Ultrasound Biomicroscopy Comparison of Ab Interno and Ab Externo Intraocular Lens Scleral Fixation

被引:4
作者
Horiguchi, Lie [1 ]
Garcia, Patricia Novita [1 ,2 ]
Malavazzi, Gustavo Ricci [1 ,2 ]
Allemann, Norma [2 ]
Gomes, Rachel L. R. [2 ,3 ]
机构
[1] Irmandade Santa Casa Misericordia Sao Paulo, Dept Ophthalmol, Sao Paulo, SP, Brazil
[2] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, SP, Brazil
[3] Hosp Olhos Paulista, Rua Abilio Soares 218, BR-04005000 Sao Paulo, SP, Brazil
关键词
HAPTIC POSITION; SUTURE FIXATION; SULCUS;
D O I
10.1155/2016/9375091
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare ab interno and ab externo scleral fixation of posterior chamber intraocular lenses (PCIOL) using ultrasound biomicroscopy (UBM). Methods. Randomized patients underwent ab externo or ab interno scleral fixation of a PCIOL. Ultrasound biomicroscopy was performed 3 to 6 months postoperatively, to determine PCIOL centration, IOL distance to the iris at 12, 3, 6, and 9 hours, and haptics placement in relation to the ciliary sulcus. Results. Fifteen patients were enrolled in the study. The ab externo technique was used in 7 eyes (46.6%) and the ab interno in 8 eyes (53.3%). In the ab externo technique, 14 haptics were located: 4 (28.57%) in the ciliary sulcus; 2 (14.28%) anterior to the sulcus; and 8 (57.14%) posterior to the sulcus, 6 in the ciliary body and 2 posterior to the ciliary body. In the ab interno group, 4 haptics (25.0%) were in the ciliary sulcus, 2 (12.50%) anterior to the sulcus, and 10 (75.0%) posterior to the sulcus, 4 in the ciliary body and 6 posterior to the ciliary body. Conclusions. Ab externo and ab interno scleral fixation techniques presented similar results in haptic placement. Ab externo technique presented higher vertical tilt when compared to the ab interno.
引用
收藏
页数:5
相关论文
共 20 条
[1]  
Althaus C., 1993, Ophthalmologe, V90, P317
[2]   Long-term results of scleral fixation of posterior chamber intralocular lenses in children [J].
Asadi, Reza ;
Kheirkhah, Ahmad .
OPHTHALMOLOGY, 2008, 115 (01) :67-72
[3]   Scleral fixation of a single-piece multifocal intraocular lens [J].
Can, Ertugrul ;
Basaran, M. Resat ;
Gul, Adem .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (02) :249-251
[4]  
Cho Yong-Wun, 2014, Korean J Ophthalmol, V28, P181, DOI 10.3341/kjo.2014.28.2.181
[5]  
de Camargo Vianna Filho R., 2000, ARQ BRAS OFTALMOL, V63, P349
[6]   Sulcus Fixation of Foldable Intraocular Lenses Guided by Ultrasound Biomicroscopy [J].
Gao, Shasha ;
Qin, Tingyu ;
Wang, Shengnan ;
Lu, Yong .
JOURNAL OF OPHTHALMOLOGY, 2015, 2015
[7]   Intraocular lens tilt and decentration, anterior chamber depth, and refractive error after trans-scleral suture fixation surgery [J].
Hayashi, K ;
Hayashi, H ;
Nakao, F ;
Hayashi, F .
OPHTHALMOLOGY, 1999, 106 (05) :878-882
[8]   Ultrasound biomicroscopy comparison of ab interno and ab externo scleral fixation of posterior chamber intraocular lenses [J].
Kamal, Ahmed M. ;
Hanafy, Mervat ;
Ehsan, Asser ;
Tomerak, Reham H. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (05) :881-884
[9]   Posterior chamber intraocular lens implantation after capsular tear: Ultrasound biomicroscopy evaluation [J].
Loya, N ;
Lichter, H ;
Barash, D ;
Goldenberg-Cohen, N ;
Strassmann, E ;
Weinberger, D .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) :1423-1427
[10]   One-Haptic Fixation of Posterior Chamber Intraocular Lenses without Scleral Flaps [J].
Moawad, Ashraf I. ;
Ghanem, Asaad A. .
JOURNAL OF OPHTHALMOLOGY, 2012, 2012