摘要
Introduction Negative component abolition of the unipolar signal (unipolar signal modification [USM]) reflects the lesion transmurality. The purpose of this study was to compare the procedural safety and outcome between high-power and conventional-power atrial radiofrequency applications during a pulmonary vein isolation (PVI) using USM as a local endpoint. Methods and Results High-power (50 W) and conventional-power (25-40 W) applications were compared among 120 consecutive patients with paroxysmal atrial fibrillation who underwent a USM-guided PVI. The first 60 patients were treated with conventional-power (CP) group and last 60 with high-power (HP) group. The atrial radiofrequency applications lasted for 5 to 10 seconds (CP group) or 3 to 5 seconds (HP group) after the USM. All procedures were performed using 3D mapping systems with image integration and esophageal temperature monitoring. The baseline characteristics were similar between the two groups. The HP group had fewer acute PV reconnections (62% vs 78%; P = .046) and a reduced procedure time (119.3 +/- 28.1 vs 140.1 +/- 51.2 minutes; P = .04). Freedom from recurrence after a single ablation procedure without any antiarrhythmic drugs was higher in the HP group than CP group (88.3% vs 73.3% at 12-months after the procedure, log-rank; P = .0423). There were no major complications that required any intervention. Conclusions The high-power PVI guided by USM decreased the procedural time and may improve the procedural outcomes without compromising the safety.
引用
收藏
页码:1702 / 1708
页数:7
相关论文
共 25 条
  • [1] Role of Contact Force Sensing in Catheter Ablation of Cardiac Arrhythmias Evolution or History Repeating Itself?
    Ariyarathna, Nilshan
    Kumar, Saurabh
    Thomas, Stuart P.
    Stevenson, William G.
    Michaud, Gregory F.
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (06) : 707 - 723
  • [2] High-Power Radiofrequency Catheter Ablation of Atrial Fibrillation Using Late Gadolinium Enhancement Magnetic Resonance Imaging as a Novel Index of Esophageal Injury
    Baher, Alex
    Kheirkhahan, Mobin
    Rechenmacher, Stephen J.
    Marashly, Qussay
    Kholmovski, Eugene G.
    Siebermair, Johannes
    Acharya, Madan
    Aljuaid, Mossab
    Morris, Alan K.
    Kaur, Gagandeep
    Han, Frederick T.
    Wilson, Brent D.
    Steinberg, Benjamin A.
    Marrouche, Nassir F.
    Chelu, Mihail G.
    [J]. JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (12) : 1583 - 1594
  • [3] High-power and short-duration ablation for pulmonary vein isolation: Safety, efficacy, and long-term durability
    Barkagan, Michael
    Contreras-Valdes, Fernando M.
    Leshem, Eran
    Buxton, Alfred E.
    Nakagawa, Hiroshi
    Anter, Elad
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (09) : 1287 - 1296
  • [4] Pulmonary vein isolation using a higher power shorter duration CLOSE protocol with a surround flow ablation catheter
    Berte, Benjamin
    Hilfiker, Gabi
    Russi, Ian
    Moccetti, Federico
    Cuculi, Florim
    Toggweiler, Stefan
    Ruschitzka, Frank
    Kobza, Richard
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (11) : 2199 - 2204
  • [5] Elimination of the negative component of the unipolar electrogram as a local procedural endpoint during paroxysmal atrial fibrillation catheter ablation using contact-force sensing: the UNIFORCE study
    Bortone, Agustin
    Lagrange, Philippe
    Cauchemez, Bruno
    Durand, Cyril
    Dieuzaide, Pierre
    Prevot, Sebastien
    Mechulan, Alexis
    Pambrun, Thomas
    Martin, Ruairidh
    Parlier, Pauline
    Masse, Alexandre
    Marijon, Eloi
    Albenque, Jean-Paul
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2017, 49 (03) : 299 - 306
  • [6] Elimination of the Negative Component of the Unipolar Atrial Electrogram as an In Vivo Marker of Transmural Lesion Creation Acute Study in Canines
    Bortone, Agustin
    Brault-Noble, Guillaume
    Appetiti, Anthony
    Marijon, Eloi
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (04) : 905 - 911
  • [7] Unipolar Signal Modification as a Guide for Lesion Creation During Radiofrequency Application in the Left Atrium Prospective Study in Humans in the Setting of Paroxysmal Atrial Fibrillation Catheter Ablation
    Bortone, Agustin
    Appetiti, Anthony
    Bouzeman, Abdeslam
    Maupas, Eric
    Ciobotaru, Vlad
    Boulenc, Jean-Marc
    Pujadas-Berthault, Penelope
    Rioux, Philippe
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) : 1095 - 1102
  • [8] High-power short-duration versus standard radiofrequency ablation: Insights on lesion metrics
    Bourier, Felix
    Duchateau, Josselin
    Vlachos, Konstantinos
    Lam, Anna
    Martin, Claire A.
    Takigawa, Masateru
    Kitamura, Takeshi
    Frontera, Antonio
    Cheniti, Ghassen
    Pambrun, Thomas
    Klotz, Nicolas
    Denis, Arnaud
    Derval, Nicolas
    Cochet, Hubert
    Sacher, Frederic
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (11) : 1570 - 1575
  • [9] Long-term outcomes after low power, slower movement versus high power, faster movement irrigated-tip catheter ablation for atrial fibrillation
    Bunch, T. Jared
    May, Heidi T.
    Bair, Tami L.
    Crandall, Brian G.
    Cutler, Michael J.
    Mallender, Charles
    Weiss, J. Peter
    Osborn, Jeffrey S.
    Day, John D.
    [J]. HEART RHYTHM, 2020, 17 (02) : 184 - 189
  • [10] Calkins H, 2017, HEART RHYTHM, V14, pE445, DOI [10.1093/europace/eux275, 10.1016/j.hrthm.2017.07.009, 10.1016/j.hrthm.2017.05.012]