Use of 6-mm Short Implants in Japanese Patients: Clinical, Radiologic, and Patient Satisfaction Results in a Retrospective Study with a 2-Year Follow-up

被引:3
|
作者
Takeshita, Kenji [1 ,2 ]
Naito, Yoshihito [3 ]
Kitamura, Tomohisa [4 ]
Funaki, Katsuyuki [5 ]
Toia, Marco [6 ]
Stocchero, Michele [6 ]
Taninokuchi, Hiromi [7 ]
Morishima, Hiromitsu [2 ]
Takahashi, Tetsu [2 ]
机构
[1] Takeshita Dent Clin Success Implant Ctr, Tokyo, Japan
[2] Tohoku Univ, Grad Sch Dent Med, Div Oral & Maxillofacial Surg, Sendai, Miyagi, Japan
[3] Sweden Dent Clin Kokufu, Kokufu, Tokushima, Japan
[4] Saitama Med Univ Hosp, Dept Oral & Maxillofacial Surg, Saitama, Japan
[5] Hoya Dent & Oral Surg Clin, Tokyo, Japan
[6] Malmo Univ, Fac Odontol, Dept Oral & Maxillofacial Surg & Oral Med, Malmo, Sweden
[7] Tokyo Med & Dent Univ, Dept Oral Implantol & Regenerat Dent Med, Tokyo, Japan
关键词
DENTAL IMPLANTS; MAXILLA; OUTCOMES; SURFACE; MM;
D O I
10.11607/prd.5086
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Implant therapy for tooth loss in the molar area is challenging due to the anatomical limitations, requiring bone augmentation procedures that are associated with high surgical complexity and long postsurgical recovery. Recently, many studies have demonstrated the usefulness of short implants. However, few studies have been performed in Japanese patients to evaluate peri-implant bone changes, changes in peri-implant epithelial tissue, and patient satisfaction. The present study included 16 patients (5 men, 11 women; mean age: 60 years) who received 26 short (6-mm) implants. Changes in peri-implant bone and epithelial tissue were measured radiographically at superstructure loading and after 2 years. Peri-implant pocket probing depth was measured at the epithelial tissue and compared at both time points. Patient satisfaction was graded using the Oral Health Impact Profile (OHIP-14) before treatment and at follow-up. The mean mesial and distal bone levels were -0.05 mm and 0.37 mm at loading, respectively, and were 0.33 mm and 0.53 mm after 2 years, respectively. Significant peri-implant bone formation for mesial and distal bone levels at both time points were determined by Wilcoxon signed-rank test. Mean probing depth increased slightly, from 3.03 mm at loading to 3.33 mm after 2 years, but no significant difference was found. The OHIP-14 found that patient satisfaction levels increased after 2 years. Using 6-mm short implants in sites with insufficient bone levels can be a highly beneficial treatment option for patients, as it avoids the need for bone augmentation. However, more long-term and detailed studies on the clinical outcomes for these implants are required. Int J Periodontics Restorative Dent 2022;42:205-213. doi: 10.11607/prd.5086
引用
收藏
页码:205 / +
页数:13
相关论文
共 50 条
  • [1] Implant Survival Rate and Marginal Bone Loss of 6-mm Short Implants: A 2-Year Clinical Report
    Bratu, Emanuel
    Chan, Hsun-Liang
    Mihali, Sorin
    Karancsi, Olimpiu
    Bratu, Dana Cristina
    Fu, Jia-Hui
    Wang, Hom-Lay
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : 1425 - 1428
  • [2] Retrospective Multicenter Study of 230 6-mm SLA-Surfaced Implants with 1- to 6-Year Follow-Up
    Rodrigo, Daniel
    Cabello, Gustavo
    Herrero, Mariano
    Gonzalez, David
    Herrero, Federico
    Aracil, Luis
    Morante, Sergio
    Rebelo, Helena
    Villaverde, Gabriel
    Garcia, Andres
    Alonso, Angel
    Barrachina, Manuel
    Blanco, Juan
    Almeida, Ricardo Faria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (05) : 1331 - 1337
  • [3] A prospective, multicentre study of 6-mm short implants in posterior alveolar bone supporting splinted crowns: A 5-year follow-up study
    Sui, Huiping
    Tang, Zhihui
    Zhang, Xiao
    Wei, Diyuan
    Meng, Huanxin
    Han, Jie
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2022, 49 (06) : 537 - 546
  • [4] Clinical Assessment of Short (> 6 mm and ≤ 8.5 mm) Implants in Posterior Sites with an Average Follow-Up of 74 Months: A Retrospective Study
    de Oliveira Fernandes, Gustavo Vicentis
    Neves Ferreira, Newton da Rocha
    Heboyan, Artak
    Nassani, Leonardo Mohamad
    Afonso Pereira, Rafael Martins
    Hasse Fernandes, Juliana Campos
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2023, 38 (05) : 915 - +
  • [5] Short (6-mm) dental implants versus sinus floor elevation and placement of longer (10-mm) dental implants: a randomized controlled trial with a 3-year follow-up
    Bechara, Souheil
    Kubilius, Ricardas
    Veronesi, Giovanni
    Pires, Jefferson T.
    Shibli, Jamil A.
    Mangano, Francesco G.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (09) : 1097 - 1107
  • [6] Results at the 1-Year Follow-Up of a Prospective Cohort Study with Short, Zirconia Implants
    Balmer, Marc
    Fischer, Carolin
    Pirc, Miha
    Hammerle, Christoph H. F.
    Jung, Ronald E.
    MATERIALS, 2022, 15 (16)
  • [7] Flapless implant surgery: a 2-year follow-up study of 40 implants
    Sunitha, Raja V.
    Sapthagiri, Enukurthi
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (04): : E237 - E243
  • [8] Short implants in the severely resorbed maxilla: A 2-year retrospective clinical study
    Renouard, F
    Nisand, D
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 : S104 - S110
  • [9] Dental Implants with Different Neck Design: A Prospective Clinical Comparative Study with 2-Year Follow-Up
    Montemezzi, Pietro
    Ferrini, Francesco
    Pantaleo, Giuseppe
    Gherlone, Enrico
    Cappare, Paolo
    MATERIALS, 2020, 13 (05)
  • [10] Osseointegrated implants in a patient with Papillon-Lefevre syndrome -: A 41/2-year follow-up
    Ullbro, C
    Crossner, CG
    Lundgren, T
    Stålblad, PÅ
    Renvert, S
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2000, 27 (12) : 951 - 954