Newborn tissue concentrations of bupivacaine following maternal epidural administration during labor in guinea pigs

被引:3
|
作者
Golub, MS [1 ]
Kaaekuahiwi, MA
Eisele, PH
Zhang, HJ
Jones, AD
Eisele, JH
机构
[1] Univ Calif Davis, Calif Reg Primate Res Ctr, Davis, CA 95616 USA
[2] Univ Calif Davis, Sch Vet Med, Anim Resources Serv, Davis, CA 95616 USA
[3] Univ Calif Davis, Sch Med, Dept Anesthesiol, Davis, CA 95616 USA
[4] Univ Calif Davis, Facil Adv Instrumentat, Davis, CA 95616 USA
来源
BIOLOGY OF THE NEONATE | 1998年 / 74卷 / 04期
关键词
bupivacaine; obstetric anesthesia; pharmacokinetics; epidural bupivacaine; guinea pig; newborn; brain; heart; liver; plasma;
D O I
10.1159/000014038
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Newborn plasma concentrations of maternally administered bupivacaine are often measured, but it is unclear how well they reflect tissue concentrations. Bupivacaine (0.25%) was administered epidurally (0.12 ml/kg) 10 min prior to labor induction in 6 term-pregnant guinea pigs. Plasma, brain, heart and liver samples were obtained for bupivacaine analysis from newborns (n = 22) after spontaneous delivery. Liver bupivacaine concentrations were 2-3 times greater than those in the plasma, brain, and heart. A similar pattern of tissue concentrations was seen in a smaller number of newborns delivered by cesarean section. Liver bupivacaine concentration decreased with drug-delivery interval in littermates, while heart and brain concentrations showed no relationship with drug-delivery interval. Blood gases of newborns reflected acidosis, which may have influenced tissue drug concentrations. Under conditions of the study, bupivacaine concentrations in heart and brain, potential sites of bupivacaine action, were lower than those observed in a peripheral blood sample.
引用
收藏
页码:304 / 313
页数:10
相关论文
共 50 条
  • [41] Plasma concentrations of bupivacaine during continuous epidural anaesthesia in children
    Scherhag, A
    Kleemann, PP
    Vrana, S
    Stanek, A
    Dick, W
    ANAESTHESIST, 1998, 47 (03): : 202 - 208
  • [42] PLASMA BUPIVACAINE CONCENTRATIONS FOLLOWING LUMBAR EPIDURAL-ANESTHESIA IN CHILDREN
    EYRES, RL
    HASTINGS, C
    BROWN, TCK
    OPPENHEIM, RC
    ANAESTHESIA AND INTENSIVE CARE, 1986, 14 (02) : 131 - 134
  • [43] NEUROBEHAVIORAL RESPONSES AND DRUG CONCENTRATIONS IN NEWBORNS AFTER MATERNAL EPIDURAL ANESTHESIA WITH BUPIVACAINE
    SCANLON, JW
    OSTHEIMER, GW
    LURIE, AO
    BROWN, WU
    WEISS, JB
    ALPER, MH
    ANESTHESIOLOGY, 1976, 45 (04) : 400 - 405
  • [44] Repeated addition of fentanyl to epidural bupivacaine analgesia during labor. Clinical efficacy and plasma concentrations of fentanyl
    Vettermann, J
    Thomas, H
    Lischke, V
    Asskali, F
    ANAESTHESIST, 1996, 45 (05): : 428 - 436
  • [45] Maternal and neonatal effects of epidural sufentanil administration for labor analgesia
    Mandell, G
    Adler, L
    Ramanathan, S
    Malley, B
    ANESTHESIOLOGY, 1997, 87 (03) : A901 - A901
  • [47] Epidural anesthesia with bupivacaine, bupivacaine and fentanyl, or bupivacaine and sufentanil during intravenous administration of propofol for ovariohysterectomy in dogs
    Almeida, Tatiana F.
    Fantoni, Denise T.
    Mastrocinque, Sandra
    Tatarunas, Angelica C.
    Imagawa, Viviane H.
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2007, 230 (01): : 45 - 51
  • [50] Serum bupivacaine concentrations and transplacental transfer following repeated epidural administrations in term parturients during labour
    Decocq, G
    Brazier, M
    Hary, L
    Hubau, C
    Fortaine, MR
    Gondry, J
    Andrejak, M
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 1997, 11 (04) : 365 - 370