Line outage detection using optimal number of Phasor Measurement Unit

被引:1
|
作者
Kumar, Hemant [1 ]
Dahiya, Ratna [1 ]
机构
[1] NIT Kurukshetra, Elect Engn Dept, Kurukshetra, Haryana, India
关键词
Phasor Measurement unit (PMU); line outage; SCADA; voltage angle; Impedance angle;
D O I
10.1109/i-pact44901.2019.8960027
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
The power distribution network needs to be monitored in an effective manner against the line outages. Phasor Measurement Unit (PMU) is a device which is used to estimate the magnitude and phase angle of an electrical phasor quantity. PMUs are distributed globally to provide time synchronized information to operators through phasor data concentrator. In this paper, a new algorithm to identify single line outage using the PMU has been proposed. The voltage phasor angles are taken only at buses where the PMUs are located. Further the optimal location of PMUs is identified by an algorithm based on maximum connectivity of buses. Proposed algorithm is developed in MATLAB environment and tested on IEEE 9 bus system which is simulated in PSAT software.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Maiden application of rank correlation coefficient for line outage detection using current phasor ofPMUs
    Alam, Mehebub
    Kundu, Shubhrajyoti
    Thakur, Siddhartha Sankar
    Banerjee, Sumit
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (10):
  • [22] Implementation of a Phasor Measurement Unit using LabVIEW
    Krishnan, Anaga
    Jain, Akshay Kumar
    Centeno, Virgilio A.
    2018 CLEMSON UNIVERSITY POWER SYSTEMS CONFERENCE (PSC), 2018,
  • [23] Optimal Placement of Phasor Measurement Unit for Observation Reliability Enhancement
    Van-Khoi Tran
    Zhang, He-sheng
    Van-Nghia Nguyen
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2017, 12 (03) : 996 - 1006
  • [24] Optimal Phasor Measurement Unit Placement by an Improved PSO Algorithm
    Wang, Jian-ming
    Li Chuandong
    Zhang, Jian
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [25] PSO Based Optimal Phasor Measurement Unit Placement Considering Measurement Redundancy
    Subbaiyan, Thangavel
    Venkatachalam, Yuvaraju
    2020 3RD INTERNATIONAL CONFERENCE ON ENERGY, POWER AND ENVIRONMENT: TOWARDS CLEAN ENERGY TECHNOLOGIES (ICEPE 2020), 2021,
  • [26] Simulation of Wide Area Measurement System with Optimal Phasor Measurement Unit Location
    Das, Soumik
    Ghosh, Debomita
    Ghose, T.
    Mohanta, D. K.
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 226 - 230
  • [27] Optimal placement of Phasor measurement unit in power system using meta-heuristic algorithms
    Kouzou, Ahmed Lakhdar
    Bentarzi, Hamid
    Mohammedi, Ridha Djamal
    Laoumer, Mosbah
    EEA - Electrotehnica, Electronica, Automatica, 2019, 67 (02): : 98 - 113
  • [28] Simulation of Phasor Measurement Unit (PMU) Using Labview
    Mondal, Sourav
    Murthy, Ch
    Roy, D. S.
    Mohanta, D. K.
    2014 14TH INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING (EEEIC), 2014, : 164 - 168
  • [29] Optimal Placement of Phasor Measurement Unit System on the Hungarian Transmission Network
    Galo, Andras
    Farkas, Csaba
    Gregus, Zoltan
    9TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY, IYCE 2024, 2024,
  • [30] Phasor Measurement Unit using GPRS Wireless Connectivity
    Zambrano, Alvaro A.
    Leon, Miguel A.
    Rivas, Edwin
    2011 IEEE PES CONFERENCE ON INNOVATIVE SMART GRID TECHNOLOGIES LATIN AMERICA (ISGT LA), 2011,