Chemiluminescent determination of cholesterol by flow injection analysis with immobilized cholesterol oxidase.

被引:0
作者
Nabi, A
Rashid, A
Yaqoob, M
机构
关键词
chemiluminescence; cholesterol oxidase; immobilized enzyme; flow-injection; cholesterol;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive chemiluminescent assay for the determination of cholesterol in blood serum is described. The procedure is based on the measurement of chemiluminescence emission resulting from the oxidation of Luminol with hydrogen peroxide in the presence of catalyst, cobalt(II). Hydrogen peroxide was produced by passing cholesterol samples through an immobilized cholesterol oxidase column. The limit of detection was 0.01 mg/dl and the relative standard deviation over the range of 10-60 mg/dl was less than 5%. Results agreed well with those obtained with a spectrophotometric method for the determination of cholesterol in serum.
引用
收藏
页码:2281 / 2288
页数:8