The power distribution network needs to be monitored in an effective manner against the line outages. Phasor Measurement Unit (PMU) is a device which is used to estimate the magnitude and phase angle of an electrical phasor quantity. PMUs are distributed globally to provide time synchronized information to operators through phasor data concentrator. In this paper, a new algorithm to identify single line outage using the PMU has been proposed. The voltage phasor angles are taken only at buses where the PMUs are located. Further the optimal location of PMUs is identified by an algorithm based on maximum connectivity of buses. Proposed algorithm is developed in MATLAB environment and tested on IEEE 9 bus system which is simulated in PSAT software.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Line Outage Detection Using Phasor Measurement Units
    Srikumar, M. S.
    Ananthapadmanbha, T.
    Khan, Faraz Zafar
    Girish, V
    SMART GRID TECHNOLOGIES (ICSGT- 2015), 2015, 21 : 88 - 95
  • [2] Line outage identification based on partial measurement of Phasor Measurement Unit (PMU)
    Guo, Jingyuan
    Yang, Tao
    Feng, Hui
    Hu, Bo
    SIGNAL AND INFORMATION PROCESSING, NETWORKING AND COMPUTERS, 2016, : 175 - 184
  • [3] Effects of Phasor Measurement Uncertainty on Power Line Outage Detection
    Chen, Chen
    Wang, Jianhui
    Zhu, Hao
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2014, 8 (06) : 1127 - 1139
  • [4] Line Outage Detection Using Phasor Angle Measurements
    Tate, Joseph Euzebe
    Overbye, Thomas J.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (04) : 1644 - 1652
  • [5] Double Line Outage Detection Using Phasor Angle Measurements
    Tate, Joseph Euzebe
    Overbye, Thomas J.
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 3277 - +
  • [6] External System Line Outage Identification Using Phasor Measurement Units
    Emami, Roozbeh
    Abur, Ali
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) : 1035 - 1040
  • [7] Line Outage Localization Using Phasor Measurement Data in Transient State
    Garcia, Manuel
    Catanach, Thomas
    Wiel, Scott Vander
    Bent, Russell
    Lawrence, Earl
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (04) : 3019 - 3027
  • [8] Optimal phasor measurement unit placement using genetic algorithms
    Marín, FJ
    García-Lagos, F
    Joya, G
    Sandoval, F
    COMPUTATIONAL METHODS IN NEURAL MODELING, PT 1, 2003, 2686 : 486 - 493
  • [9] Line Outage Detection Using Support Vector Machine (SVM) Based on the Phasor Measurement Units (PMUs) Technology
    Abdelaziz, A. Y.
    Mekhamer, S. F.
    Ezzat, M.
    El-Saadany, E. F.
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [10] PMU based line outage identification using comparison of current phasor measurement technique
    Alam, Mehebub
    Kundu, Shubhrajyoti
    Thakur, Siddhartha Sankar
    Banerjee, Sumit
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 115