Development of a lactate biosensor based on conducting copolymer bound lactate oxidase

被引:91
|
作者
Suman, S
Singhal, R
Sharma, AL
Malthotra, BD
Pundir, CS [1 ]
机构
[1] Maharshi Dayanand Univ, Dept Biosci, Biochem Res Lab, Rohtak 124001, Haryana, India
[2] Natl Phys Lab, Biomol Elect & Conducting Polymer Res Grp, New Delhi 110012, India
关键词
lactate; lactate oxidase; immobilization; polyaniline-co-fluoroaniline; lactate biosensor; serum;
D O I
10.1016/j.snb.2004.12.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode was developed for determination of lactate in serum. To prepare this electrode, commercial lactate oxidase from Pediococcus species has been immobilized through glutaraldehyde coupling onto polyaniline-co-fluoroaniline film deposited on an Indium tin oxide (ITO) coated glass plate. This plate acted as working electrode when combined with Pt electrode as counter electrode to the electrometer for the development of a biosensor. The method is based on generation of electrons from H2O2 which is formed from lactic acid by immobilized lactate oxidase. The concentration of lactic acid is directly proportional to the current measured. The enzyme electrode showed optimum response when operated at 42 degrees C in 0.05 M, sodium phosphate buffer pH 6.5 for 50s, The biosensor showed a good performance with a linear response range from 0.1 to 5.5 mM/l. The minimum detection limit of the method is 0.1 mM/l and sensitivity of the sensor is 1.18 mu A/mM/l lactate. This electrode was employed for determination of lactate in serum. The serum values in healthy and diseased persons were in the range 0.51-2.9 and 5.0-15.0 mM. respectively. The analytical recovery of added lactic acid was 71%. Within batch and between batch CV were < 4 and < 5%. respectively. Among the various serum substances tested only 8-hydroxyquinoline, urea, ammonium molybdate and uric acid caused 64, 38, 34 and 31% inhibition, respectively. The electrode Was used 150 times over 26 days without any considerable loss of activity, when stored at 4 degrees C. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:768 / 772
页数:5
相关论文
共 50 条
  • [31] Development of long life lactate sensor using thermostable mutant lactate oxidase
    Minagawa, H
    Nakayama, N
    Matsumoto, T
    Ito, N
    BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4): : 313 - 318
  • [32] Fabrication of lactate biosensor based on lactate dehydrogenase immobilized on cerium oxide nanoparticles
    Nesakumar, Noel
    Sethuraman, Swaminathan
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2013, 410 : 158 - 164
  • [33] Sweat lactate biosensor based on lactate oxidase immobilized with flower-like NiCo2O4 and carbon nanotubes
    Tian, Liang
    Cai, Lei
    Ding, Zhengyuan
    Zhou, Yaqiu
    Zhang, Yan
    Liu, Quan
    Ge, Xin
    Yu, Chunmei
    MICROCHEMICAL JOURNAL, 2024, 200
  • [34] Determination of lactate by the intrinsic fluorescence of lactate oxidase
    Galban, J.
    De Marcos, S.
    Segura, P.
    Castillo, J. R.
    Naturwissenschaften, 829
  • [35] A protein biosensor for lactate
    D'Auria, S
    Gryczynski, Z
    Gryczynski, I
    Rossi, M
    Lakowicz, JR
    ANALYTICAL BIOCHEMISTRY, 2000, 283 (01) : 83 - 88
  • [36] DETERMINATION OF LACTATE BY THE INTRINSIC FLUORESCENCE OF LACTATE OXIDASE
    GALBAN, J
    DEMARCOS, S
    SEGURA, P
    CASTILLO, JR
    ANALYTICA CHIMICA ACTA, 1994, 299 (02) : 277 - 284
  • [37] A novel Lactate biosensor
    Tong Jijun
    Hu Jie
    Huang Zhongchao
    Pan Min
    Chen Yuquan
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 252 - 254
  • [38] Dehydrogenase-based biosensor for lactate.
    Kelly, RS
    Dalton, SL
    Fitzpatrick, MK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 211 : 312 - CHED
  • [39] Characterization of Lactate Sensors Based on Lactate Oxidase and Palladium Benzoporphyrin Immobilized in Hydrogels
    Andrus, Liam P.
    Unruh, Rachel
    Wisniewski, Natalie A.
    McShane, Michael J.
    BIOSENSORS-BASEL, 2015, 5 (03): : 398 - 416
  • [40] A conducting salt-based amperometric biosensor for measurement of extracellular lactate accumulation in ischemic myocardium
    Marzouk, SAM
    Cosofret, VV
    Buck, RP
    Yang, H
    Cascio, WE
    Hassan, SSM