Modeling of Pollutants Removal in Subsurface Vertical Flow and Horizontal Flow Constructed Wetlands

被引:20
作者
Dabrowski, Wojciech [1 ]
Karolinczak, Beata [2 ]
Malinowski, Pawel [1 ]
Boruszko, Dariusz [1 ]
机构
[1] Bialystok Tech Univ, Fac Civil & Environm Engn, 45E Wiejska St, PL-15351 Bialystok, Poland
[2] Warsaw Univ Technol, Fac Bldg Serv Hydro & Environm Engn, Nowowiejska 20, PL-00653 Warsaw, Poland
关键词
P-k-C* model; subsurface vertical flow constructed wetlands; subsurface horizontal flow constructed wetlands; reject water; treatment modeling; dairy wastewater treatment plant; anaerobic sewage sludge digestion; WASTE-WATER; SBR; NITRITATION; REJECT;
D O I
10.3390/w11010180
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Reject water is a by-product of every municipal and agro-industrial wastewater treatment plant (WWTP) applying sewage sludge stabilization. It is usually returned without pre-treatment to the biological part of WWTP, having a negative impact on the nitrogen removal process. The current models of pollutants removal in constructed wetlands concern municipal and industrial wastewater, whereas there is no such model for reject water. In the presented study, the results of treatment of reject water from dairy WWTP in subsurface vertical flow (SS VF) and subsurface horizontal flow (SS HF) beds were presented. During a one-year research period, SS VF bed reached 50.7% efficiency of TN removal and 73.8% of NH4+-N, while SS HF bed effectiveness was at 41.4% and 62.0%, respectively. In the case of BOD5 (biochemical oxygen demand), COD (chemical oxygen demand), NH4+-N, and TN (total nitrogen), the P-k-C* model was applied. Multi-model nonlinear segmented regression analysis was performed. Final mathematical models with estimates of parameters determining the treatment effectiveness were obtained. Treatment efficiency increased up to the specific temperature, then it was constant. The results obtained in this work suggest that it may be possible to describe pollutant removal behavior using simplified models. In the case of TP (total phosphorus) removal, distribution tests along with a t-test were performed. All models predict better treatment efficiency in SS VF bed, except for TP.
引用
收藏
页数:17
相关论文
共 38 条
[1]   NEW LOOK AT STATISTICAL-MODEL IDENTIFICATION [J].
AKAIKE, H .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1974, AC19 (06) :716-723
[2]  
American Public Health Association (APHA), 2005, 2005 STAND METH EX W
[3]  
[Anonymous], 1998, Model Selection and Multimodel Inference: A Practical Information-theoretic Approach
[4]  
[Anonymous], ANN SET ENV PROT
[5]  
[Anonymous], 2017, AICCMODAVG MODEL SEL
[6]  
Baty F, 2015, J STAT SOFTW, V66, P1
[7]   IMPACT OF EFFECTIVE MICROORGANISMS BACTERIA ON LOW-INPUT SEWAGE SLUDGE TREATMENT [J].
Boruszko, Dariusz ;
Butarewicz, Andrzej .
ENVIRONMENT PROTECTION ENGINEERING, 2015, 41 (04) :83-96
[8]   Constructed Wetlands for Water Treatment: New Developments [J].
Carvalho, Pedro N. ;
Arias, Carlos A. ;
Brix, Hans .
WATER, 2017, 9 (06)
[9]   Nitrogen Removal in a Horizontal Subsurface Flow Constructed Wetland Estimated Using the First-Order Kinetic Model [J].
Cui, Lijuan ;
Li, Wei ;
Zhang, Yaqiong ;
Wei, Jiaming ;
Lei, Yinru ;
Zhang, Manyin ;
Pan, Xu ;
Zhao, Xinsheng ;
Li, Kai ;
Ma, Wu .
WATER, 2016, 8 (11)