. ULTRASONOGRAPHY, 2021, 40 (02) : 217 - 227
  • [28] Diagnostic performance and color overlay pattern in shear wave elastography (SWE) for palpable breast mass
    Park, Jiyoon
    Woo, Ok Hee
    Shin, Hye Seon
    Cho, Kyu Ran
    Seo, Bo Kyoung
    Kang, Eun Young
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (10) : 1943 - 1948
  • [29] Combination of shear-wave elastography with ultrasonography for detection of breast cancer and reduction of unnecessary biopsies: a systematic review and meta-analysis
    Park, Sun-young
    Kang, Bong Joo
    [J]. ULTRASONOGRAPHY, 2021, 40 (03) : 318 - 332
  • [30] Diagnostic performance of shear wave elastography in discriminating malignant and benign breast lesions Our experience with QelaXtoTM software
    Pesce, Karina
    Binder, Fernando
    Chico, Maria Jose
    Swiecicki, Maria Paz
    Galindo, Diana Herbas
    Terrasa, Sergio
    [J]. JOURNAL OF ULTRASOUND, 2020, 23 (04) : 575 - 583