Low temperature thermal radiative properties of gold coated metals

被引:9
作者
Frolec, Jiri [1 ]
Kralik, Tomas [1 ]
Srnka, Ales [1 ]
机构
[1] CAS, Inst Sci Instruments, Vvi, Kralovopolska 147, Brno 61264, Czech Republic
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2017年 / 82卷
关键词
Gold films; Heat transfer; Thermal radiation; Cryogenics; STAINLESS-STEEL; EMISSIVITY; SILVER; ABSORPTIVITY; SURFACES; NI; AU;
D O I
10.1016/j.ijrefrig.2017.06.034
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to assess the effect of gold deposition on thermal radiative properties of metallic materials, we measured total hemispherical emissivity and absorptivity of Au layers with a minimal thickness of 1 mu m in dependence on the temperature T-R of thermal radiation (from 20 K up to 320 K). Technically pure copper or titanium alloy (Ti-6Al-4V) was used as substrate while three types of Au layers were deposited by a sputtering process or a galvanic method. Emissivities among samples with Au layers ranged from 1.8% to 3.9% at room temperature. Galvanic deposition of pure Au lowered the original emissivity of Ti-6Al-4V alloy at 300 K from 15.8% to 3.4%, whereas the same deposition on mechanically polished Cu resulted in increase of emissivity by a factor of three, up to 3.2%. Absorptivity of each sample with Cu or Au surface was lower than its emissivity and showed a weaker dependence on T-R. (c) 2017 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 26 条
[1]  
Armaly B.F, 1970, J SPACECRAFT ROCKETS, V7, P1496
[2]   INFRARED REFLECTANCE AND EMITTANCE OF SILVER AND GOLD EVAPORATED IN ULTRAHIGH VACUUM [J].
BENNETT, JM ;
ASHLEY, EJ .
APPLIED OPTICS, 1965, 4 (02) :221-&
[3]  
Blaber M.G., 2010, GOLD SCI APPL, P13
[4]   CRYOGENIC FOURIER SPECTROMETER FOR MEASURING TRACE SPECIES IN THE LOWER STRATOSPHERE [J].
BRASUNAS, JC ;
KUNDE, VG ;
HERATH, LW .
APPLIED OPTICS, 1988, 27 (23) :4964-4976
[5]   A micromachined Joule-Thomson cryogenic cooler with parallel two-stage expansion [J].
Cao, H. S. ;
Vanapalli, S. ;
Holland, H. J. ;
Vermeer, C. H. ;
ter Brake, H. J. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 69 :223-231
[6]  
Daryabeigi K, 2006, THERMAL PROTECTION S, P1
[7]   Micromachined Joule-Thomson cold stages operating in the temperature range 80-250 K [J].
Derking, J. H. ;
Holland, H. J. ;
Lerou, P. P. P. M. ;
Tirolien, T. ;
ter Brake, H. J. M. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04) :1200-1207
[8]   Direct measurement of total emissivities at cryogenic temperatures: Application to satellite coatings [J].
Herve, P. ;
Rambure, N. ;
Sadou, A. ;
Ramel, D. ;
Francou, L. ;
Delouard, P. ;
Gavila, E. .
CRYOGENICS, 2008, 48 (11-12) :463-468
[9]  
Howell J.R., 2020, Thermal Radiation Heat Transfer
[10]   An application of Au thin-film emissivity barrier on Ni alloy [J].
Huang, Zhibin ;
Zhu, Dongmei ;
Lou, Fa ;
Zhou, Wancheng .
APPLIED SURFACE SCIENCE, 2008, 255 (05) :2619-2622