Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 Å

被引:166
作者
Turonova, Beata [1 ]
Schur, Florian K. M. [1 ]
Wan, William [1 ]
Briggs, John A. G. [1 ,2 ]
机构
[1] European Mol Biol Lab, Struct & Computat Biol Unit, Meyerhofstr 1, Heidelberg, Germany
[2] MRC, Lab Mol Biol, Struct Studies Div, Francis Crick Ave, Cambridge, England
基金
欧洲研究理事会;
关键词
Cryo-electron microscopy; Tomography; Contrast transfer function; Subtomogram averaging; Defocus; Reconstruction; Weighted back projection; PARTICLE ELECTRON CRYOMICROSCOPY; CTF CORRECTION; 3-DIMENSIONAL STRUCTURE; IN-SITU; DEFOCUS; RECONSTRUCTION; MICROSCOPY; PROJECTIONS; MICROGRAPHS;
D O I
10.1016/j.jsb.2017.07.007
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Cryo-electron tomography (cryo-ET) allows cellular ultrastructures and macromolecular complexes to be imaged in three-dimensions in their native environments. Cryo-electron tomograms are reconstructed from projection images taken at defined tilt-angles. In order to recover high-resolution information from cryo-electron tomograms, it is necessary to measure and correct for the contrast transfer function (CTF) of the microscope. Most commonly, this is performed using protocols that approximate the sample as a two-dimensional (2D) plane. This approximation accounts for differences in defocus and therefore CTF across the tilted sample. It does not account for differences in defocus of objects at different heights within the sample; instead, a 3D approach is required. Currently available approaches for 3D-CTF correction are computationally expensive and have not been widely implemented. Here we simulate the benefits of 3D-CTF correction for high-resolution subtomogram averaging, and present a user-friendly, computationally-efficient 3D-CTF correction tool, NovaCTF, that is compatible with standard tomogram reconstruction workflows in IMOD. We validate the approach on synthetic data and test it using subtomogram averaging of real data. Consistent with our simulations, we find that 3D-CTF correction allows high-resolution structures to be obtained with much smaller subtomogram averaging datasets than are required using 2D-CTF. We also show that using equivalent dataset sizes, 3D-CTF correction can be used to obtain higher-resolution structures. We present a 3.4 angstrom resolution structure determined by subtomogram averaging.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 30 条
  • [1] SIMULTANEOUS ALGEBRAIC RECONSTRUCTION TECHNIQUE (SART) - A SUPERIOR IMPLEMENTATION OF THE ART ALGORITHM
    ANDERSEN, AH
    KAK, AC
    [J]. ULTRASONIC IMAGING, 1984, 6 (01) : 81 - 94
  • [2] [Anonymous], 1949, Extrapolation, interpolation, and smoothing of stationary time series: with engineering applications
  • [3] Advances in Single-Particle Electron Cryomicroscopy Structure Determination applied to Sub-tomogram Averaging
    Bharat, Tanmay A. M.
    Russo, Christopher J.
    Loewe, Jan
    Passmore, Lori A.
    Scheres, Sjors H. W.
    [J]. STRUCTURE, 2015, 23 (09) : 1743 - 1753
  • [4] INVERSION OF FAN-BEAM SCANS IN RADIO ASTRONOMY
    BRACEWELL, RN
    RIDDLE, AC
    [J]. ASTROPHYSICAL JOURNAL, 1967, 150 (2P1) : 427 - +
  • [5] Structural biology in situ - the potential of subtomogram averaging
    Briggs, John A. G.
    [J]. CURRENT OPINION IN STRUCTURAL BIOLOGY, 2013, 23 (02) : 261 - 267
  • [6] High-resolution noise substitution to measure overfitting and validate resolution in 3D structure determination by single particle electron cryomicroscopy
    Chen, Shaoxia
    McMullan, Greg
    Faruqi, Abdul R.
    Murshudov, Garib N.
    Short, Judith M.
    Scheres, Sjors H. W.
    Henderson, Richard
    [J]. ULTRAMICROSCOPY, 2013, 135 : 24 - 35
  • [7] Iterative reconstruction of cryo-electron tomograms using nonuniform fast Fourier transforms
    Chen, Yuxiang
    Foerster, Friedrich
    [J]. JOURNAL OF STRUCTURAL BIOLOGY, 2014, 185 (03) : 309 - 316
  • [8] RECONSTRUCTION OF 3 DIMENSIONAL STRUCTURE FROM PROJECTIONS AND ITS APPLICATION TO ELECTRON MICROSCOPY
    CROWTHER, RA
    DEROSIER, DJ
    KLUG, A
    [J]. PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1530): : 319 - &
  • [9] Restoration of weak phase-contrast images recorded with a high degree of defocus: The "twin image" problem associated with CTF correction
    Downing, Kenneth H.
    Glaeser, Robert M.
    [J]. ULTRAMICROSCOPY, 2008, 108 (09) : 921 - 928
  • [10] CTF determination and correction in electron cryotomography
    Fernandez, J. J.
    Li, S.
    Crowther, R. A.
    [J]. ULTRAMICROSCOPY, 2006, 106 (07) : 587 - 596