Construction and test of the precision drift chambers for the ATLAS muon spectrometer

被引:10
作者
Bauer, F [1 ]
Blum, W
Bratzler, U
Dietl, H
Kotov, S
Kroha, H
Lagouri, T
Manz, A
Ostapchuk, A
Richter, R
Schael, S
Chouridou, S
Deile, M
Kortner, O
Staude, A
Ströhmer, R
Trefzger, T
机构
[1] CEA Saclay, F-91191 Gif Sur Yvette, France
[2] Max Planck Inst Phys & Astrophys, D-80805 Munich, Germany
[3] Univ Munich, D-80799 Munich, Germany
[4] Joint Inst Nucl Res, Dubna 141980, Moscow Region, Russia
关键词
ATLAS detector; drift chambers; drift tubes; muon spectrometer;
D O I
10.1109/23.940070
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The Monitored drift tube (MDT) chambers for the union spectrometer of the ATLAS detector at the large hadron collider (LHC) consist of three or four layers of pressurised drift tub es on either side of a space frame carrying an optical deformation monitoring system. The chambers have to provide a track position resolution of 40 mum with a single-tube resolution of at least 80 mum and a sense wire positioning accuracy of 20 mum (rms). The feasibility was demonstrated with the full-scale prototype of one of the largest MDT chambers with 432 drift tubes of 3.8 in length. For the ATLAS union spectrometer, 88 chambers of this type have to be built. The first chamber has been completed with a mire positioning accuracy of 14 mum (rms).
引用
收藏
页码:302 / 307
页数:6
相关论文
共 6 条
[1]  
AIRAPETIAN A, 1997, CERNLHCC9722
[2]   High-precision X-ray tomograph for quality control of the ATLAS muon monitored drift chambers [J].
Berbiers, J ;
Drakoulakos, D ;
Fabjan, CW ;
Grau, S ;
Gschwendtner, E ;
Maugain, JM ;
Rangod, S ;
Rohrbach, F ;
Sbrissa, E ;
Sedykh, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 419 (2-3) :342-350
[3]   A novel laser-alignment system for tracking detectors using transparent silicon strip sensors [J].
Blum, W ;
Kroha, H ;
Widmann, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1194-1199
[4]   A novel laser alignment system for tracking detectors using transparent silicon strip sensors [J].
Blum, W ;
Kroha, H ;
Widmann, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :413-417
[5]  
BLUM W, 1996, NUCL INSTRUM METHODS, V377, pA404
[6]  