ELECTROCARDIOGRAPHIC CHANGES DURING CORONARY STENT PLACEMENT IN SWINE

被引:0
作者
Simeonova, Galina [1 ]
Dinev, D. [1 ]
Roydev, R. [1 ]
机构
[1] Trakia Univ, Fac Vet Med, Dept Vet Surg, Stara Zagora 6000, Bulgaria
来源
ACTA VETERINARIA-BEOGRAD | 2010年 / 60卷 / 5-6期
关键词
arrhythmia; coronary stents; ECG; swine; VENTRICULAR-FIBRILLATION; REDUCED INCIDENCE; BALLOON INJURY; CONTRAST-MEDIA; ANGIOGRAPHY; ANGIOPLASTY; CATHETER; ARTERY;
D O I
10.2298/AVB1006479S
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The ECG changes that occurred during coronary stent placement in healthy swine were investigated in order to clarify the effect of surgical manipulation on the electrical activity of the heart. The experiment was performed on nine female swine weighing 80+/-2.3 kg under halothane anaesthesia. Eighteen coronary stents were implanted into both left anterior and right coronary artery of the animals using a guiding catheter and transfemoral approach. Multi parameter patient monitor was used to examine closely the ECG changes during the procedure. Direct stent implantation was successful in 7 of 9 cases and these animals recovered uneventfully. The first two animals died 7-9 hours after surgery because of thrombosis of the stents. Initially all of the seven investigated animals showed sinus rhythm. During the procedure two of the animals developed ventricular arrhythmias. One type of seen electrocardiographic abnormalities was single ventricular premature complexes (VPCs) appearing with an irregular pattern. The other abnormality observed was bigeminia that was preceded by multiple VPCs. These ECG changes occurred when the tip of the catheter was advanced too deep through the aorta and touched the endocardium. ECG changes during coronary stent placement in healthy swine were closely related to the operative technique, but anesthetic agents may contribute to arrhythmias. 6F angiographic catheters did not cause coronary artery occlusion and myocardial ischemia in 80 kg pigs.
引用
收藏
页码:479 / 486
页数:8
相关论文
共 18 条
[1]   Influence of a nonionic, iso-osmolar contrast medium (iodixanol) versus an ionic, low-osmolar contrast medium (ioxaglate) on major adverse cardiac events in patients undergoing percutaneous transluminal coronary angioplasty a multicenter, randomized, double-blind study [J].
Bertrand, ME ;
Esplugas, E ;
Piessens, J ;
Rasch, W .
CIRCULATION, 2000, 101 (02) :131-136
[2]   COMPLICATION RATE OF CORONARY ARTERIOGRAPHY - REVIEW OF 5250 CASES STUDIED BY A PERCUTANEOUS FEMORAL TECHNIQUE [J].
BOURASSA, MG ;
NOBLE, J .
CIRCULATION, 1976, 53 (01) :106-114
[3]  
Chen J, 2008, REV ESP CARDIOL, V61, P1092
[4]  
Coelho Wilson Miguel Cecim, 2004, Arq Bras Cardiol, V83, P240
[5]  
Durst R, 2007, ISRAEL MED ASSOC J, V9, P290
[6]   EFFECTS OF CORONARY-ARTERY DISEASE ON THE VENTRICULAR-FIBRILLATION THRESHOLD IN MAN [J].
HOROWITZ, LN ;
SPEAR, JF ;
JOSEPHSON, ME ;
KASTOR, JA ;
MOORE, EN .
CIRCULATION, 1979, 60 (04) :792-797
[7]   Mechanisms of ventricular fibrillation during coronary angioplasty: increased incidence for the small orifice caliber of the right coronary artery [J].
Huang, JL ;
Ting, CT ;
Chen, YT ;
Chen, SA .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2002, 82 (03) :221-228
[8]   CORONARY INTIMAL PROLIFERATION AFTER BALLOON INJURY AND STENTING IN SWINE - AN ANIMAL-MODEL OF RESTENOSIS [J].
KARAS, SP ;
GRAVANIS, MB ;
SANTOIAN, EC ;
ROBINSON, KA ;
ANDERBERG, KA ;
KING, SB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) :467-474
[9]  
Kearns JB, 1969, J PHYSL P, p[51P, 53]
[10]   Aortic root catheter-directed coronary CT angiography in swine: Coronary enhancement with minimum volume of iodinated contrast material [J].
Kumar, Arun ;
Bis, Kostaki G. ;
Shetty, Anil ;
Vyas, Amit ;
Anderson, Andrew ;
Balasubramaniam, Mamtha ;
O'Neill, William ;
Stein, Wendy .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05) :W415-W422