Application of an EMG interference filtering method to dynamic ECGs based on an adaptive wavelet-Wiener filter and adaptive moving average filter

被引:23
作者
Li, Yurong [1 ]
Su, Zhichao [1 ]
Chen, Kai [1 ]
Zhang, Wenxuan [1 ]
Du, Min [2 ]
机构
[1] Fuzhou Univ, Coll Elect Engn & Automat, Fuzhou 350108, Fujian, Peoples R China
[2] Fuzhou Univ, Fujian Key Lab Med Instrumentat & Pharmaceut Tech, Fuzhou 350108, Fujian, Peoples R China
关键词
ECG denoising; Adaptive wavelet-Wiener filter; Moving average filter; SNR; GENETIC ALGORITHM;
D O I
10.1016/j.bspc.2021.103344
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In dynamic ECG signals, EMG interference is a common type of noise and overlaps with the ECG signal spectrum. Herein, we propose an EMG-filtering method that combines an adaptive wavelet-Wiener filter and an adaptive moving average filter. First, the R-peaks detection method is used to divide the signal into individual heartbeats, and wavelet threshold processing is used to evaluate signal-to-noise ratio. The wavelet-Wiener filter's parameters are then set adaptively according to the SNR, and the resulting adaptive wavelet-Wiener filter is applied to each heartbeat. Next, the low frequency components between two heartbeats are windowed to calculate standard deviation, and the order of the moving average filter is set adaptively according to the estimated SNR and standard deviation. Finally, a moving average filter is applied to the low frequency components to filter residual EMG noise. Before and after applying the moving average filter, splicing and discarding are performed on both sides of the low frequency components, effectively preventing distortion at the transition between the high and low frequency components. We evaluated the proposed method's performance using different ECG databases, including arrhythmia and dynamic ECG signals with motion artifacts, and compared its performance with that of other methods. Experimental results show that the proposed method can significantly improve SNR and effectively preserve clinical information, especially in environments with severe noise. The proposed method utilizes the advantages of both applied techniques to reduce the noise in ECG signals with minimal distortion and can be used as an effective tool for denoising ECG signals.
引用
收藏
页数:15
相关论文
共 22 条
[1]  
[Anonymous], The MT-BIH Noise Stress Test Database
[2]  
[Anonymous], 2008, Am. J. Appl. Sci.
[3]  
[Anonymous], MIT-BIH Normal Sinus Rhythm Database
[4]   ECG signal enhancement using S-Transform [J].
Ari, Samit ;
Das, Manab Kumar ;
Chacko, Anil .
COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (06) :649-660
[5]   ECG signal denoising and baseline wander correction based on the empirical mode decomposition [J].
Blanco-Velasco, Manuel ;
Weng, Binwei ;
Barner, Kenneth E. .
COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (01) :1-13
[6]  
Chand R., 2010, FPGA implementation of fast FIR low pass filter for EMG removal from ECG signal, P1, DOI 10.1109/ ICPCES.2010.5698652
[7]   Genetic algorithm and wavelet hybrid scheme for ECG signal denoising [J].
El-Dahshan, El-Sayed A. .
TELECOMMUNICATION SYSTEMS, 2011, 46 (03) :209-215
[8]   A multiresolution time-dependent entropy method for QRS complex detection [J].
Farashi, Sajjad .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2016, 24 :63-71
[9]  
Gotchev A, 2002, INT CONF ACOUST SPEE, P3872
[10]   An Adaptive Kalman Filter Bank for ECG Denoising [J].
Hesar, Hamed Danandeh ;
Mohebbi, Maryam .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (01) :13-21