Energy-Optimal Structures of HVAC System for Cleanrooms as a Function of Key Constant Parameters and External Climate

被引:0
作者
Porowski, Mieczyslaw [1 ]
Jakubiak, Monika [1 ]
机构
[1] Poznan Univ Tech, Inst Environm Engn & Bldg Installat, Pl M Sklodowskiej Curie 5, PL-60965 Poznan, Poland
关键词
cleanrooms; ventilation; air conditioning; energy consumption; optimization; HOLISTIC PERSPECTIVE; SEMICONDUCTOR; OPTIMIZATION; PERFORMANCE; CONSUMPTION; IMPROVEMENT; ROOMS;
D O I
10.3390/en15010313
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article presents approximating relations defining energy-optimal structures of the HVAC (Heating, Ventilation, Air Conditioning) system for cleanrooms as a function of key constant parameters and energy-optimal control algorithms for various options of heat recovery and external climates. The annual unit primary energy demand of the HVAC system for thermodynamic air treatment was adopted as the objective function. Research was performed for wide representative variability ranges of key constant parameters: cleanliness class-C-s (ISO5 & DIVIDE;ISO8), unit cooling loads-q(j) (100 & DIVIDE; 500) W/m(2) and percentage of outdoor air-alpha(o) (5 & DIVIDE; 100)%. HVAC systems are described with vectors x over bar with coordinates defined by constant parameters and decision variables, and the results are presented in the form of approximating functions illustrating zones of energy-optimal structures of the HVAC system x over bar * = f (C-s, q(j), alpha(o)). In the optimization procedure, the type of heat recovery as an element of optimal structures of the HVAC system and algorithms of energy-optimal control were defined based on an objective function and simulation models. It was proven that using heat recovery is profitable only for HVAC systems without recirculation and with internal recirculation (savings of 5 & DIVIDE; 66%, depending on the type of heat recovery and the climate), while it is not profitable (or generates losses) for HVAC systems with external recirculation or external and internal recirculation at the same time.
引用
收藏
页数:41
相关论文
共 43 条
  • [1] ASHRAE, 2011, ASHRAE APPL HDB
  • [2] Various Energy-Saving Approaches to a TFT-LCD Panel Fab
    Chang, Cheng-Kuang
    Lin, Tee
    Hu, Shih-Cheng
    Fu, Ben-Ran
    Hsu, Jung-Sheng
    [J]. SUSTAINABILITY, 2016, 8 (09):
  • [3] Using the Koppen classification to quantify climate variation and change: An example for 1901-2010
    Chen, Deliang
    Chen, Hans Weiteng
    [J]. ENVIRONMENTAL DEVELOPMENT, 2013, 6 : 69 - 79
  • [4] Chen J, 2009, ASHRAE TRAN, V115, P299
  • [5] DIN, 19464201809 DIN
  • [6] Suitability evaluation on laminar airflow and mixing airflow distribution strategies in operating rooms: A case study at St. Olavs Hospital
    Fan, Minchao
    Cao, Guangyu
    Pedersen, Christoffer
    Lu, Shilei
    Stenstad, Liv-Inger
    Skogas, Jan Gunnar
    [J]. BUILDING AND ENVIRONMENT, 2021, 194
  • [7] Power consumption of semiconductor fabs in Taiwan
    Hu, SC
    Chuah, YK
    [J]. ENERGY, 2003, 28 (08) : 895 - 907
  • [8] A comparative study on energy consumption for HVAC systems of high-tech FABs
    Hu, Shih-Cheng
    Tsao, Jhy-Ming
    [J]. APPLIED THERMAL ENGINEERING, 2007, 27 (17-18) : 2758 - 2766
  • [9] Analysis of energy efficiency improvement of high-tech fabrication plants
    Hu, Shih-Cheng
    Lin, Tee
    Fu, Ben-Ran
    Chang, Cheng-Kung
    Cheng, I-Yun
    [J]. INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (04) : 508 - 515
  • [10] Energy savings approaches for high-tech manufacturing factories
    Hu, Shih-Cheng
    Lin, Tee
    Huang, Shao-Huan
    Fu, Ben-Ran
    Hu, Ming-Hsuan
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2020, 17