Fructose-selective calorimetric biosensor in flow injection analysis

被引:22
作者
Bhand, Sunil G. [1 ,2 ]
Soundararajan, Srimathi [1 ]
Surugiu-Warnmark, Ioana [1 ]
Milea, Jaqueline Simona [1 ]
Dey, Estera Szwajcer [1 ]
Yakovleva, Maria [1 ]
Danielsson, Bengt [1 ]
机构
[1] Lund Univ, Ctr Chem, S-22100 Lund, Sweden
[2] Birla Inst Technol & Sci Pilani, Chem Grp, Goa 403726, India
关键词
D-fructose; Fructose-6-phosphate-kinase; Hexokinase; Enzyme thermistor; Immobilised enzymes; Flow injection analysis; AMPEROMETRIC BIOSENSOR; ENZYME ELECTRODE; GLUCOSE; DEHYDROGENASE; SUCROSE; POLYPYRROLE; MEMBRANE; BINDING; MATRIX;
D O I
10.1016/j.aca.2010.01.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly selective, interference free biosensor for the measurement of fructose in real syrup samples was developed. The assay is based on the phosphorylation of D(-)fructose to fructose-6-phosphate by hexokinase and subsequent conversion of fructose-6-phosphate to fructose-1,6-biphosphate by fructose-6-phosphate-kinase. The heat liberated in the second reaction is monitored using an enzyme thermistor. The major advantages of this biosensor are rapid and selective measurement of fructose without the need to eliminate glucose and inexpensive FIA-based, mediator-free calorimetric measurement suitable for regular fructose analysis. This method was optimised for parameters, such as pH, ionic strength, interference, operational stability and shelf life. Good and reproducible linearity (0.5-6.0 mM) with a detection limit of 0.12 mM was obtained. Fructose determination in commercial syrup samples and spiked samples confirmed the reliability of this set-up and technique. The biosensor gave reproducible results with good overall stability for continuous measurements over a period of three months besides a useful shelf life of six months. The method could be used for routine fructose monitoring in food samples. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:13 / 18
页数:6
相关论文
共 35 条
[1]   A SIMPLE AND RAPID COLORIMETRIC METHOD FOR LACTOSE DETERMINATION IN MILK [J].
ABULEHIA, IH .
FOOD CHEMISTRY, 1987, 24 (03) :233-240
[2]   A tri-enzyme electrode probe for the sequential determination of fructose and glucose in the same sample [J].
Antiochia, R ;
Palleschi, G .
ANALYTICAL LETTERS, 1997, 30 (04) :683-697
[3]   New ways of enzymatic two-substrate determinations in flow injection systems [J].
Becker, TM ;
Schmidt, HL .
ANALYTICA CHIMICA ACTA, 2000, 421 (01) :7-18
[4]  
BELL L, 1987, J AM DIET ASSOC, V87, P721
[5]   MULTIPURPOSE ELECTRODE WITH DIFFERENT ENZYME-SYSTEMS BOUND TO COLLAGEN FILMS [J].
BERTRAND, C ;
COULET, PR ;
GAUTHERON, DC .
ANALYTICA CHIMICA ACTA, 1981, 126 (MAY) :23-34
[6]   An integrated bienzyme glucose oxidase-fructose dehydrogenase-tetrathiafulvalene-3-mercaptopropionic acid-gold electrode for the simultaneous determination of glucose and fructose [J].
Campuzano, S ;
Loaiza, SA ;
Pedrero, M ;
de Villena, FJM ;
Pingarrón, JM .
BIOELECTROCHEMISTRY, 2004, 63 (1-2) :199-206
[7]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[8]  
DORNELLES L, 2002, FOOD CHEM, V77, P237
[9]   A new amperometric biosensor for fructose using a carbon paste electrode modified with silica gel coated with Meldola's Blue and fructose 5-dehydrogenase [J].
Garcia, CAB ;
Neto, GD ;
Kubota, LT ;
Grandin, LA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 418 (1-2) :147-151
[10]   New fructose biosensors utilizing a polypyrrole film and D-fructose 5-dehydrogenase immobilized by different processes [J].
Garcia, CAB ;
Neto, GD ;
Kubota, LT .
ANALYTICA CHIMICA ACTA, 1998, 374 (2-3) :201-208