Angular strain estimation method for elastography

被引:10
作者
Bae, Unmin [1 ,2 ]
Kim, Yongmin [1 ,2 ]
机构
[1] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
D O I
10.1109/TUFFC.2007.594
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the conventional cross-correlation-based strain estimation, there is a trade-off between the interpolation accuracy and the computational requirement. On the other hand, the autocorrelation-based method does not need interpolation, but it cannot estimate the wide range of displacements for elastography. We have developed a new strain estimator, called the angular strain estimation method, which does not need any interpolation and can estimate strain without restricting the range of displacements. The new method estimates strain utilizing complex correlation between correlated ultrasound signals from pre-and post-compression frames. From simulation and experiments, we found that the angular strain estimation method improves the accuracy and strain image quality compared to the conventional strain estimator using cross-correlation with interpolation. Furthermore, it is computationally efficient and can be readily incorporated in ultrasound machines for real-time elastography.
引用
收藏
页码:2653 / 2661
页数:9
相关论文
共 31 条
[1]   An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[2]   Real-time ultrasound elastography [J].
Bae, Unmin ;
Kim, Yongmin .
MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2007, 6513
[3]   Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro [J].
de Korte, CL ;
Pasterkamp, G ;
van der Steen, AFW ;
Woutman, HA ;
Bom, N .
CIRCULATION, 2000, 102 (06) :617-623
[4]   Triplex ultrasound: Elasticity imaging to age deep venous thrombosis [J].
Emelianov, SY ;
Chen, X ;
O'Donnell, M ;
Knipp, B ;
Myers, D ;
Wakefield, TW ;
Rubin, JM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (06) :757-767
[5]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[6]   Assessment of elastic parameters of human skin using dynamic elastography [J].
Gennisson, JL ;
Baldeweck, T ;
Tanter, M ;
Catheline, S ;
Fink, M ;
Sandrin, L ;
Cornillon, C ;
Querleux, B .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (08) :980-989
[7]   In vivo real-time freehand palpation imaging [J].
Hall, TJ ;
Zhu, YN ;
Spalding, CS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03) :427-435
[8]   Investigation of parametric spectral estimation techniques for elasticity imaging [J].
Hoyt, K ;
Forsberg, F ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (08) :1109-1121
[9]  
HUANG TS, 1995, ENVIRON GEOCHEM HLTH, V17, P1, DOI 10.1007/BF00188624
[10]   Three-dimensional tissue motion and its effect on image noise in elastography [J].
Kallel, F ;
Ophir, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1286-1296